Setup Management for Stereotactic Body Radiation Therapy of Patients With Pancreatic Cancer Treated via the Breath-Hold Technique

被引:8
|
作者
Teboh, Roland Forbang [1 ,2 ]
Srinivasan, Senthamizhchelvan [1 ,3 ]
Ng, Sweet Ping [4 ]
Aliru, Maureen L. [4 ]
Herman, Joseph M. [1 ,4 ]
机构
[1] Johns Hopkins Univ, Sch Med, Baltimore, MD 21205 USA
[2] Hackensack Univ, John Theurer Canc Ctr, Med Ctr, Hackensack, NJ 07601 USA
[3] Mem Hlth Care Syst, Chattanooga, TN USA
[4] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
BEAM COMPUTED-TOMOGRAPHY; LUNG-TUMOR POSITION; CONTROL ABC; SHORT-TERM; REPRODUCIBILITY; RADIOTHERAPY; COORDINATOR; TRACKING; EUS;
D O I
10.1016/j.prro.2019.10.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Active Breathing Coordinator (Elekta AB, Crawley, UK) is a motion management strategy for radiation treatment. During setup, aligning the patient to the bony spine alone does not necessarily lead to an accurate alignment to soft tissue targets, and further adjustment is necessary. Determining a safe range of values for such adjustments is an important quality assurance measure and was the purpose of this study, with focus on stereotactic body radiation therapy in patients with pancreatic cancer. Methods and Materials: The retrospective study included 19 previously treated patients. For each fraction, a free-breathing cone beam computed tomography scan was registered to a reference breath-hold computed tomography for alignment to the spine. Two perpendicular breath-hold kV projection images were then acquired and compared with corresponding reference digitally reconstructed radiographs for additional alignment with a surrogate fiducial marker. By comparing the breath-hold kV projection images from subsequent treatment fractions with those from the first fraction, we derived the 3-dimensional variability of the fiducial position with respect to the reference image. Results: We observed intrafraction setup error to be within 2.0 mm. For interfraction, we observed average reproducibility of 1.7 +/- 0.8 mm, 2 0 +/- 1.4 mm, and 3.2 +/- 2.5 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. The average excursion values from free breathing spine to breath-hold fiducial alignment were 1.5 +/- 1.4 mm, 2.0 +/- 1.9 mm, and 3.0 +/- 2.0 mm in the LR, AP and SI directions, respectively. The observed ranges of average excursions among all patients were 0.2 to 5.1 mm, 0.1 to 5. 9 mm, and 0.6 to 7.8 mm in the LR, AP, and SI directions, respectively. Conclusions: This study demonstrates that intrafraction targeting errors can be within 2 mm, and interfraction shifts from free-breathing spine to Active Breathing Coordinator breath-hold target can be as high as 8 mm. Values that deviate significantly would need further investigation to rule out factors such as local progression, bowel gas, or fiducial shift before treatment. (C) 2019 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E280 / E289
页数:10
相关论文
共 50 条
  • [1] Verification of Breath-Hold Technique in Stereotactic Body Radiation Therapy for Lung Cancer: What Are the Optimal Margins?
    Okazaki, D.
    Murai, T.
    Nakajima, K.
    Kondo, T.
    Yanagi, T.
    Fukuma, H.
    Eguchi, Y.
    Kitagawa, H.
    Tuchiya, T.
    Hirose, Y.
    Shibamoto, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E706 - E707
  • [2] Patient Setup Management for Pancreatic Stereotactic Body Radiation Therapy: Interfraction Adjustment Between Spine Alignment and the Pancreatic Fiducial During Breath-Hold kV Imaging
    Forbang, R. Teboh
    Srinivasan, S.
    Ellsworth, S.
    Shin, E.
    Khashab, M.
    O'Broin-Lennon, A.
    Pawlik, T.
    Wolfgang, C.
    Laheru, D.
    Herman, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S364 - S364
  • [3] Breath-hold cone-beam CT for patient setup in stereotactic body radiation therapy for lung tumors
    Duggan, D.
    Ding, G.
    Coffey, C.
    Lu, B.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2027 - 2027
  • [4] Split-VMAT technique to control the expiratory breath-hold time in liver stereotactic body radiation therapy
    Lin, Yen Hwa
    Ozawa, Shuichi
    Miura, Hideharu
    Yogo, Katsunori
    Nakashima, Takeo
    Miki, Kentaro
    Tsuda, Shintaro
    Ochi, Yusuke
    Kawahara, Daisuke
    Kimura, Tomoki
    Saito, Akito
    Nagata, Yasushi
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 40 : 17 - 23
  • [5] Impact of Deep Inspiration Breath-Hold Parameters and Gastrointestinal Gas Volume on Tumor Position Uncertainty in Stereotactic Body Radiation for Pancreatic Cancer
    Han-Oh, S.
    Hsu, L.
    Hill, C.
    Lin, H.
    Martin-Gomez, A.
    Narang, A.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Deep-inspiration breath-hold kilovoltage cone-beam CT for setup of stereotactic body radiation therapy for lung tumors: Initial experience
    Duggan, Dennis M.
    Ding, George X.
    Coffey, Charles W., II
    Kirby, Wyndee
    Hallahan, Dennis E.
    Malcolm, Arnold
    Lu, Bo
    [J]. LUNG CANCER, 2007, 56 (01) : 77 - 88
  • [7] Patterns of Regional Failure in Patients with Pancreatic Cancer treated with Stereotactic Body Radiation Therapy
    Baclay, J. R. M.
    Toesca, D. A. S.
    Von Eyben, R.
    Pollom, E.
    Chang, D. T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E584 - E585
  • [8] Surgical outcomes of patients with pancreatic cancer treated with stereotactic body radiation therapy.
    He, Jin
    Moningi, Shalini
    Blair, Alex B.
    Zaki, Ahmed
    Laheru, Daniel A.
    Cameron, John L.
    Pawlik, Timothy M.
    Weiss, Matthew J.
    Wolfgang, Christopher Lee
    Herman, Joseph M.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (03)
  • [9] Deep-Inspiration Breath-Hold Stereotactic Body Radiation Therapy by Combining Spirometer-Guided Breath-Hold and a Real-Time Tumor Tracking System: A Novel Approach
    Tanaka, H.
    Ueda, K.
    Karita, M.
    Ono, T.
    Kajima, M.
    Manabe, Y.
    Sera, T.
    Fujimoto, K.
    Yuasa, Y.
    Shiinoki, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E63 - E64
  • [10] Feasibility of a feedback-guided breath-hold technique for thoracic radiation therapy
    Kainz, K.
    Liu, H.
    Balter, P.
    Tutt, T.
    Hunjan, S.
    Prado, K.
    Liao, Z.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2035 - 2035