The noninvasive and optical only glucose monitoring investigation and analysis

被引:0
|
作者
Lee, Yi-Hsiung [1 ]
Lin, Yu-Hsuan [1 ]
Tsai, Hsin-Yi [1 ]
Hsiao, Wen-Tse [1 ]
Huang, Kuo-Cheng [1 ]
机构
[1] Natl Appl Res Labs, Taiwan Instrument Res Inst, Hsinchu, Taiwan
关键词
optical path lengths; laser diode powers; precipitation times of glucose; noninvasive optical only glucose monitoring;
D O I
10.1109/I2MTC50364.2021.9459869
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For preventive medicine, regular glucose monitoring is the potential production to detect the possibility of diseases at an early stage. The noninvasive and optical only glucose sensor is more user-friendly for customers because of the advantages of small size, low cost, and easy operation. The near-infrared (NIR) glucose sensor is the most popular analytic method based on the glucose properties of overtones and combinational bands. For hardware setup, the 3D printing machine was used to fabricate the assembly components including the sample cuvette structure, the sample holder, and the laser diode stage, etc. The sample cuvette was composed of the structure with two square glasses with optical path length of 1, 1.5, 2 mm, and the optical component include the 1456 nm laser diode and the PD (photodiode). This paper investigates the glucose precipitation experiment (0-90 min), the response voltages with the different optical path lengths (1, 1.5, and 2 mm), and the response voltages with the laser power was 574, 798, 950, and 1045 mW/cm(2) according to Beer-Lambert law, respectively. In the results, the different response voltages had not different when the precipitation time less than 90 min. In addition, the concentration of the glucose solution with the same optical path length and the same laser power was proportional to the response voltage. The optical path length with the same concentration of the glucose solution and the same laser power was inversely proportional to the response voltage. The laser power with the same optical path length and the same concentration of the glucose solution was proportional to the response voltage. The 1 mm optical path length and the 1045 mW/cm(2) laser power had the best discrimination than the other optical path lengths and the other laser powers. The experiment results indicate that the shortest optical path length and the largest laser power are required for the best discrimination of the noninvasive and optical only glucose monitoring production.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Investigation of pH and temperature on optical rotatory dispersion for noninvasive glucose monitoring
    Baba, JS
    Meledeo, A
    Cameron, BD
    Coté, GL
    [J]. OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING, 2001, 4263 : 25 - 33
  • [2] Optical Methods for Noninvasive Blood Glucose Monitoring
    N. A. Bazaev
    Yu. P. Masloboev
    S. V. Selishchev
    [J]. Biomedical Engineering, 2012, 45 (6) : 229 - 233
  • [3] Optical Based Noninvasive Glucose Monitoring Sensor Prototype
    Haxha, Shyqyri
    Jhoja, Jaspreet
    [J]. IEEE PHOTONICS JOURNAL, 2016, 8 (06):
  • [4] Noninvasive glucose monitoring in vivo with an optical heterodyne polarimeter
    Division of Radiology, Sch. of Med. Technol. and Eng., National Yang Ming University, Shi-pai, Taipei 112, Taiwan
    不详
    不详
    [J]. Appl. Opt., 16 (3553-3557):
  • [5] Noninvasive glucose monitoring in vivo with an optical heterodyne polarimeter
    Chou, C
    Han, CY
    Kuo, WC
    Huang, YC
    Feng, CM
    Shyu, JC
    [J]. APPLIED OPTICS, 1998, 37 (16): : 3553 - 3557
  • [6] Noninvasive monitoring of glucose concentration with optical coherence tomography
    Esenaliev, RO
    Larin, KV
    Larina, IV
    Motamedi, M
    [J]. OPTICS LETTERS, 2001, 26 (13) : 992 - 994
  • [8] Noninvasive glucose monitoring
    Thomas, A.
    Heinemann, L.
    [J]. DIABETOLOGE, 2014, 10 (01): : 36 - 42
  • [9] Investigation of Resonant Frequency and Impedance for Noninvasive Blood Glucose Monitoring
    Li, Jingzhen
    Yang, Dardei
    Nie, Zedong
    Liu, Yuhang
    Wang, Lei
    [J]. 2017 IEEE 7TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2017, : 1649 - 1652
  • [10] Specificity of noninvasive blood glucose monitoring with optical coherence tomography
    Larin, KV
    Ashitkov, TV
    Motamedi, M
    Esenaliev, RO
    [J]. OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 25 - 31