An investigation of surface dose changes for therapeutic kilovoltage X-ray beams with underlying lead shielding

被引:0
|
作者
Hill, R
Healy, B
Holloway, L
Baldock, C
机构
[1] Liverpool Hosp, Sydney, NSW, Australia
[2] Univ Sydney, Inst Med Phys, Sydney, NSW 2006, Australia
[3] Princess Alexandra Hosp, Brisbane, Qld 4102, Australia
关键词
D O I
10.1118/1.1997862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The effect on surface dose from underlying lead shielding in water was investigated for therapeutic kilovoltage x‐ray beams by experimental and Monte Carlo methods. Method and Materials: A Farmer type ionisation chamber was used to measure the surface dose in a water phantom for x‐ray beams with energies from 75 to 135 kVp. A 5 mm thick lead sheet was positioned at various depths below the surface. The surface dose ratio was calculated by comparison with the surface dose with no lead sheet present. A Monte Carlo model of the x‐ray beam and the phantom was generated using the EGSnrcMP code (V4.2). The initial energy spectrum was determined using an empirical method and verified by calculation of depth dose data. The dose was scored in a 1 mm thick slab at the phantom surface. The change in surface dose was calculated as a function of depth to the lead and compared to measured data. Results: The reduction in surface dose was a function of x‐ray beam energy, beam area and the depth of water to the lead. As the depth of water to the lead sheet decreased, there was a reduction in the surface dose. With the 8 cm diameter applicator and 1 cm depth of water to the lead, the surface dose ratio was 0.918 for the 75 kVp x‐ray beam and 0.890 for the 100 kVp x‐ray beam. For the smaller applicators, there was less reduction in the surface dose ratios. Surface dose ratios calculated by the EGSnrcMP code were in good agreement with measured data, with a maximum deviation of 1.2%. Conclusion: The surface dose for kilovoltage x‐ray beams is reduced when lead is underlying in the phantom. The Monte Carlo results indicate the model is sufficiently accurate to predict changes in the surface dose. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1991 / 1991
页数:1
相关论文
共 50 条
  • [1] An investigation of dose changes for therapeutic kilovoltage x-ray beams with underlying lead shielding
    Hill, Robin
    Healy, Brendan
    Holloway, Lois
    Baldock, Clive
    MEDICAL PHYSICS, 2007, 34 (07) : 3045 - 3053
  • [2] SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS
    Araki, F.
    Umeno, S.
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (02) : 124 - 131
  • [3] Broad beam attenuation measurements in lead in kilovoltage X-ray beams
    Akber, Syed F.
    Das, Indra J.
    Kehwar, Than S.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (03): : 197 - 202
  • [4] Monte Carlo Study of NanoDot OSED for Surface Dose Measurements in Kilovoltage X-Ray Beams
    Araki, F.
    MEDICAL PHYSICS, 2018, 45 (06) : E609 - E609
  • [5] Determination of the surface dose of a water phantom using a semiconductor detector for diagnostic kilovoltage x-ray beams
    Tanabe, Ryuki
    Araki, Fujio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 198 - 204
  • [6] Absorbed dose conversion factors for therapeutic kilovoltage and megavoltage x-ray beams calculated by the Monte Carlo method
    Knight, RT
    MEDICAL PHYSICS, 1997, 24 (02) : 336 - 336
  • [7] Increase of the surface dose in kilovoltage x-ray therapy beams due to a thin layer of plastic wrap.
    Blais, N
    David, S
    Mondat, M
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2920 - 2923
  • [8] The dosimetry of eye shields for kilovoltage X-ray beams
    Wang, D.
    Sobolewski, M.
    Hill, R.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (04) : 491 - 495
  • [9] The dosimetry of eye shields for kilovoltage X-ray beams
    D. Wang
    M. Sobolewski
    R. Hill
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 491 - 495
  • [10] Stereotactic breast irradiation with kilovoltage x-ray beams
    Garnica-Garza, H. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 983 - 995