Spatial and volumetric comparison of liver tumors on CT and MR using finite element based deformable image registration

被引:0
|
作者
Dawson, L [1 ]
Voroney, J [1 ]
Eccles, C [1 ]
Haider, M [1 ]
Brock, K [1 ]
机构
[1] Princess Margaret Hosp, Toronto, ON M4X 1K9, Canada
关键词
D O I
10.1118/1.1997432
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the spatial and volumetric differences in liver tumor definition based on triphasic IV contrast CT and Gadolinium contrast MR. Method and Materials: Changes in patient and liver position and differences in CT and MR imaging make an accurate comparison of tumor representation challenging, as deformation of the liver occurs. A deformable registration method has been developed to generate geometrically resolved views of the different image sets using finite element modeling to take advantage of the biomechanical relationship between the anatomical representations on each modality. The liver and liver tumors are contoured on the CT and MR, using a treatment planning system. A guided surface projection method is used to identify and account for the geometric discrepancies of the liver, allowing a direct comparison of the MR and CT tumors. Results: Triphasic CT and Gadolinium MR images were obtained at end exhale. Differences in tumor volume and center of mass and in the surface area differing by greater than 3 mm in spatial position (PSA3) were measured for patients with liver metastases, cholangiocarcinoma and hepatoma. The tumor comparisons were done following registration of the liver to resolve geometric discrepancies. The average tumor volume change was 52% (19–121%). The average center of mass change was 0.4 cm (0.1–0.6 cm). The average PSA3 was 49% (28–60%). Initial results show that MR GTV was larger then CT GTV in patients with hepatoma, smaller in cholangiocarcinoma and variable in metastases. Conclusion: Deformable image registration improves the spatial correlation of the MR and CT defined liver GTVs compared to rigid body registration alone. This deformable image registration method preserves the spatial integrity of the tumor, while resolving the geometric differences between the MR and CT liver. Conflict of Interest: Research supported in part by Varian Medical Systems. LD is an ASCO career development award recipient. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1894 / 1895
页数:2
相关论文
共 50 条
  • [1] Comparison of liver metastases volumes on CT, MR and FDG PET imaging to pathological resection using deformable image registration
    Dawson, L. A.
    Brock, K. K.
    Moulton, C.
    Moseley, J.
    Ahmed, S.
    Guindi, M.
    Gallimer, S.
    Haider, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S68 - S68
  • [2] Finite Element-Based Deformable Image Registration of Lung and Heart
    Penjweini, R.
    Kim, M.
    Zhu, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3398 - 3398
  • [3] Imaging response assessment using finite element model-based deformable image registration: Application to liver disease
    Brock, KK
    Dawson, LA
    Hawkins, M
    Sharpe, MB
    Moseley, J
    Jaffray, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S140 - S141
  • [4] Clinical feasibility of MR-assisted CT-based cervical brachytherapy using MR-to-CT deformable image registration
    Dyer, Brandon A.
    Yuan, Zilong
    Qiu, Jianfeng
    Shi, Liting
    Wright, Cari
    Benedict, Stanley H.
    Valicenti, Richard
    Mayadev, Jyoti S.
    Rong, Yi
    [J]. BRACHYTHERAPY, 2020, 19 (04) : 447 - 456
  • [5] Volume Based Comparison of Deformable Image Registration Algorithms Using Spatial Discrepancy Volume Histograms
    Fatyga, M.
    Dogan, N.
    Wijesooriya, K.
    Sleeman, W.
    Zhang, B.
    Christensen, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [6] Registration error of the liver CT using deformable image registration of MIM Maestro and Velocity AI
    Nobuyoshi Fukumitsu
    Kazunori Nitta
    Toshiyuki Terunuma
    Toshiyuki Okumura
    Haruko Numajiri
    Yoshiko Oshiro
    Kayoko Ohnishi
    Masashi Mizumoto
    Teruhito Aihara
    Hitoshi Ishikawa
    Koji Tsuboi
    Hideyuki Sakurai
    [J]. BMC Medical Imaging, 17
  • [7] Registration error of the liver CT using deformable image registration of MIM Maestro and Velocity AI
    Fukumitsu, Nobuyoshi
    Nitta, Kazunori
    Terunuma, Toshiyuki
    Okumura, Toshiyuki
    Numajiri, Haruko
    Oshiro, Yoshiko
    Ohnishi, Kayoko
    Mizumoto, Masashi
    Aihara, Teruhito
    Ishikawa, Hitoshi
    Tsuboi, Koji
    Sakurai, Hideyuki
    [J]. BMC MEDICAL IMAGING, 2017, 17
  • [8] Reducing uncertainties in volumetric image based deformable organ registration
    Liang, J
    Yan, D
    [J]. MEDICAL PHYSICS, 2003, 30 (08) : 2116 - 2122
  • [9] Finite Element-Based Deformable Image Registration of Pleural Cavity for Photodynamic Therapy
    Penjweini, R.
    Zhu, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3290 - 3290
  • [10] Evaluation of whole-body MR to CT deformable image registration
    Akbarzadeh, A.
    Gutierrez, D.
    Baskin, A.
    Ay, M. R.
    Ahmadian, A.
    Alam, N. Riahi
    Loevblad, K. O.
    Zaidi, H.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 238 - 253