Comparison of silver and molybdenum microfocus X-ray sources for single-crystal structure determination

被引:2835
|
作者
Krause, Lennard [1 ]
Herbst-Irmer, Regine [1 ]
Sheldrick, George M. [1 ]
Stalke, Dietmar [1 ]
机构
[1] Univ Gottingen, Inst Anorgan Chem, D-37077 Gottingen, Germany
来源
基金
新加坡国家研究基金会;
关键词
microfocus X-ray sources; single-crystal structure determination; absorption correction; DARWIN TRANSFER EQUATIONS; ABSORPTION CORRECTION; SPHERICAL CRYSTALS; FOCUSING OPTICS; CRYSTALLOGRAPHY; REFINEMENT; LIMIT; EXTINCTION; VALIDITY; ERRORS;
D O I
10.1107/S1600576714022985
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The quality of diffraction data obtained using silver and molybdenum microsources has been compared for six model compounds with a wide range of absorption factors. The experiments were performed on two 30W air-cooled Incoatec I mu S microfocus sources with multilayer optics mounted on a Bruker D8 goniometer with a SMART APEX II CCD detector. All data were analysed, processed and refined using standard Bruker software. The results show that AgK radiation can be beneficial when heavy elements are involved. A numerical absorption correction based on the positions and indices of the crystal faces is shown to be of limited use for the highly focused microsource beams, presumably because the assumption that the crystal is completely bathed in a (top-hat profile) beam of uniform intensity is no longer valid. Fortunately the empirical corrections implemented in SADABS, although originally intended as a correction for absorption, also correct rather well for the variations in the effective volume of the crystal irradiated. In three of the cases studied (two Ag and one Mo) the final SHELXL R1 against all data after application of empirical corrections implemented in SADABS was below 1%. Since such corrections are designed to optimize the agreement of the intensities of equivalent reflections with different paths through the crystal but the same Bragg 2 angles, a further correction is required for the 2 dependence of the absorption. For this, SADABS uses the transmission factor of a spherical crystal with a user-defined value of r (where is the linear absorption coefficient and r is the effective radius of the crystal); the best results are obtained when r is biased towards the smallest crystal dimension. The results presented here suggest that the IUCr publication requirement that a numerical absorption correction must be applied for strongly absorbing crystals is in need of revision.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 50 条
  • [1] MICROFOCUS X-RAY MAPPING OF FATIGUE PROCESSES IN SINGLE-CRYSTAL COPPER
    WAYSON, AR
    [J]. EXPERIMENTAL MECHANICS, 1968, 8 (08) : 369 - &
  • [2] A comparison of a microfocus X-ray source and a conventional sealed tube for crystal structure determination
    Schulz, Thomas
    Meindl, Kathrin
    Leusser, Dirk
    Stern, Daniel
    Graf, Juergen
    Michaelsen, Carsten
    Ruf, Michael
    Sheldrick, George M.
    Stalke, Dietmar
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2009, 42 : 885 - 891
  • [3] A SINGLE-CRYSTAL X-RAY STRUCTURE DETERMINATION OF NEPTUNIUM TETRACHLORIDE
    SPIRLET, MR
    JEMINE, X
    GOFFART, J
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 1995, 216 (02) : 269 - 271
  • [4] THE SINGLE-CRYSTAL X-RAY STRUCTURE DETERMINATION OF COPPER VANCOMYCIN
    EGGLESTON, DS
    SHUI, XQ
    WEBB, RL
    MCARDLE, JV
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 87 - INOR
  • [5] Single-crystal X-ray structure determination of neptunium tetrachloride
    [J]. Spirlet, Marie-Rose, 1600, Elsevier Science S.A., Lausanne, Switzerland (216):
  • [6] SINGLE-CRYSTAL X-RAY STRUCTURE DETERMINATION OF ETHYLENE AT 85 K
    VANNES, GJH
    VOS, A
    [J]. ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE, 1977, 33 (MAY13): : 1653 - 1654
  • [7] STRUCTURE OF MOLYBDENUM PENTACHLORIDE-GRAPHITE BY SINGLE-CRYSTAL ELECTRON AND X-RAY DIFFRACTION
    JOHNSON, AWS
    [J]. ACTA CRYSTALLOGRAPHICA, 1967, 23 : 770 - &
  • [8] Comparative crystal structure determination of griseofulvin: Powder X-ray diffraction versus single-crystal X-ray diffraction
    Pan QingQing
    Guo Ping
    Duan Jiong
    Cheng Qiang
    Li Hui
    [J]. CHINESE SCIENCE BULLETIN, 2012, 57 (30): : 3867 - 3871
  • [10] MICROFOCUS X-RAY SOURCE IN BERG-BARRETT SINGLE-CRYSTAL SUBSTRUCTURE EXAMINATION
    ZASIMCHUK, IK
    FOMIN, AV
    [J]. INDUSTRIAL LABORATORY, 1977, 43 (12): : 1695 - 1697