A study of dual polymer conditioning of aluminum-based drinking water treatment residual

被引:27
|
作者
Ma, W.
Zhao, Y. Q.
Kearney, P.
机构
[1] Univ Coll Dublin, Ctr Water Resources Res, Sch Architecture Landscape & Civil Engn, Dublin 2, Ireland
[2] Dalian Univ Technol, Dept Chem, Sch Chem Engn, Dalian 116023, Peoples R China
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2007年 / 42卷 / 07期
关键词
alum sludge; capillary suction time (CST); conditioning; dewaterability; polymer; specific resistance to filtration (SRF);
D O I
10.1080/10934520701370261
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Conditioning of an aluminum-based water treatment sludge by single and dual polymers was investigated in this study. Capillary suction time (CST), specific resistance to filtration (SRF) and settling rate were used to evaluate the sludge dewatering characteristics. Sludge dewaterability resulting from single and dual polymer conditioning were compared for the purpose of exploring the validity and effectiveness of dual polymer conditioning strategy. Unlike activated sludge derived from wastewater treatment, results from this study have demonstrated that conditioning of the alum sludge by the combined use of an cationic polymer (FO-4140) followed by an anionic polymer (LT-25) does not exhibit considerable advantage in further improvement of sludge dewaterability with comparison of single polymer conditioning. This study supports the view that for aluminum-based water treatment sludge, inter particle bridging seems to be the dominative mechanism and the charge neutralization plays a less important role in the conditioning process. In addition, an intrinsic relationship between CST and SRF was deducted and tested via the experimental data obtained from the study.
引用
收藏
页码:961 / 968
页数:8
相关论文
共 50 条
  • [1] Aging effects on reactivity of an aluminum-based drinking-water treatment residual as a soil amendment
    Agyin-Birikorang, S.
    O'Connor, G. A.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2009, 407 (02) : 826 - 834
  • [2] Study on adsorption of phosphorus by modified aluminum-based drinking water treatment sludge
    Qin, Zhenhua
    Yu, Jiuhong
    Chen, Ken
    Fan, Guozhi
    Cheng, Qunpeng
    Song, Guangsen
    DESALINATION AND WATER TREATMENT, 2019, 153 : 76 - 84
  • [3] Impacts of substituting aluminum-based coagulants in drinking water treatment
    Niquette, P
    Monette, F
    Azzouz, A
    Hausler, R
    WATER QUALITY RESEARCH JOURNAL OF CANADA, 2004, 39 (03): : 303 - 310
  • [4] The diversity of aluminum-based drinking water treatment residuals for use in environmental remediation
    Wallace, Samuel M. M.
    Zhang, Yuchi
    Zhou, Lang
    Ma, Qing
    Guise, William E. E.
    Denslow, Nancy D. D.
    Bonzongo, Jean-Claude
    Gaillard, Jean-Francois
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2023, 9 (03) : 935 - 947
  • [5] Ferrocyanide removal from solution by aluminum-based drinking water treatment residue
    Liu, Xin
    Liu, Rui
    Yuan, Nannan
    Zhao, Yuanyuan
    Wang, Changhui
    Wan, Xinyue
    Shang, Yubo
    CHEMOSPHERE, 2020, 247
  • [6] A method for determining the phosphorus sorption capacity and amorphous aluminum of aluminum-based drinking water treatment residuals
    Dayton, EA
    Basta, NT
    JOURNAL OF ENVIRONMENTAL QUALITY, 2005, 34 (03) : 1112 - 1118
  • [7] Aluminum-based drinking-water treatment residuals: A novel sorbent for perchlorate removal
    Makris, KC
    Sarkar, D
    Datta, R
    ENVIRONMENTAL POLLUTION, 2006, 140 (01) : 9 - 12
  • [8] Aluminum-Based Water Treatment Residual Use in a Constructed Wetland for Capturing Urban Runoff Phosphorus: Column Study
    J. A. Ippolito
    Water, Air, & Soil Pollution, 2015, 226
  • [9] Aluminum-Based Water Treatment Residual Use in a Constructed Wetland for Capturing Urban Runoff Phosphorus: Column Study
    Ippolito, J. A.
    WATER AIR AND SOIL POLLUTION, 2015, 226 (10):
  • [10] Dual polymer conditioning of water treatment residuals
    Ayol, A
    Dentel, SK
    Filibeli, A
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2005, 131 (08) : 1132 - 1138