Application of monolithic capillary half focusing X-ray lens in micro-EXAFS analytical technology

被引:0
|
作者
Sun Tian-Xi [1 ]
Liu Zhi-Guo
Wei Shi-Qiang
He Bo
Wei Zheng
Yang Jun
Zeng Yi
Lin Xiao-Yan
Chu Xue-Lian
Ding Xun-Liang
机构
[1] Beijing Normal Univ, Beijing Radiat Ctr, Inst Low Energy Nucl Phys, Minist Educ,Key Lab Beam Technol & Mat Modificat, Beijing 100875, Peoples R China
[2] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Peoples R China
关键词
capillary X-ray optics; synchrotron radiation; micro-EXAFS;
D O I
暂无
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A monolithic capillary half focusing X-ray lens (MCHFXRL) is used to focus the synchrotron radiation. The magnitudes of the focal spot size and gain of the synchrotron radiation microbeam focused by the MCHFXRL are in the orders of 10 mu m and 10(3), respectively. In the energy range from 5.5 to 11.5keV, the focal spot size varies from 88 to 29 mu m; the transmission efficiency varies from 26.1% to 20.5%; the translation of the vertical position of the focal spot is 3 mu m; the change of the output focal distance is 155 mu m. On the basis of the investigation of the performances of the MCHFXRL, the application of the synchrotron radiation microbeam in micro-extended-X-ray-absorption-fine-structure (micro-EXAFS) analysis is studied.
引用
收藏
页码:967 / 971
页数:5
相关论文
共 21 条
  • [1] Micro-X-ray absorption near edge structure spectroscopy investigations of baroque tin-amalgam mirrors at BESSY using a capillary focusing system
    Bartoll, J
    Röhrs, S
    Erko, A
    Firsov, A
    Bjeoumikhov, A
    Langhoff, N
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1587 - 1592
  • [2] Polycapillary optics for energy dispersive micro x-ray diffractometry
    Bjeoumikhov, A
    Bjeoumikhova, S
    Langhoff, N
    Wedell, R
    [J]. APPLIED PHYSICS LETTERS, 2005, 86 (14) : 1 - 3
  • [3] Monolithic polycapillary x-ray optics engineered to meet a wide range of applications
    Ding, X
    Gao, N
    Havrilla, G
    [J]. ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS, 2000, 4144 : 174 - 182
  • [4] DING X, 1997, J TRACE MICROPROBE T, V15, P647
  • [5] Ding XL, 1997, X-RAY SPECTROM, V26, P374
  • [6] High energy resolution XRMF spectrometer using polycapillary x-ray optics and PSPC
    Ding, XL
    Liu, ZG
    Yan, YM
    Pan, QL
    [J]. X-RAY SPECTROMETRY, 2004, 33 (01) : 67 - 73
  • [7] X-ray spectrometry using polycapillary X-ray optics and position sensitive detector
    Ding, XL
    Xie, JD
    He, YJ
    Pan, QL
    Yan, YM
    [J]. TALANTA, 2000, 53 (01) : 17 - 22
  • [8] DING XL, 1998, P JAP CHIN JOINT SEM, P112
  • [9] DING XL, 1995, J BEIJING NORMAL U S, V31, P75
  • [10] DING XL, 1995, J BEIJING NORMAL U S, V31, P40