Understanding diagnostic disagreement in angle closure assessment between anterior segment optical coherence tomography and gonioscopy

被引:28
|
作者
Porporato, Natalia [1 ]
Baskaran, Mani [1 ]
Tun, Tin A. [1 ]
Sultana, Rehena [2 ]
Tan, Marcus [3 ]
Quah, Joanne HuiMin [4 ]
Allen, John C. [2 ]
Perera, Shamira [1 ]
Friedman, David S. [5 ]
Cheng, Ching-yu [1 ]
Aung, Tin [1 ]
机构
[1] Singapore Eye Res Inst, Singapore Natl Eye Ctr, Singapore 169856, Singapore
[2] Duke NUS Grad Med Sch, Ctr Quantitat Med, Singapore, Singapore
[3] Natl Univ Singapore Hosp, Ophthalmol, Singapore, Singapore
[4] SingHlth Polyclin, Outram Polyclin, Singapore, Singapore
[5] Massachusetts Eye & Ear Infirm, Glaucoma, Boston, MA 02114 USA
基金
英国医学研究理事会;
关键词
angle; anterior chamber; glaucoma; imaging; POPULATION; PREVALENCE; INDEX;
D O I
10.1136/bjophthalmol-2019-314672
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims Although being a more objective tool for assessment and follow-up of angle closure, reliability studies have reported a moderate diagnostic performance for anterior segment optical coherence tomography (OCT) technologies when comparing with gonioscopy as the reference standard. We aim to determine factors associated with diagnostic disagreement in angle closure when assessed by anterior segment swept source OCT (SS-OCT, CASIA SS-1000; Tomey, Nagoya, Japan) and gonioscopy. Methods Cross-sectional study. A total of 2027 phakic subjects aged >= 50 years, with no relevant previous ophthalmic history, were consecutively recruited from a community polyclinic in Singapore. Gonioscopy and SS-OCT (128 radial scans) for the entire circumference of the angle were performed for each subject. A two-quadrant closed gonioscopic definition was used. On SS-OCT images, angle closure was defined as iridotrabecular contact (ITC) to the extent of >= 35%, >= 50% and >= 75% of the circumferential angle. Diagnostic disagreements between both methods, that is, false positives or overcalls and false negatives or undercalls were defined, respectively, as gonioscopic open/closed angles inversely assessed as closed/open by SS-OCT. Results Two hundred and seventy-two (14.7%) resulted in overcall results (false positives) when >= 50% of the angle circumference was closed using SS-OCT. These eyes had significantly wider (anterior chamber width, 11.7 vs 11.6 mm, p<0.001) and deeper (anterior chamber depth (ACD), 2.4 vs 2.2 mm, p<0.001) anterior chambers than eyes assessed by both methods as closed (true positives). Deeper ACD (OR 9.31) and lower lens vault (LV) (OR 0.04) were significantly associated with a false positive diagnosis in the multivariate analysis. Most of these cases had short (52.6%) or irregular (39%) ITC in SS-OCT images. Conclusions We found that anterior chamber dimensions, determined by ACD and LV, were factors significantly associated with diagnostic disagreement between anterior segment SS-OCT and gonioscopy in angle closure assessment.
引用
收藏
页码:795 / 799
页数:5
相关论文
共 50 条
  • [1] Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography
    Elton Lik Tong Tay
    Vernon Khet Yau Yong
    Boon Ang Lim
    Stelson Sia
    Elizabeth Poh Ying Wong
    Leonard Wei Leon Yip
    [J]. International Journal of Ophthalmology, 2015, (02) : 342 - 346
  • [2] Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography
    Tay, Elton Lik Tong
    Yong, Vernon Khet Yau
    Lim, Boon Ang
    Sia, Stelson
    Wong, Elizabeth Poh Ying
    Yip, Leonard Wei Leon
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (02) : 342 - 346
  • [3] Assessment of angle closure spectrum disease as a continuum of change using gonioscopy and anterior segment optical coherence tomography
    Phu, Jack
    Wong, Brian
    Lim, Thalia
    Kalloniatis, Michael
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2020, 40 (05) : 617 - 631
  • [4] Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle
    Sakata, Lisandro M.
    Lavanya, Raghavan
    Friedman, David S.
    Aung, Han T.
    Gao, Hong
    Kumar, Rajesh S.
    Foster, Paul J.
    Aung, Tin
    [J]. OPHTHALMOLOGY, 2008, 115 (05) : 769 - 774
  • [5] Comparing anterior segment optical coherence tomography with gonioscopy performed by glaucoma experts and general ophthalmologists in angle closure suspects
    Esporcatte, Bruno
    Bufarah, Guilherme Havir
    Yamagimori, Norton S.
    Vessani, Roberto
    Melo, Luiz Alberto, Jr.
    Allemann, Norma
    Tavares, Ivan Maynart
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [6] Anterior segment optical coherence tomography in subtypes of angle closure glaucoma
    Nouri-Mahdavi, Kouros
    [J]. JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (04): : 159 - 160
  • [7] Deconstructing the mechanisms of angle closure with anterior segment optical coherence tomography
    Liu, Lance
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (07): : 614 - 622
  • [8] Anterior segment optical coherence tomography of acute primary angle closure
    Hai Tao Zhang
    Liang Xu
    Wei Fang Cao
    Ya Xing Wang
    Jost B. Jonas
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 825 - 831
  • [9] Anterior segment optical coherence tomography of acute primary angle closure
    Zhang, Hai Tao
    Xu, Liang
    Cao, Wei Fang
    Wang, Ya Xing
    Jonas, Jost B.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) : 825 - 831
  • [10] Anterior Segment Optical Coherence Tomography as a Screening Tool for the Assessment of the Anterior Segment Angle
    Pekmezci, Melike
    Porco, Travis C.
    Lin, Shan C.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (04) : 389 - 398