Label-free cytosensing of cancer cells based on the interaction between protein and an electron-transfer carbohydrate-mimetic peptide

被引:13
|
作者
Sugawara, Kazuharu [1 ]
Kuramitz, Hideki [2 ]
Kadoya, Toshihiko [1 ]
机构
[1] Maebashi Inst Technol, Maebashi, Gunma 3710816, Japan
[2] Univ Toyama, Grad Sch Sci & Engn Res, Dept Environm Biol & Chem, Toyama 9308555, Japan
关键词
Electron-transfer peptide; Carbohydraye-mimetic peptide; Protein-modified magnetic bead; K562; cell; HepG2; ELECTROCHEMICAL APTAMER CYTOSENSOR; SURFACE-PLASMON RESONANCE; SIGNAL AMPLIFICATION; LECTIN; NANOPARTICLES; RECEPTOR; ADHESION; GLYCANS; EXPRESSION; BIOSENSOR;
D O I
10.1016/j.aca.2018.08.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We used an electron-transfer carbohydrate-mimetic peptide (YYYYC) to construct an electrochemical cytosensing system. Magnetic beads were modified with either asialofetuin (ASF) or soybean agglutinin (SBA) to evaluate the effect on cell sensing. Because SBA binds to the galactose residue that exists at the terminals of the carbohydrate chains in ASF, the target protein was accumulated on the protein magnetic beads. SBA is an example of N-acetylgalactosamine- and galactose-binding proteins that readily combine with YYYYC. When the peptides and protein-immobilized beads competed for a target protein, the peak current of the peptides changed according to the concentration of the protein at the 10(-12) M level. Next, human myeloid leukemia cells (K562 cell) were measured using the peptide and the carbohydrate chains on the cell surface that recognize SBA. The electrode response was linear to the number of K562 cells and ranged from 1.0 x 10(2) to 5.0 x 10(3) cells mL(-1). In addition, detection of a human liver cancer cell (HepG2 cell) was carried out using interactions with the peptide, the ASF receptors in HepG2 cells, and the carbohydrate chains of ASF. The peak currents were proportional and ranged between 5.0 x 101 and 1.5 x 10(3) cells mL(-1). When the values estimated from an electrochemical process were compared with those obtained by ELISA, the results were within the acceptable range of measurement error. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:166 / 176
页数:11
相关论文
共 50 条
  • [1] Magnetic beads modified with an electron-transfer carbohydrate-mimetic peptide for sensing of a galactose-dependent protein
    Sugawara, Kazuharu
    Kadoya, Toshihiko
    Kuramitz, Hideki
    ANALYTICA CHIMICA ACTA, 2018, 1001 : 158 - 167
  • [2] Voltammetric Sensing of Soybean Agglutinin Using an Electrode Modified with Electron-Transfer, Carbohydrate-Mimetic/Cross-Linker-Peptide-Collagen Film
    Ishizaki, Sora
    Kuramitz, Hideki
    Sugawara, Kazuharu
    ELECTROANALYSIS, 2022, 34 (03) : 464 - 473
  • [3] Label-free electrochemical impedance spectroscopy biosensor for direct detection of cancer cells based on the interaction between carbohydrate and lectin
    Hu, Yaofang
    Zuo, Peng
    Ye, Bang-Ce
    BIOSENSORS & BIOELECTRONICS, 2013, 43 : 79 - 83
  • [4] A silicon-based peptide biosensor for label-free detection of cancer cells
    Martucci, Nicola M.
    Rea, Ilaria
    Ruggiero, Immacolata
    Terracciano, Monica
    De Stefano, Luca
    Migliaccio, Nunzia
    Dardano, Principia
    Arcari, Paolo
    Rendina, Ivo
    Lamberti, Annalisa
    OPTICAL SENSORS 2015, 2015, 9506
  • [5] A label-free electrochemical immunoassay for IgG detection based on the electron transfer
    Qiu, Li-Ping
    Wang, Cun-Chang
    Hu, Peng
    Wu, Zai-Sheng
    Shen, Guo-Li
    Yu, Ru-Qin
    TALANTA, 2010, 83 (01) : 42 - 47
  • [6] Characterization of the interaction between N-terminal annexin A1 residue and tumor-targeting carbohydrate-mimetic IF7 peptide
    Nonaka, Motohiro
    Sasai, Toshio
    Nagaoka, Masato
    Fukuda, Michiko N.
    GLYCOBIOLOGY, 2015, 25 (11) : 1294 - 1294
  • [7] Label-Free Optical Imaging of the Electron Transfer in Single Live Microbial Cells
    Liu, Yi-Nan
    Lv, Zhen-Ting
    Lv, Wen-Li
    Liu, Dong-Feng
    Liu, Xian-Wei
    NANO LETTERS, 2023, 23 (02) : 558 - 566
  • [8] A label-free electrochemical biosensor for detection of HIV related gene based on interaction between DNA and protein
    Guo, Yang
    Chen, JingHua
    Chen Guonan
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 184 : 113 - 117
  • [9] An ultrasensitive label-free immunoassay for C-reactive protein detection in human serum based on electron transfer
    Zhang, Xi
    Hu, Rong
    Zhang, Kunlei
    Bai, Ruyan
    Li, Delei
    Yang, Yunhui
    ANALYTICAL METHODS, 2016, 8 (32) : 6202 - 6207
  • [10] A label-free sensitive method for membrane protein detection based on aptamer and AgNCs transfer
    Liu, Zhenjun
    Chen, Wansong
    Han, Yajin
    Ouyang, Jiang
    Chen, Min
    Hu, Shengqiang
    Deng, Liu
    Liu, You-Nian
    TALANTA, 2017, 175 : 470 - 476