Accuracy of retrieving optical properties from liquid tissue phantoms using a single integrating sphere

被引:5
|
作者
Vincely, Vinoin Devpaul [1 ]
Vishwanath, Karthik [1 ]
机构
[1] Miami Univ, Dept Phys, Oxford, OH 45056 USA
关键词
TURBID MEDIA; WAVELENGTH RANGE; NONINVASIVE DETERMINATION; IN-VITRO; DIFFUSE; REFLECTANCE; LIGHT; TRANSMITTANCE; SPECTROSCOPY; SYSTEM;
D O I
10.1364/AO.443854
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Using integrating spheres (ISs) in conjunction with the inverse adding-doubling algorithm (IAD) offers a well-established, rigorous protocol for determining optical absorption (mu(a)) and reduced scattering (mu(s)') coefficients of thin, optically homogeneous, turbid media. Here, we report the performance and use of a single IS system for experimentally retrieving optical properties in phantom media whose optical properties were well controlled. The IS system was used to measure the total reflectance and transmittance between 500 and 800 nm in liquid phantoms that were prepared to span a wide range of optical scattering and absorption coefficients. Measurements on phantoms were sequentially made using one of two broadband light sources-a halogen lamp or a supercontinuum laser. We report on the accuracy of IAD-derived optical coefficients using IS measurements made on phantoms-directly or by employing one of two previously reported correction methods. The first (sample-substitution error) correction was experimentally achieved while the second used Monte Carlo-based corrections with IAD. When experimentally calibrated reflectance and transmittance values were directly used as inputs to the IAD, mean absolute errors in recovered optical coefficients were larger than 0.4 cm(-1) for absorption and more than 6 cm(-1) for scattering across all phantoms and wavelengths measured. These errors reduced to 0.06-0.17 cm(-1) and 0.7-2 cm(-1) for mu(a) and mu(s)', respectively, with the use of corrections. Choice of light sources used, sample geometry (relative to optical coefficients), signal-to-noise of measurements, and the selection of correction methods are discussed. (C) 2022 Optica Publishing Group
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [1] Study of the optical properties of solid tissue phantoms using single and double integrating sphere systems
    S. Monem
    A. Singh
    A. E. Karsten
    R. Amin
    M. A. Harith
    Applied Physics B, 2015, 121 : 265 - 274
  • [2] Study of the optical properties of solid tissue phantoms using single and double integrating sphere systems
    Monem, S.
    Singh, A.
    Karsten, A. E.
    Amin, R.
    Harith, M. A.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 121 (03): : 265 - 274
  • [4] Optical characterization of liquid phantoms in 500-1000 nm using an improved single integrating sphere system
    Sun, Xiaolin
    Sun, Zhizhong
    Zhou, Tongtong
    Hu, Dong
    Sun, Tong
    Yang, Zidong
    Zhou, Guoquan
    INFRARED PHYSICS & TECHNOLOGY, 2022, 127
  • [5] Extracting broadband optical properties from uniform optical phantoms using an integrating sphere and inverse adding-doubling
    Vincely, Vinoin
    Vishwanath, Karthik
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XI, 2018, 10486
  • [6] Optical characterization of tissue mimicking phantoms by a vertical double integrating sphere system
    Han, Yilin
    Jia, Qiumin
    Shen, Shuwei
    Liu, Guangli
    Guo, Ayuwei
    Zhou, Ximing
    Chu, Jiaru
    Zhao, Gang
    Dong, Erbao
    Allen, David W.
    Lemaillet, Paul
    Xu, Ronald
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IX, 2016, 9700
  • [7] The accuracy of a commercial spectrophotometer with single integrating sphere for measuring optical properties of turbid sample
    Zhang, Yang
    Wen, Xiang
    Xu, ZhuDi
    Zhu, Dan
    OPTICAL INTERACTIONS WITH TISSUES AND CELLS XXI, 2010, 7562
  • [8] Determination of optical coefficients of biological tissue from a single integrating-sphere
    Zhang, Lianshun
    Shi, Aijuan
    Lu, Hongguang
    JOURNAL OF MODERN OPTICS, 2012, 59 (02) : 121 - 125
  • [9] Studying the distribution of deep Raman spectroscopy signals using liquid tissue phantoms with varying optical properties
    Vardaki, Martha Z.
    Gardner, Benjamin
    Stone, Nicholas
    Matousek, Pavel
    ANALYST, 2015, 140 (15) : 5112 - 5119
  • [10] Characterization and optimization of an integrating sphere based detector for the estimation of tissue optical properties
    Moscu, Diana F.
    Hayward, Joseph E.
    Farrell, Thomas J.
    Patterson, Michael S.
    NOVEL OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS III, 2007, 6631