Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantom

被引:138
|
作者
Siantar, CLH [1 ]
Walling, RS
Daly, TP
Faddegon, B
Albright, N
Bergstrom, P
Chuang, C
Garrett, D
House, RK
Knapp, D
Wieczorek, DJ
Verhey, LJ
机构
[1] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[3] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Monte Carlo; radiation therapy; treatment planning; dose calculation;
D O I
10.1118/1.1381551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PEREGRINE is a three-dimensional Monte Carlo dose calculation system written specifically for radiotherapy. This paper describes the implementation and overall dosimetric accuracy of PEREGRINE physics algorithms, beam model, and beam commissioning procedure. Particle-interaction data, tracking geometries, scoring, variance reduction, and statistical analysis are described. The BEAM code system is used to model the treatment-independent accelerator head, resulting in the identification of primary and scattered photon sources and an electron contaminant source. The magnitude of the electron source is increased to improve agreement with measurements in the buildup region in the largest fields. Published measurements provide an estimate of backscatter on monitor chamber response. Commissioning consists of selecting the electron beam energy, determining the scale factor that defines dose per monitor unit, and describing treatment-dependent beam modifiers. We compare calculations with measurements in a water phantom for open fields, wedges, blocks, and a multileaf collimator for 6 and 18 MV Varian Clinac 2100C photon beams. All calculations are reported as dose per monitor unit. Aside from backscatter estimates, no additional, field-specific normalization is included in comparisons with measurements. Maximum discrepancies were less than either 2% of the maximum dose or 1.2 mm in isodose position for all field sizes and beam modifiers. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1322 / 1337
页数:16
相关论文
共 50 条
  • [1] Photon beam description in PEREGRINE for Monte Carlo dose calculations
    Cox, LJ
    vonWittenau, AES
    Bergstrom, PM
    Mohan, R
    Libby, B
    Wu, Q
    Lovelock, DMJ
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 142 - 145
  • [2] Clinical implementation of the PEREGRINE Monte Carlo dose calculation system for photon-beam therapy
    Siantar, CLH
    Bergstrom, PM
    Daly, TP
    Descalle, MA
    Garrett, D
    House, RK
    Knapp, DK
    May, S
    Patterson, RW
    Walling, RS
    Albright, N
    Verhey, L
    Weiczorek, D
    [J]. RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 199 - 203
  • [3] Application of the peregrine Monte Carlo dose calculation system to stereotactic radiosurgery
    Siantar, CLH
    Cox, LJ
    vonWittenau, AS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 182 - 182
  • [4] Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation
    Yang, J
    Li, JS
    Qin, L
    Xiong, W
    Ma, CM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2657 - 2673
  • [5] Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams
    Kuenzler, Thomas
    Fotina, Irina
    Stock, Markus
    Georg, Dietmar
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24): : 7363 - 7377
  • [6] Monte carlo dose calculation in dental amalgam phantom
    Aziz, Mohd. Zahri Abdul
    Yusoff, A. L.
    Osman, N. D.
    Abdullah, R.
    Rabaie, N. A.
    Salikin, M. S.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (03) : 150 - 155
  • [7] Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    Fippel, M
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1466 - 1475
  • [8] A patient-specific Monte Carlo dose-calculation method for photon beams
    Wang, L
    Chui, CS
    Lovelock, M
    [J]. MEDICAL PHYSICS, 1998, 25 (06) : 867 - 878
  • [9] Development of a Monte Carlo-Based Dose-Calculation System in a Cloud Environment for IMRT and VMAT Dosimetric Verification
    Fujita, Y.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3391 - 3391
  • [10] Macro Monte Carlo for dose calculation of proton beams
    Fix, Michael K.
    Frei, Daniel
    Volken, Werner
    Born, Ernst J.
    Aebersold, Daniel M.
    Manser, Peter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2027 - 2044