Standardization of tritium measuring devices based on a high-sensitivity calorimeter

被引:4
|
作者
Matsuyama, Masao [1 ]
Hara, Masanori [1 ]
机构
[1] Toyama Univ, Hydrogen Isotope Res Ctr, Toyama 9308555, Japan
关键词
D O I
10.13182/FST08-A1791
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A twin type thermal conduction calorimeter has been specially designed and constructed for absolute measurement of tritium, and then its performance was examined using two kinds of tritium samples, i.e., ZrNi alloy powders loaded with a given amount of tritium. Total amounts of tritium in the ZrNi alloy powders were previously estimated by a small ionization chamber Changes in radioactivity of two samples werefollowedfor three years, and it was seen that the activity changes obeys the half-life of 4505 days. The initial tritium amounts estimated by the small ionization chamber agreed well with the extrapolated values from the activity changes evaluated by the calorimeter Namely, it was suggested that the small ionization chamber is able to be used as a secondary standard of the tritium measuring devices. The beta-ray-induced X-ray counter was also calibrated for non-destructive measurements of high-level tritium by using the present small ionization chamber.
引用
收藏
页码:182 / 185
页数:4
相关论文
共 50 条
  • [1] CREATION OF HIGH-SENSITIVITY CONDUCTION CALORIMETER
    REGGIANI, JC
    BERNARD, J
    CUDEY, G
    REVUE GENERALE DE THERMIQUE, 1972, 11 (126): : 581 - &
  • [2] HIGH-RESOLUTION, HIGH-SENSITIVITY AC CALORIMETER
    BEDNARZ, G
    MILLIER, B
    WHITE, MA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08): : 3944 - 3952
  • [3] A SIMPLE HEAT CONDUCTING CALORIMETER WITH HIGH-SENSITIVITY
    KUZEL, HJ
    FORTSCHRITTE DER MINERALOGIE, 1982, 60 : 128 - 129
  • [4] A HIGH-SENSITIVITY TITRATION CALORIMETER USING PYROELECTRIC SENSOR
    MERABET, EK
    YUEN, HK
    GROTE, WA
    DEPPERMANN, KL
    JOURNAL OF THERMAL ANALYSIS, 1994, 42 (05): : 895 - 906
  • [5] HIGH-SENSITIVITY CALORIMETER FOR MEASUREMENT OF SMALL HEAT CHANGES
    YUREVICH, LV
    SOLDATOV, V
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY,USSR, 1972, 46 (01): : 160 - &
  • [6] DEVELOPMENT OF A HIGH-SENSITIVITY, COMPUTER-CONTROLLED TITRATION CALORIMETER
    BAISDEN, PA
    GRANT, PM
    KINARD, WF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (10): : 1937 - 1941
  • [7] MEASURING AMBIENT OZONE WITH HIGH-SENSITIVITY AND BANDWIDTH
    PEARSON, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (02): : 907 - 916
  • [8] High-sensitivity gas pressure sensors based on in-fiber devices
    Wang, Yiping
    Liao, Changrui
    Liu, Shen
    Sun, Bing
    Li, Zhengyong
    Zhong, Xiaoyong
    Yin, Guolu
    FIFTH ASIA-PACIFIC OPTICAL SENSORS CONFERENCE, 2015, 9655
  • [9] A high-sensitivity differential scanning calorimeter with magnetic field for magnetostructural transitions
    Marcos, J
    Casanova, F
    Batlle, X
    Labarta, A
    Planes, A
    Mañosa, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (11): : 4768 - 4771
  • [10] A HIGH-SENSITIVITY MICROFLUIDIC CHIP CALORIMETER FOR BIOCHEMICAL REACTION MONITORING APPLICATIONS
    Huang, Jianze
    Zhang, Congchun
    Ding, Guifu
    Yang, Zhuoqing
    Zhao, Xiaolin
    Liu, Yang
    Tang, Zhiyong
    Shao, Xiufeng
    Yang, Shenyong
    Lin, Xingkai
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 1140 - 1143