Legionella pneumonia due to exposure to 24-hour bath water contaminated by Legionella pneumophila serogroup-5

被引:16
|
作者
Mineshita, M
Nakamori, Y
Seida, Y
Hiwatashi, S
机构
[1] Mishuku Hosp, Dept Resp Med, Tokyo, Japan
[2] Mishuku Hosp, Dept Clin Lab, Tokyo, Japan
关键词
nursing home; pulsed-field gel electrophoresis; an outbreak of Legionella pneumonia;
D O I
10.2169/internalmedicine.44.662
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 79-year-old man was admitted to hospital from his nursing home for treatment of pneumonia, but died 7 days after admission. Legionella pneumonia was diagnosed after isolation of Legionella pneumophila serogroup-5 from sputum culture. The environment of the nursing home was investigated; only water specimens from the 24-hour bath were positive by culture for Legionella pneumophild serogroup-5. Subsequent analysis by pulsed-field gel electrophoresis revealed an identical pattern in isolates from both sputum culture and 24 hour bath water culture. Among 123 inpatients and staff of the nursing home, 17 were found to be seropositive for Legionella pneumophila serogroup-5.
引用
收藏
页码:662 / 665
页数:4
相关论文
共 24 条
  • [1] LEGIONELLA-PNEUMOPHILA SEROGROUP-5 INFECTIONS IN THE CAMBRIDGE AREA - A SEROLOGICAL SURVEY
    NAGINGTON, J
    WREGHITT, TG
    SMITH, DJ
    [J]. JOURNAL OF INFECTION, 1981, 3 (01) : 18 - 23
  • [2] A RAPID MICRO-AGGLUTINATION TECHNIQUE FOR THE DETECTION OF ANTIBODY TO LEGIONELLA-PNEUMOPHILA SEROGROUP-5
    CONSTANTINE, CE
    WREGHITT, TG
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1991, 34 (01) : 29 - 31
  • [3] Severe community-acquired pneumonia due to Legionella pneumophila serogroup 6
    Chen, CY
    Chen, KY
    Hsueh, PR
    Yang, PC
    [J]. JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2006, 105 (03) : 256 - 262
  • [4] RAPID DIAGNOSIS OF PNEUMONIA DUE TO LEGIONELLA-PNEUMOPHILA SEROGROUP-1
    KOHLER, RB
    WINN, WC
    GIROD, JC
    WHEAT, LJ
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1982, 146 (03): : 444 - 444
  • [5] Legionella pneumonia due to non-Legionella pneumophila serogroup 1: usefulness of the six-point scoring system
    Akihiro Ito
    Tadashi Ishida
    Yasuyoshi Washio
    Akio Yamazaki
    Hiromasa Tachibana
    [J]. BMC Pulmonary Medicine, 17
  • [6] Legionella pneumonia due to non-Legionella pneumophila serogroup 1: usefulness of the six-point scoring system
    Ito, Akihiro
    Ishida, Tadashi
    Washio, Yasuyoshi
    Yamazaki, Akio
    Tachibana, Hiromasa
    [J]. BMC PULMONARY MEDICINE, 2017, 17
  • [7] PNEUMONIA WITH PLEURAL EFFUSION DUE TO LEGIONELLA-PNEUMOPHILA SEROGROUP LANSING-3
    MARTIN, WT
    BOYLE, CAJ
    BERNARD, K
    WILLIAMS, KE
    CONLY, JM
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1995, 21 (02) : 101 - 103
  • [8] Outbreak of Legionnaires' disease on a cruise ship linked to spa-bath filter stones contaminated with Legionella pneumophila serogroup 5
    Kura, F
    Amemura-Maekawa, J
    Yagita, K
    Endo, T
    Ikeno, M
    Tsuji, H
    Taguchi, M
    Kobayashi, K
    Ishii, E
    Watanabe, H
    [J]. EPIDEMIOLOGY AND INFECTION, 2006, 134 (02): : 385 - 391
  • [9] Detection of specific IgM antibody in the investigation of an outbreak of pneumonia due to Legionella pneumophila serogroup 1
    de Ory, F
    Echevarría, JM
    Pelaz, C
    Téllez, A
    Mateo, MA
    López, J
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2000, 6 (02) : 64 - 68
  • [10] Fatal Nosocomial Legionella pneumophila Infection Due to Exposure to Contaminated Water From a Washbasin in a Hematology Unit
    Brulet, Alexandre
    Nicolle, Marie-Christine
    Giard, Marine
    Nicolini, Franck-Emmanuel
    Michallet, Mauricette
    Jarraud, Sophie
    Etienne, Jerome
    Vanhems, Philippe
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (11): : 1091 - 1093