Randomized Study of Vaginoscopy and H Pipelle vs Traditional Hysteroscopy and Standard Pipelle

被引:13
|
作者
Ngu, Siew-Fei [1 ]
Cheung, Vincent Y. T. [1 ]
Pun, Ting-Chung [1 ]
机构
[1] Univ Hong Kong, Dept Obstet & Gynecol, Queen Mary Hosp, Hong Kong, Hong Kong, Peoples R China
关键词
Hysteroscopy; Vaginoscopy; Pipelle endometrial sampler; OUTPATIENT HYSTEROSCOPY; DIAGNOSTIC HYSTEROSCOPY; OFFICE HYSTEROSCOPY; PAIN;
D O I
10.1016/j.jmig.2011.12.007
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: To compare the use of vaginoscopic vs traditional hysteroscopy in evaluation of the endometrial cavity. Design: Prospective, randomized, single blinded, clinical trial (Canadian Task Force classification I). Setting: University-affiliated hospital in Hong Kong. Patients: Ninety women scheduled to undergo diagnostic hysteroscopy without anesthesia. Interventions: Women were randomized to undergo either vaginoscopic hysteroscopy using the H Pipelle for endometrial sampling (n = 45) or traditional hysteroscopy using the standard Pipelle (n = 45). Both procedures were performed without anesthesia and using a rigid 4.5-mm hysteroscope. Main outcome measures analyzed were pain scores using a 10-point visual analog scale during hysteroscopy, endometrial biopsy, and overall pain score of the procedure, success and duration of each procedure, and adequacy of the endometrial sample obtained. Measurements and Main Results: The success rates for vaginoscopic and traditional hysteroscopy were 93.33% and 100%, respectively (p = .24). There was no significant difference in the mean pain score and procedure duration between the 2 hysteroscopic approaches. Endometrial sampling using the H Pipelle was significantly quicker by about 45 seconds compared with use of the standard Pipelle (mean [SD] duration, 1.46 [0.72] thin vs 2.20 [1.19] min, respectively; p = .001), with similar biopsy adequacy. Most women (95.5% in both approaches) found the procedure acceptable. There were no intraoperative or postoperative complications. Conclusions: Vaginoscopic and traditional hysteroscopic approaches are similar in safety, feasibility, and associated pain. Although the time needed to obtain an endometrial sample using the H Pipelle was quicker than with the standard Pipelle, there is no difference in overall procedure duration. Journal of Minimally Invasive Gynecology (2012) 19, 206-211 (C) 2012 AAGL. All rights reserved.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 50 条
  • [1] A prospective randomised study on vaginoscopy and H Pipelle versus traditional hysteroscopy and standard pipelle
    Ngu, S-F
    Cheung, V. Y. T.
    Pun, T-C
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2012, 119 : 202 - 202
  • [2] A randomised trial comparing the H Pipelle with the standard Pipelle for endometrial sampling at 'no-touch' (vaginoscopic) hysteroscopy
    Madari, S.
    Al-Shabibi, N.
    Papalampros, P.
    Papadimitriou, A.
    Magos, A.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2009, 116 (01) : 32 - 37
  • [3] A new device for "no touch" biopsy at "no touch" hysteroscopy: The H Pipelle
    Sardo, MDS
    Sharma, M
    Taylor, A
    Buck, L
    Magos, A
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (01) : 157 - 158
  • [4] An audit of using the H Pipelle for endometrial sampling at outpatient hysteroscopy and literature review comparison with the Pipelle de Cornier
    Dacco', Maria Diletta
    Moustafa, Mohsen
    Papoutsis, Dimitrios
    Georgantzis, Dimitrios
    Halmos, Gabor
    Magos, Adam
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2012, 165 (02) : 299 - 301
  • [5] Preoperative diagnosis of tumor grade and type in endometrial cancer by pipelle sampling and hysteroscopy: Results of a French study
    Phelippeau, Juliette
    Canlorbe, Geoffroy
    Bendifallah, Sofiane
    Naoura, Iptissem
    Lefevre, Marine
    Ballester, Marcos
    Darai, Emile
    [J]. SURGICAL ONCOLOGY-OXFORD, 2016, 25 (04): : 370 - 377
  • [6] Outcome comparison between vaginoscopy and standard hysteroscopy: A retrospective cohort study
    Tien, Chin-Tzu
    Li, Pei-Chen
    Ding, Dah-Ching
    [J]. JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2021, 84 (05) : 536 - 539
  • [7] The necessity of using tenaculum for endometrial sampling procedure with pipelle: a randomized controlled study
    Gulec, Umran Kucukgoz
    Khatib, Ghanim
    Guzel, Ahmet Baris
    Akil, Aybala
    Urunsak, Ibrahim Ferhat
    Ozgunen, Fatma Tuncay
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2014, 289 (02) : 349 - 356
  • [8] The necessity of using tenaculum for endometrial sampling procedure with pipelle: a randomized controlled study
    Umran Kucukgoz Gulec
    Ghanim Khatib
    Ahmet Baris Guzel
    Aybala Akil
    Ibrahim Ferhat Urunsak
    Fatma Tuncay Ozgunen
    [J]. Archives of Gynecology and Obstetrics, 2014, 289 : 349 - 356
  • [9] Endometrial biopsy: A pilot study of instrument used; Pipelle vs infant feeding tube
    Bhide, A.
    Gangji, A.
    Anyanwu, L.
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2007, 27 (08) : 838 - 839
  • [10] Diagnostic values of pipelle and standard curettage compared to hysterectomy pathology in postmenopausal bleeding: A comparative study
    Behnamfar, Fariba
    Arshad, Elham