Monitoring hemodialysis dose with ionic dialisance in on-line hemodiafiltration

被引:0
|
作者
Maduell, F [1 ]
Puchades, MJ [1 ]
Navarro, V [1 ]
Torregrosa, E [1 ]
Rius, A [1 ]
Sánchez, JJ [1 ]
机构
[1] Hosp Gen Castellon, Serv Nefrol, Castellon de La Plana 12004, Spain
来源
NEFROLOGIA | 2005年 / 25卷 / 05期
关键词
dialysis dose; ionic dialisance; non invasive monitoring; on-line hemodiafiltration;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Until now, with the ionic dialysance measurement it has been possible to determine hemodialysis dose in each session of hemodialysis (HD) and in the conventional hemofiltration (HDF) but not in the modality of on-line HDF Recently it is possible with a new biosensor that allows to measure the dose in on-line HDF The aim of this study was to evaluate the value of this biosensor in different dialysis situations comparing the dialysis dose measured in blood in comparison with the values obtained from the sensor. We have analysed 192 hemodialysis sessions performed in 24 patients, 15 male and 9 female, mean age of 70.2 +/- 12 years, included in on-line HDF All treatments were done using 4008H (Fresenius) monitor equipped with on-line clearance monitoring (OCM), that measure, with non invasive monitoring, the effective ionic dialysance equivalent to urea clearance. Every patient received eight dialysis sessions: one with dialysate flow (Qd) 500 ml/min, two with HD and Qd 800 ml/min and five with on-line HDF Other habitual haemodialysis parameters were no changed, dialysis time 200 +/- 63 min (135-300) and blood flow 421 29 ml/min (350-450). Initial and final ionic dialysance values (K), final Kt, Kt/V measured with OCM using V of Watson, and Kt/V determined in blood pre and postdialysis concentrations of urea (Daugirdas second generation), were measured. The mean of initial K was 257 +/- 27 ml/min and the final K was 234 +/- 24 ml/min. The Kt measured with OCM was 50.6 +/- 17 L, 51.2 +/- 17 in men and 49.7 +/- 76 in women. The V (Watson) was 34.5 +/- 6 L. The Kt/V measured with the Kt of OCM and V was 7,499 +/- 0.54 and Kt/V measured in blood samples was 1,742 +/- 0.58. The correlation between both values was 0.956. The Kt was different according to dialysis modality used: in HD and Qd 500 was 44.7 +/- 15 L, in HD and Qd 800 was 50.7 +/- 7 7 and in on-line HDF (22.1 +/- 7 L of reposition volume), was 51.8 +/- 17 L. The Kt/V from blood samples also shows variation: in HD and QD 500 was 1.60 +/- 0.55, in HD and Qd 800 was 1,726 +/- 0.56 and in on-line HDF was 1,776 +/- 0.59. In this study has been observed a close correlation between the new biosensor OCM with the measures obtained from the blood samples. For this reason this sensor it is useful in all modalities of dialysis treatment, included on-line HDF The sensor was able to discriminate the efficacy of different dialysis modalities used in this study.
引用
收藏
页码:521 / 526
页数:6
相关论文
共 50 条
  • [1] IONIC DIALYSANCE AND UREA CLEARANCE IN ON-LINE HEMODIAFILTRATION
    Bourry, E.
    Churlaud, G.
    Bismut, F. H.
    Petitclerc, T.
    Venditto, M.
    Szumilak, D.
    Hacini, S.
    Deray, G.
    Mercadal, L.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (07): : 405 - 406
  • [2] On-line monitoring of hemodialysis
    Petitclerc, T
    Perrone, B
    [J]. NEPHROLOGIE, 2003, 24 (02): : 75 - 78
  • [3] On-line hemodiafiltration
    Ward, RA
    [J]. NIEREN-UND HOCHDRUCKKRANKHEITEN, 1999, 28 (01) : 18 - 24
  • [4] Cardiovascular Protective Effects of On-Line Hemodiafiltration: Comparison With Conventional Hemodialysis
    Ohtake, Takayasu
    Oka, Machiko
    Ishioka, Kunihiro
    Honda, Kenjiro
    Mochida, Yasuhiro
    Maesato, Kyoko
    Moriya, Hidekazu
    Hidaka, Sumi
    Kobayashi, Shuzo
    [J]. THERAPEUTIC APHERESIS AND DIALYSIS, 2012, 16 (02) : 181 - 188
  • [5] Vancomycin hemodialysis: Clearance differences between high-flux hemodialysis and on-line hemodiafiltration
    Rodriguez, Nestor
    Gomez, Miquel
    Rico, Naira
    Maria Campistol, Josep
    Maduell, Francisco
    [J]. ARTIFICIAL ORGANS, 2019, 43 (03) : 261 - 269
  • [6] Monitoring of Dialysis Dose in Acute Kidney Injury with the Use of Kt Determinated by Ionic Dialisance
    Diez Guillermo, Rosa
    Gustavo, Greloni
    Federico, Varela
    Soledad, Crucelegui
    Sergio, Giannasi
    Roman Eduardo, San
    Salomon, Algranati
    [J]. BLOOD PURIFICATION, 2010, 30 (03) : 227 - 228
  • [7] On-line hemodiafiltration modulates atherosclerosis signaling in peripheral lymphomonocytes of hemodialysis patients
    Simone, Simona
    Chieti, Annarita
    Pontrelli, Paola
    Rascio, Federica
    Castellano, Giuseppe
    Stallone, Giovanni
    Infante, Barbara
    Gesualdo, Loreto
    Grandaliano, Giuseppe
    Pertosa, Giovanni
    [J]. JOURNAL OF NEPHROLOGY, 2021, 34 (06) : 1989 - 1997
  • [8] The anticoagulant activity of enoxaparin sodium during on-line hemodiafiltration and conventional hemodialysis
    Sombolos, Kostas I.
    Fragia, Theodora K.
    Gionanlis, Lazaros C.
    Veneti, Panagiota E.
    Bamichas, Gerasimos I.
    Fragidis, Stelios K.
    Georgoulis, Ioannis E.
    Natse, Taisir A.
    [J]. HEMODIALYSIS INTERNATIONAL, 2009, 13 (01) : 43 - 47
  • [9] On-line hemodiafiltration modulates atherosclerosis signaling in peripheral lymphomonocytes of hemodialysis patients
    Simona Simone
    Annarita Chieti
    Paola Pontrelli
    Federica Rascio
    Giuseppe Castellano
    Giovanni Stallone
    Barbara Infante
    Loreto Gesualdo
    Giuseppe Grandaliano
    Giovanni Pertosa
    [J]. Journal of Nephrology, 2021, 34 : 1989 - 1997
  • [10] Infective spondylodiscitis in patients on high-flux hemodialysis and on-line hemodiafiltration
    Abid, Saima
    De Silva, Shamila
    Warwicker, Paul
    Farrington, Ken