Seismic response mitigation of buildings with an active inerter damper system

被引:12
|
作者
Chen, Pei-Ching [1 ]
Chen, Po-Chang [1 ]
Ting, Guan-Chung [2 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Taipei, Taiwan
[2] Natl Taiwan Univ, Taipei, Taiwan
来源
关键词
active inerter damper; force tracking; seismic response mitigation; shake table test; structural control; VIBRATION CONTROL; MASS DAMPER; FEEDBACK; LQR;
D O I
10.1002/stc.2975
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is realized that force exerted at the two ends of an inerter is proportional to their relative acceleration between them. Generally, a mechanical inerter has much smaller mass than a conventional mass damper when identical inertial force is attained due to its mechanical characteristics. In this study, a novel active control system named active inerter damper (AID) is proposed to mitigate seismic response of buildings which is composed of a mechanical ball-screw inerter, a servo-hydraulic actuator, sensors, and a digital controller. Compared to an active mass damper, the AID requires less mass support structure and installation space in real engineering practice. In this paper, two force tracking controllers for the AID system are proposed, designed, and validated in the laboratory first which aim to impose control force on buildings accurately because force tracking performance of an active control system is extremely crucial to its seismic control performance. Afterwards, shake table tests of a three-story steel specimen with an AID system are conducted to validate the feasibility of AID control application for buildings. The control force is computed from a machine learning-based controller that utilizes acceleration feedback directly from the steel specimen. Experimental results demonstrate that force tracking performance of the AID system is satisfactory. Meanwhile, the AID system mitigates seismic response of the steel specimen successfully and effectively.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] A novel nonlinear isolated rooftop tuned mass damper-inerter (IR-TMDI) system for seismic response mitigation of buildings
    Komal Rajana
    Agathoklis Giaralis
    [J]. Acta Mechanica, 2023, 234 : 3751 - 3777
  • [2] A novel nonlinear isolated rooftop tuned mass damper-inerter (IR-TMDI) system for seismic response mitigation of buildings
    Rajana, Komal
    Giaralis, Agathoklis
    [J]. ACTA MECHANICA, 2023, 234 (09) : 3751 - 3777
  • [3] A particle inerter system for structural seismic response mitigation
    Zhao, Zhipeng
    Zhang, Ruifu
    Lu, Zheng
    [J]. JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2019, 356 (14): : 7669 - 7688
  • [4] The Seismic Mitigation Design of Tuned Inerter Damper for Building Structure
    Liu L.
    Tan P.
    Yan W.
    Zhou F.
    [J]. Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2018, 38 (04): : 751 - 757
  • [5] Seismic response mitigation of structures with a friction pendulum inerter system
    Zhao, Zhipeng
    Zhang, Ruifu
    Jiang, Yiyao
    Pan, Chao
    [J]. ENGINEERING STRUCTURES, 2019, 193 : 110 - 120
  • [6] Active nonlinear inerter damper for vibration mitigation of Duffing oscillators
    Zhao, G.
    Raze, G.
    Paknejad, A.
    Deraemaeker, A.
    Kerschen, G.
    Collette, C.
    [J]. JOURNAL OF SOUND AND VIBRATION, 2020, 473
  • [7] Seismic response control of adjacent buildings using optimal backward-shared tuned mass damper inerter and optimal backward-shared tuned inerter damper
    Djerouni S.
    Abdeddaim M.
    Ounis A.
    [J]. Asian Journal of Civil Engineering, 2021, 22 (8) : 1499 - 1523
  • [8] Dual-Demand-Based Optimal Design of Grounded Tuned Mass Damper Inerter for Seismic Response Mitigation
    Zhang, Ruoyu
    Huang, Jizhong
    Zhang, Yue
    [J]. JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2024, 12 (02) : 1429 - 1443
  • [9] Dual-Demand-Based Optimal Design of Grounded Tuned Mass Damper Inerter for Seismic Response Mitigation
    Ruoyu Zhang
    Jizhong Huang
    Yue Zhang
    [J]. Journal of Vibration Engineering & Technologies, 2024, 12 : 1429 - 1443
  • [10] Tandem tuned mass damper inerter for passive control of buildings under seismic loads
    Farzam, Maziar Fahimi
    Jalali, Himan Hojat
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (09):