A Simple Harmonic Reduction Method in 20-Pulse AC-DC Converter

被引:16
|
作者
Abdollahi, Rohollah [1 ]
机构
[1] Tech & Vocat Univ, Qom Boys Tech Coll, Dept Elect Engn, Qom, Iran
关键词
AC-DC converter; passive harmonic reduction; 20 pulse rectifier; direct torque controlled induction motor drive (DTCIMD); POWER QUALITY IMPROVEMENT; INDUCTION-MOTOR DRIVES; RETROFIT APPLICATIONS; MITIGATION; DESIGN;
D O I
10.1142/S0218126619500130
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a simple and passive harmonic reduction method at dc link of 20-pulse rectifier. The 20-pulse topology is obtained via two paralleled 10-pulse ac-dc converters, each of them consisting of a five-phase (five-leg) diode bridge rectifier. For independent operation of the paralleled diode-bridge rectifiers, a zero sequence blocking transformer (ZSBT) is designed and implemented. Connection of a tapped inter-phase transformer (IPT) at the output of the ZSBT results in doubling the number of the output voltage pulses. The application of the pulse doubling technique with a low power rating (2% of the load power rating) results in a simpler and more economical con figuration of the whole system and increased number of pulses. The design is suitable for retro fit applications where a six-pulse diode bridge rectifier is being utilized. The proposed structure is simulated using Matlab/Simulink software under different loading conditions. The simulation results con firm the significant improvement of the power quality indices (IEEE-519 standard requirements) at the point of common coupling (PCC). Experimental results are obtained using the designed and constructed laboratory prototype of the proposed converter to validate the design procedure and the simulation results. The VA rating of the magnetic circuit is calculated to con firm the savings in space, volume, weight and cost of the proposed configuration.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Design and Experimental Verification of 20-Pulse AC-DC Converter for Retrofit Applications and Harmonic Mitigation
    Abdollahi, Rohollah
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2017, 26 (10)
  • [2] Autoconnected-Transformer-Based 20-Pulse AC-DC Converter for Telecommunication Power Supply
    Kalpana, R.
    Bhuvaneswari, G.
    Singh, Bhim
    Singh, Shikha
    Gairola, Sanjay
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (10) : 4178 - 4190
  • [3] DEVELOPMENT OF A 20-PULSE AC-DC CONVERTER BASED IN THREE-TO-FIVE PHASES TRANSFORMER
    de Morais, Juliano Luiz dos Santos
    de Morais, Julio Cezar dos Santos
    Badin, Alceu Andre
    Gules, Roger
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [4] A 28-pulse AC-DC converter for line current harmonic reduction
    Singh, B.
    Gairola, S.
    IET POWER ELECTRONICS, 2008, 1 (02) : 287 - 295
  • [5] A 36-pulse AC-DC converter for line current harmonic reduction
    Singh, Bhim
    Gairola, Sanjay
    2006 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONIC, DRIVES AND ENERGY SYSTEMS, VOLS 1 AND 2, 2006, : 701 - +
  • [6] Hexagon-Connected Transformer-Based 20-Pulse AC-DC Converter for Power Quality Improvement
    Abdollahil, Rohollah
    JOURNAL OF ELECTRICAL SYSTEMS, 2012, 8 (02) : 119 - 131
  • [7] 24-pulse ac-dc converter for harmonic mitigation
    Garg, V.
    Singh, B.
    Bhuvaneswari, G.
    IET POWER ELECTRONICS, 2009, 2 (04) : 364 - 374
  • [8] Harmonic reduction using a novel multipulse AC-DC converter
    Abdollahi, Rohollah
    WORLD JOURNAL OF ENGINEERING, 2018, 15 (04) : 520 - 530
  • [9] Application of Pulse Doubling in Hexagon-Connected Transformer-Based 20-Pulse AC-DC Converter for Power Quality Improvement
    Abdollahi, Rohollah
    Jalilian, Alireza
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (10A): : 153 - 161
  • [10] GENERALIZED METHOD OF HARMONIC REDUCTION IN AC-DC CONVERTERS BY HARMONIC CURRENT INJECTION
    AMETANI, A
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1972, 119 (07): : 857 - +