Anterior and posterior ratio of corneal surface areas: A novel index for detecting early stage keratoconus

被引:14
|
作者
Itoi, Motohiro [1 ]
Kitazawa, Koji [1 ,2 ]
Yokota, Isao [3 ]
Wakimasu, Koichi [2 ]
Cho, Yuko [1 ]
Nakamura, Yo [1 ]
Hieda, Osamu [1 ]
Teramukai, Satoshi [3 ]
Kinoshita, Shigeru [4 ]
Sotozono, Chie [1 ]
机构
[1] Kyoto Prefectural Univ Med, Dept Ophthalmol, Kyoto, Japan
[2] Baptist Eye Inst, Dept Ophthalmol, Kyoto, Japan
[3] Kyoto Prefectural Univ Med, Dept Biostat, Kyoto, Japan
[4] Kyoto Prefectural Univ Med, Dept Frontier Med Sci & Technol Ophthalmol, Kyoto, Japan
来源
PLOS ONE | 2020年 / 15卷 / 04期
关键词
FORME-FRUSTE KERATOCONUS; IN-SITU KERATOMILEUSIS; ELEVATION; ECTASIA; EYES;
D O I
10.1371/journal.pone.0231074
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To evaluate the diagnostic ability of the ratio of anterior and posterior corneal surface areas (As/Ps) comparing with other keratoconus screening indices in distinguishing forme fruste keratoconus (FFKC) from normal eyes. Methods In this comparative study, 13 eyes of 13 patients with FFKC, 29 eyes of 29 patients with keratoconus (KC) and 88 eyes of 88 patients with normal subjects were involved. The As/Ps measured by the anterior segment optical coherence tomography (AS-OCT) and other indices measured by AS-OCT and rotating Scheimpflug-based corneal tomography were evaluated. The area under receiver-operating-characteristics (AU-ROC) was calculated to assess the diagnostic ability in discriminating FFKC from normal eyes. Results The As/Ps, the Belin/Ambrosio display enhanced ectasia total derivation value (BAD-D) and posterior and anterior elevation values showed the AU-ROC 0.9 or more in differentiating FFKC from normal eyes (0.980, 0.951, 0.924 and 0.903, respectively). The sensitivity and specificity were 0.92 and 0.96 for the As/Ps, 1.00 and 0.90 for BAD-D, 0.85 and 0.86 for posterior elevation value, and 0.85 and 0.96 for anterior elevation value, respectively. Conclusions Among the several indices for keratoconus screening which we evaluated, the As/Ps obtained by AS-OCT had the large AU-ROC with high sensitivity and specificity in detecting FFKC, which was comparable with BAD-D obtained by rotating Scheimpflug-based corneal tomography. The As/Ps may provide information for improving the diagnostic accuracy of KC, even in the initial stage of the disease.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Diagnostic ability of the corneal anterior and posterior surface area calculated by corneal modelling approach in early stage keratoconus patients
    Ozelbaykal, Bahadir
    Kaya, Ozan
    Kasim, Burcu
    Birkandan, Tolga
    Kocluk, Yusuf
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024,
  • [2] Correlation of Anterior and Posterior Corneal Shape in Keratoconus
    Montalban, Raul
    Alio, Jorge L.
    Javaloy, Jaime
    Pinero, David P.
    [J]. CORNEA, 2013, 32 (07) : 916 - 921
  • [3] Changes in anterior and posterior corneal curvatures in keratoconus
    Tomidokoro, A
    Oshika, T
    Amano, S
    Higaki, S
    Maeda, N
    Miyata, K
    [J]. OPHTHALMOLOGY, 2000, 107 (07) : 1328 - 1332
  • [4] Involvement of anterior and posterior corneal surface area imbalance in the pathological change of keratoconus
    Koji Kitazawa
    Motohiro Itoi
    Isao Yokota
    Koichi Wakimasu
    Yuko Cho
    Yo Nakamura
    Osamu Hieda
    Shigeru Kinoshita
    Chie Sotozono
    [J]. Scientific Reports, 8
  • [5] Characteristics of corneal astigmatism of anterior and posterior surface in healthy individuals and keratoconus patients
    Schmack, Ingo
    Shajari, Gabriel
    PourSadeghian, Miad
    Remy, Matthias
    Hengerer, Fritz
    Kohnen, Thomas
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [6] Involvement of anterior and posterior corneal surface area imbalance in the pathological change of keratoconus
    Kitazawa, Koji
    Itoi, Motohiro
    Yokota, Isao
    Wakimasu, Koichi
    Cho, Yuko
    Nakamura, Yo
    Hieda, Osamu
    Kinoshita, Shigeru
    Sotozono, Chie
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [7] Correlation of Anterior and Posterior Corneal Shape in Clinical Keratoconus
    Gonzalez, Jaime Larrea
    Ramirez-Miranda, Arturo J.
    Navas, Alejandro
    Graue-Hernandez, Enrique O.
    Jimenez-Corona, Aida
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [8] Anterior and Posterior Corneal Changes after Crosslinking for Keratoconus
    Steinberg, Johannes
    Ahmadiyar, Mariam
    Rost, Anika
    Frings, Andreas
    Filev, Filip
    Katz, Toam
    Linke, Stephan J.
    [J]. OPTOMETRY AND VISION SCIENCE, 2014, 91 (02) : 178 - 186
  • [9] Distribution of Anterior and Posterior Corneal Astigmatism in Eyes With Keratoconus
    Naderan, Mohammad
    Rajabi, Mohammad Taher
    Zarrinbakhsh, Parviz
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 167 : 79 - 87
  • [10] Anterior and posterior corneal higher-order aberrations in early diagnosis and grading of keratoconus
    Yekta, Abbasali
    Hashemi, Hassan
    Ostadimoghaddam, Hadi
    Hadizadeh, Mohsen
    Rafati, Shokoofeh
    Doostdar, Asgar
    Nabovati, Payam
    Sadoughi, Mohammad Mehdi
    Khabazkhoob, Mehdi
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (03) : 263 - 270