Study of indoor radon levels in Garhwal Himalayas using solid state nuclear track detector

被引:0
|
作者
Ramola, RC [1 ]
机构
[1] Dept Phys, Tehri Garhwal 249001, India
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The measurements of radon in indoor and outdoor environment by using LR-115 type II, plastic track detector in bare mode have been carried out in four districts (Tehri, Pauri, Utterkashi and Dehradun) of Garhwal Himalaya. One year data has been obtained from each house which is distributed in four quarters viz. Winter, Summer, Rainy and Autumn. About 350 houses have been surveyed and the radon levels were found to vary from 25 to 395 Bq/m(3). The annual average radon values were found to vary from 59 Bq/m(3) to 303 Bq/m(3). The indoor radon concentration was found to vary with seasonal variation, building material and mode of the construction of house. The winter/summer ratios for different type of houses vary substantially among different places. The radon concentration was found higher in mud houses due to the typical houses construction and building material used. More that 50% values of radon concentrations in mud houses are recorded above the ICRP recommended values and there is a specific need to measure the effect to the people living there. The results show that the building materials, mode of construction of house and the seasonal variations should be taken in account to calculate annual effective dose equivalent.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 50 条
  • [1] CALIBRATION OF A SOLID-STATE NUCLEAR TRACK DETECTOR FOR THE MEASUREMENT OF INDOOR LEVELS OF RADON AND ITS DAUGHTERS
    RAMU, MCS
    MURALEEDHARAN, TS
    RAMACHANDRAN, TV
    SCIENCE OF THE TOTAL ENVIRONMENT, 1988, 73 (03) : 245 - 255
  • [2] Measurement of indoor radon levels in Erbil capital by using solid state nuclear track detectors
    Mansour, HH
    Khdar, SP
    Abdulla, HY
    Muhamad, NQ
    Othman, MM
    Qader, S
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 544 - 547
  • [3] Measurement of Radon exhalation rate using Solid State Nuclear Track Detector
    Singh, Lalit Mohan
    Singh, K. Y.
    Mahur, Ajay
    Kumar, Dinesh
    Gupta, Devesh
    ADVANCES IN BASIC SCIENCES (ICABS 2019), 2019, 2142
  • [4] Estimation of indoor radon levels using etched track detector
    El-Badry, Basma A.
    Al-Naggar, Tayseer, I
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2018, 11 (04) : 355 - 360
  • [5] A STUDY OF INDOOR RADON LEVELS IN RURAL DWELLINGS OF EZINE (CANAKKALE, TURKEY) USING SOLID-STATE NUCLEAR TRACK DETECTORS
    Orgun, Y.
    Altinsoy, N.
    Sahin, S. Y.
    Ataksor, B.
    Celebi, N.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (03) : 379 - 384
  • [6] Assessment of Indoor Radon Levels in Some Parts of North India, Using Solid State Nuclear Track Detectors
    Shikha, Deep
    Singh, Tejinder Pal
    Pal, Mohinder
    ADVANCES IN BASIC SCIENCES (ICABS 2019), 2019, 2142
  • [7] Modelling of solid state nuclear track detector devices for radon measurements
    Andriamanatena, R
    Bacmeister, GU
    Freyer, K
    Ghose, R
    Jonsson, G
    Kleis, T
    Treutler, HC
    Enge, W
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 657 - 662
  • [8] INDOOR RADON MEASUREMENT METHODOLOGY BY SOLID-STATE NUCLEAR TRACK DETECTORS
    ESPINOSA, G
    RAMOS, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 161 (02): : 307 - 312
  • [9] The calibration of the solid state nuclear track detector LR 115 for radon measurements
    Gericke, C
    Ghose, R
    Jönsson, G
    Freyer, K
    Treutler, HC
    Enge, W
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 363 - 366
  • [10] Automating radon solid state track detector measurements
    Fairchild, Robert
    Tjong, Lydiawati
    Wright, Tracy