Head-to-Head Comparisons of Carbon Fiber Microelectrode Coatings for Sensitive and Selective Neurotransmitter Detection by Voltammetry

被引:78
|
作者
Singh, Yogesh S. [1 ,2 ,3 ]
Sawarynski, Lauren E. [4 ]
Dabiri, Pasha D. [1 ,2 ]
Choi, Wonwoo R. [1 ,2 ]
Andrews, Anne M. [1 ,2 ,5 ]
机构
[1] Univ Calif Los Angeles, Semel Inst Neurosci & Human Behav, David Geffen Sch Med, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Calif NanoSyst Inst, Los Angeles, CA 90095 USA
[3] Penn State Univ, Dept Chem, University Pk, PA 16802 USA
[4] Penn State Univ, Dept Bioengn, University Pk, PA 16802 USA
[5] Penn State Univ, Dept Vet & Biomed Sci, University Pk, PA 16802 USA
关键词
SCAN CYCLIC VOLTAMMETRY; ELECTRON-TRANSFER KINETICS; SUBSECOND DOPAMINE RELEASE; IN-VIVO ELECTROCHEMISTRY; SEROTONIN UPTAKE; BIOLOGICAL-SYSTEMS; RAT STRIATUM; DIAMOND MICROELECTRODES; MICRODIALYSIS PROBES; UPTAKE INHIBITORS;
D O I
10.1021/ac2011729
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Voltammetry is widely used to investigate neuro-transmission and other biological processes but is limited by poor chemical selectivity and fouling of commonly used carbon fiber microelectrodes (CFMs). We performed direct comparisons of three key coating materials purported to impart selectivity and fouling resistance to electrodes: Nafion, base-hydrolyzed cellulose acetate (BCA), and fibronectin. We systematically evaluated the impact on a range of electrode parameters. Fouling due to exposure to brain tissue was investigated using an approach that minimizes the use of animals while enabling evaluation of statistically significant populations of electrodes. We find that BCA is relatively fouling-resistant. Moreover, detection at BCA-coated CFMs can be tuned by altering hydrolysis times to minimize the impact on sensitivity losses while maintaining fouling resistance. Fibronectin coating is associated with moderate losses in sensitivity after coating and fouling. Nafion imparts increased sensitivity for dopamine and norepinephrine but not serotonin, as well as the anticipated selectivity for cationic neurotransmitters over anionic metabolites. Although Nafion has been suggested to resist fouling, both dip-coating and electrodeposition of Nafion are associated with substantial fouling, similar to levels observed at bare electrodes after exposure to brain tissue. Direct comparisons of these coatings identified unique electroanalytical properties of each that can be used to guide selection tailored to the goals and environment of specific studies.
引用
收藏
页码:6658 / 6666
页数:9
相关论文
共 24 条
  • [1] Studies of selective ion-sensitive microelectrode technique for the detection of neurotransmitter in vivo
    Zheng, XX
    Sun, YH
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2862 - 2863
  • [2] Fabrication of Graphene Coated Carbon Fiber Microelectrode for Highly Sensitive Detection Application
    Bai, Jie
    Wang, Xiaojuan
    Meng, Yuning
    Zhang, Hui-Min
    Qu, Liangti
    [J]. ANALYTICAL SCIENCES, 2014, 30 (09) : 903 - 909
  • [3] Fabrication of Graphene Coated Carbon Fiber Microelectrode for Highly Sensitive Detection Application
    Jie Bai
    Xiaojuan Wang
    Yuning Meng
    Hui-Min Zhang
    Liangti Qu
    [J]. Analytical Sciences, 2014, 30 : 903 - 909
  • [4] A nickel nanoparticle/carbon nanotube-modified carbon fiber microelectrode for sensitive insulin detection
    Longsheng Lu
    Linsheng Liang
    Yingxi Xie
    Kairui Tang
    Zhenping Wan
    Songmao Chen
    [J]. Journal of Solid State Electrochemistry, 2018, 22 : 825 - 833
  • [5] A nickel nanoparticle/carbon nanotube-modified carbon fiber microelectrode for sensitive insulin detection
    Lu, Longsheng
    Liang, Linsheng
    Xie, Yingxi
    Tang, Kairui
    Wan, Zhenping
    Chen, Songmao
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (03) : 825 - 833
  • [6] Fabrication and Optimization of a Molecularly Imprinted Carbon Fiber Microelectrode for Selective Detection of Met-enkephalin Using Fast-Scan Cyclic Voltammetry
    Villarini, Nicole A.
    Robins, Nathan
    Ou, Yangguang
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (23) : 29728 - 29736
  • [7] Sensitive and selective neurotransmitter epinephrine detection at a carbon quantum dots/copper oxide nanocomposite
    Elugoke, Saheed Eluwale
    Fayemi, Omolola Esther
    Adekunle, Abolanle Saheed
    Ganesh, Pattan-Siddappa
    Kim, Sang-Youn
    Ebenso, Eno E.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2023, 929
  • [8] Highly sensitive detection of hydrogen peroxide at a carbon nanotube fiber microelectrode coated with palladium nanoparticles
    Liu, Yang
    Sun, Gengzhi
    Jiang, Chunbo
    Zheng, Xin Ting
    Zheng, Lianxi
    Li, Chang Ming
    [J]. MICROCHIMICA ACTA, 2014, 181 (1-2) : 63 - 70
  • [9] Highly sensitive detection of hydrogen peroxide at a carbon nanotube fiber microelectrode coated with palladium nanoparticles
    Yang Liu
    Gengzhi Sun
    Chunbo Jiang
    Xin Ting Zheng
    Lianxi Zheng
    Chang Ming Li
    [J]. Microchimica Acta, 2014, 181 : 63 - 70
  • [10] Sensitive Electrochemical Detection of 2,4-Dichlorophenol Using Novel Carbon Fiber Microelectrode
    Yang, Zhanjun
    Huang, Xiaochun
    Li, Juan
    Ren, Yanyan
    Hu, Xiaoya
    [J]. CHEMICAL ENGINEERING AND MATERIAL PROPERTIES, PTS 1 AND 2, 2012, 391-392 : 1387 - 1391