Automatic Three-Dimensional Rib Centerline Extraction from CT Scans For Enhanced Visualization and Anatomical Context

被引:2
|
作者
Ramakrishnan, Sowmya [1 ]
Alvino, Christopher [2 ]
Grady, Leo [2 ]
Kiraly, Atilla [2 ]
机构
[1] Volt Workforce Solut Inc, Woodbridge, NJ USA
[2] Siemens Corp, Siemens Corp Res, Princeton, NJ 08540 USA
来源
关键词
Rib tracing; Kalman filter; chest CT; centerline extraction; SEGMENTATION;
D O I
10.1117/12.878283
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a complete automatic system to extract 3D centerlines of ribs from thoracic CT scans. Our rib centerline system determines the positional information for the rib cage consisting of extracted rib centerlines, spinal canal centerline, pairing and labeling of ribs. We show an application of this output to produce an enhanced visualization of the rib cage by the method of Kiraly et al., in which the ribs are digitally unfolded along their centerlines. The centerline extraction consists of three stages: (a) pre-trace processing for rib localization, (b) rib centerline tracing, and (c) post-trace processing to merge the rib traces. Then we classify ribs from non-ribs and determine anatomical rib labeling. Our novel centerline tracing technique uses the Random Walker algorithm to segment the structural boundary of the rib in successive 2D cross sections orthogonal to the longitudinal direction of the ribs. Then the rib centerline is progressively traced along the rib using a 3D Kalman filter. The rib centerline extraction framework was evaluated on 149 CT datasets with varying slice spacing, dose, and under a variety of reconstruction kernels. The results of the evaluation are presented. The extraction takes approximately 20 seconds on a modern radiology workstation and performs robustly even in the presence of partial volume effects or rib pathologies such as bone metastases or fractures, making the system suitable for assisting clinicians in expediting routine rib reading for oncology and trauma applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Automatic Carotid Centerline Extraction from Three-Dimensional Ultrasound Doppler Images
    Parrini, S.
    Zhang, L.
    Condino, S.
    Ferrari, V.
    Caramella, D.
    Ferrari, M.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5089 - 5092
  • [2] Three-Dimensional Coronary Artery Centerline Extraction and Cross Sectional Lumen Quantification from CT Angiography Images
    Cui, Hengfei
    Xia, Yong
    Zhang, Yanning
    INTELLIGENCE SCIENCE AND BIG DATA ENGINEERING: VISUAL DATA ENGINEERING, PT I, 2019, 11935 : 238 - 248
  • [3] Automatic centerline detection of small three-dimensional vessel structures
    Cheng, Yuanzhi
    Hu, Xin
    Wang, Yadong
    Wang, Jinke
    Tamura, Shinichi
    JOURNAL OF ELECTRONIC IMAGING, 2014, 23 (01)
  • [4] Using Three-Dimensional Cranial Scans to Teach Anatomical Variation
    Ganoe, Maria R.
    Lynch, Hannah L.
    Koons, Aaron W.
    Lambert, H. Wayne
    Zdilla, Matthew J.
    FASEB JOURNAL, 2018, 32 (01):
  • [5] A Learning Based Deformable Template Matching Method for Automatic Rib Centerline Extraction and Labeling in CT Images
    Wu, Dijia
    Liu, David
    Puskas, Zoltan
    Lu, Chao
    Wimmer, Andreas
    Tietjen, Christian
    Soza, Grzegorz
    Zhou, S. Kevin
    2012 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2012, : 980 - 987
  • [6] Enhanced Three-Dimensional Visualization of EEG Signals
    Gavrilescu, Marius
    Ungureanu, Florina
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [7] Three-dimensional analysis of ground glass opacities from helical CT scans
    Reeves, AP
    Kostis, WJ
    Yankelevitz, DF
    Henschke, CI
    RADIOLOGY, 2000, 217 : 384 - 384
  • [8] Three-dimensional segmentation of solitary pulmonary nodules from helical CT scans
    Kostis, WJ
    Reeves, AP
    Yankelevitz, DF
    Henschke, CI
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 203 - 207
  • [9] Intrathoracic rib demonstrated by helical CT with three-dimensional reconstruction
    Laufer, L
    Schulman, H
    Hertzanu, Y
    EUROPEAN RADIOLOGY, 1999, 9 (01) : 60 - 61
  • [10] Intrathoracic rib demonstrated by helical CT with three-dimensional reconstruction
    L. Laufer
    H. Schulman
    Y. Hertzanu
    European Radiology, 1999, 9 : 60 - 61