Evaluation and minimisation of energy consumption in a medium-scale reverse osmosis brackish water desalination plant

被引:54
|
作者
Alsarayreh, Alanood A. [1 ]
Al-Obaidi, M. A. [2 ]
Al-Hroub, A. M. [3 ]
Patel, R. [1 ]
Mujtaba, I. M. [1 ]
机构
[1] Univ Bradford, Fac Engn & Informat, Dept Chem Engn, Bradford BD7 1DP, W Yorkshire, England
[2] Middle Tech Univ, Tech Inst Baquba, Dayala, Iraq
[3] Arab Potash Co, Energy & Water Directorate, Amman, Jordan
关键词
Reverse osmosis; Modelling; Minimisation of energy consumption; Brackish water desalination; OF-THE-ART; DRIVEN DESALINATION; COST OPTIMIZATION; PORE-SIZE; RECOVERY; SIMULATION; TEMPERATURE; SYSTEM; PERFORMANCE; DESIGN;
D O I
10.1016/j.jclepro.2019.119220
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Reverse Osmosis (RO) process has been expansively used in water treatment as a result of its low energy consumption compared to thermal distillation processes, leading to reduced overall water production cost. Evaluation and minimisation of energy consumption (expressed in kWh/m(3) of fresh water production) in a medium-scale spiral wound brackish water RO (BWRO) desalination plant of the Arab Potash Company (APC) are the main aims of this research. The model developed earlier by the authors has been integrated to simulate the process and achieve the main aims. Energy consumption calculations of low salinity BWRO desalination plant, with and without an energy recovery device, have been carried out using the gPROMS software suite. In other words, this research evaluated the impact of adding an energy recovery device on the RO process energy consumption of the APC, which is introduced for the first time. Also, the effects of several operating conditions of BWRO process include the feed flow rate, pressure and temperature on the performance indicators, which include the energy consumption and total plant recovery at different energy recovery device efficiencies, were studied. The simulation results showed that the total energy consumption could be reduced at low values of feed flow rates and pressures and high values of temperatures. More importantly, there is an opportunity to reduce the total energy consumption between 47% and 53.8% compared to the one calculated for the original design without an energy recovery device. (c) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Optimisation of Energy Consumption in a Medium-scale Reverse Osmosis Brackish Water esalination Planty
    Alsarayreh, Alanood A.
    Al-Obaidi, M. A.
    Al-Hroub, A. M.
    Patel, R.
    Mujtaba, I. M.
    [J]. 30TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PTS A-C, 2020, 48 : 373 - 378
  • [2] Performance evaluation of a medium-scale industrial reverse osmosis brackish water desalination plant with different brands of membranes. A simulation study
    Alsarayreh, Alanood A.
    Al-Obaidi, Mudhar A.
    Farag, Shekhah K.
    Patel, Raj
    Mujtaba, Iqbal M.
    [J]. DESALINATION, 2021, 503
  • [3] Experimental study of the specific energy consumption for brackish water desalination by reverse osmosis
    Avlonitis, S. A.
    Avlonitis, D. A.
    Panagiotidis, Th
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2012, 36 (01) : 36 - 45
  • [4] Energy Consumption of Brackish Water Desalination: Identifying the Sweet Spots for Electrodialysis and Reverse Osmosis
    Patel, Sohum K.
    Biesheuvel, P. Maarten
    Elimelech, Menachem
    [J]. ACS ES&T ENGINEERING, 2021, 1 (05): : 851 - 864
  • [5] Performance analysis of a medium-sized industrial reverse osmosis brackish water desalination plant
    Al-Obaidi, M. A.
    Alsarayreh, A. A.
    Al-Hroub, A. M.
    Alsadaie, S.
    Mujtaba, I. M.
    [J]. DESALINATION, 2018, 443 : 272 - 284
  • [6] Optimal plant operation of brackish water reverse osmosis (BWRO) desalination
    Li, Mingheng
    [J]. DESALINATION, 2012, 293 : 61 - 68
  • [7] Economics and Energy Consumption of Brackish Water Reverse Osmosis Desalination: Innovations and Impacts of Feedwater Quality
    Pearson, Jeffrey L.
    Michael, Peter R.
    Ghaffour, Noreddine
    Missimer, Thomas M.
    [J]. MEMBRANES, 2021, 11 (08)
  • [8] Enhanced exergy analysis of a full-scale brackish water reverse osmosis desalination plant
    Fellaou, S.
    Ruiz-Garcia, A.
    Gourich, B.
    [J]. DESALINATION, 2021, 506
  • [9] Desalination of brackish water by nanofiltration and reverse osmosis
    Mohsen, MS
    Jaber, JO
    Afonso, MD
    [J]. DESALINATION, 2003, 157 (1-3) : 167 - 167
  • [10] Performance Evaluation of Reverse Osmosis Brackish Water Desalination Plant with Different Recycled Ratios of Retentate
    Alsarayreh, A. A.
    Al-Obaidi, M. A.
    Al-Liroub, A. M.
    Patel, R.
    Mujtaba, I. M.
    [J]. 29TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PT A, 2019, 46 : 181 - 186