One-Year Visual and Refractive Outcomes following LASIK for Myopia and Myopic Astigmatism with MEL 90 versus Schwind Amaris 750S Excimer Laser: A Comparative Study

被引:3
|
作者
Brar, Sheetal [1 ]
Rathod, Dishitha P. [1 ]
Roopashree, C. R. [1 ]
Ganesh, Sri [1 ]
机构
[1] Nethradhama Super Special Eye Hosp, Bangalore, Karnataka, India
关键词
FEMTOSECOND LASER; CYCLOTORSION COMPENSATION;
D O I
10.1155/2021/9929181
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare clinical outcomes following LASIK for myopia performed with MEL 90 vs. Schwind Amaris 750S excimer laser. Methods. Data were collected retrospectively for patients who underwent Femto-LASIK, using the MEL 90 and Schwind Amaris 750S excimer laser for correction of myopia and myopic astigmatism within the range of -1.00 to -10.00 D SE from January 2013 till June 2018. Outcomes were analysed at 12 months for safety, efficacy, enhancement rate, and long-term complications. Results. A total of 328 eyes of 328 patients were analysed. One hundred and sixty-three eyes were treated with Schwind Amaris and the remaining 165 eyes with the MEL 90 laser. Twelve months postoperatively, the mean UDVA, CDVA, residual SE, and cylinder in the Amaris group were -0.10 +/- 0.09 logMAR, -0.14 +/- 0.06 logMAR, -0.21 +/- 0.22 D, -0.13 +/- 0.18 D versus -0.05 +/- 0.07 logMAR, -0.09 +/- 0.08 logMAR, -0.23 +/- 0.23 D, and -0.14 +/- 0.21 D for the MEL 90 group (p values >0.05). For the Amaris group, safety and efficacy indices were 1.12 and 1.02, whereas for the MEL 90 group, these indices were 1.08 and 1.00, respectively. No eye in either group had any postop flap-related complications, infectious keratitis, diffuse lamellar keratitis, or keratectasia. Two eyes in the Amaris and 4 eyes in MEL 90 group required enhancement for the progression of myopia. Conclusion. At 12 months, both Schwind Amaris 750S and MEL 90 lasers demonstrated comparable clinical outcomes for myopic LASIK in a single surgeon setting.
引用
收藏
页数:10
相关论文
共 3 条
  • [1] Long-term assessment of visual and refractive outcomes of laser in situ keratomileusis for hyperopia using the AMARIS® 750S Excimer laser
    Demir, G.
    Sucu, M. E.
    Yildirim, Y.
    Tulu, B.
    Ozveren, M.
    Yildiz, B. Kepez
    Yasa, D.
    Gunaydin, Z. Karaagac
    Demirok, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (07): : 703 - 710
  • [2] Short-Term Visual and Refractive Outcomes of Single-Step Transepithelial Photorefractive Keratectomy with Amaris 750S and SmartSurfACE in Myopia and Astigmatism: A 6-Month Follow-Up Study
    Margarit, Daiana-Andreea
    Stanca, Horia Tudor
    Mocanu, Valeria
    Munteanu, Mihnea
    Marius, Suta
    Gheorghita, Suta
    LIFE-BASEL, 2024, 14 (10):
  • [3] Comparative analysis of visual outcomes and ocular aberrations following wavefront optimized and topography-guided customized femtosecond laser in situ keratomileusis for myopia and myopic astigmatism: A contralateral eye study
    Tiwari, Nitin N.
    Sachdev, Gitansha S.
    Ramamurthy, Shreyas
    Dandapani, Ramamurthy
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (11) : 1558 - 1561