Fuzzy logic based estimation of effective lengths of columns in partially braced multi-storey frames

被引:1
|
作者
Menon, D [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Madras 600036, Tamil Nadu, India
关键词
effective length; K-factor; column; multi-storey frame; partial bracing; stability index; fuzzy logic; membership function; degree of bracing;
D O I
10.12989/sem.2001.11.3.287
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Columns in multi-storey frames are presently categorised as either braced or unbraced, usually by means of the stability index criterion, for estimating their effective length ratios by design aids such as 'alignment charts'. This procedure, however, ignores the transition in buckling behaviour between the braced condition and the unbraced one. Hence, this results in either an overestimation or an underestimation of effective length estimates of columns in frames that are in fact 'partially braced'. It is shown in this paper that the transitional behaviour is gradual, and can be approximately modelled by means of a 'fuzzy logic' based technique. The proposed technique is simple and intuitively agreeable. It fills the existing gap between the braced and unbraced conditions in present codal provisions.
引用
收藏
页码:287 / 299
页数:13
相关论文
共 38 条
  • [1] Effective Lengths of Columns in Braced Multi-Storey Frames
    Girgin, Konuralp
    Ozmen, Guenay
    TEKNIK DERGI, 2008, 19 (01): : 4333 - 4346
  • [2] Effective lengths of columns in braced multi-storey frames
    Istanbul Technical University, Istanbul, Turkey
    不详
    Teknik Dergi/Technical Journal of Turkish Chamber of Civil Engineers, 2008, 19 (SPEC. ISS.): : 1203 - 1216
  • [3] The effective length of columns in multi-storey frames
    Webber, A.
    Orr, J. J.
    Shepherd, P.
    Crothers, K.
    ENGINEERING STRUCTURES, 2015, 102 : 132 - 143
  • [4] Flexural demand on partially-encased composite columns in multi-storey concentrically braced steel frames
    Tremblay, R
    Tirca, L
    Bouchereau, R
    Toupin, JD
    Massicotte, B
    STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2003, : 479 - 485
  • [5] Performance based design approach for multi-storey concentrically braced steel frames
    Salawdeh, Suhaib
    Goggins, Jamie
    STEEL AND COMPOSITE STRUCTURES, 2016, 20 (04): : 749 - 776
  • [6] Buckling lengths of unbraced multi-storey frame columns
    Özmen, G
    Girgin, K
    STRUCTURAL ENGINEERING AND MECHANICS, 2005, 19 (01) : 55 - 71
  • [7] Incremental dynamic analysis of multi-storey concentrically braced steel frames
    Tirca, L.
    Tremblay, R.
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 359 - 366
  • [8] Storey-based stability analysis of multi-storey unbraced frames
    Liu, Y
    Xu, L
    STRUCTURAL ENGINEERING AND MECHANICS, 2005, 19 (06) : 679 - 705
  • [9] Performance-based seismic design and assessment of multi-storey CFS strap-braced frames
    Papargyriou, Ioannis
    Hajirasouliha, Iman
    ENGINEERING STRUCTURES, 2022, 261
  • [10] Behaviour and design of multi-storey zipper concentrically braced steel frames for the mitigation of soft-storey response
    Tremblay, R
    Tirca, L
    STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2003, : 471 - 477