The Highly Effective EMI Shielding Materials for Electric and Magnetic Fields over the Wide Range of Frequency in Near-Field Region

被引:7
|
作者
Kim, Yoon-Hyun [1 ]
Joo, Kisu [1 ]
Lee, Kyu Jae [1 ]
Hwang, Jung Woo [1 ]
Lee, Seung Jae
Jeong, Se Young [1 ]
Park, Hyun Ho [2 ]
机构
[1] Ntrium Inc, 54-42 Dongtanhana 1 Gil, Hwaseong Si, Gyeonggi Do, South Korea
[2] Univ Suwon, Dept Elect Engn, Hwaseong 18323, South Korea
关键词
EMI shielding; spray; near field shielding efeectiveness; hybridpaste;
D O I
10.1109/ECTC.2019.00116
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effects of the electrical resistivity and permeability of conductive paste and magnetic paste materials on the near-field shielding effectiveness (SE) were investigated using strip-line and loop-probe methods. The silver paste of 3.4 x 10(-5) Omega . cm of volume resistivity showed more than 30dB of electric field SE and the SE increased as the thickness of conductive layer increased. For the magnetic field SE showed max 60dB as the thickness increased. However, in low frequency below 10MHz, the magnetic field SE was max 3dB in the case of 10 mu m thickness. Magnetic sheets made of soft magnetic materials having permeability of 200 mu showed 11dB of magnetic field SE at 1MHz. The hybrid paste having conductivity of 1.8 x 10(-4) Omega . cm and permeability of 23.7 mu showed SE of 13.5dB for the magnetic field and 63.9dB for electric field at 10MHz, respectively. The paste having conductivity of 3.7 x 10(-2) Omega . cm and permeability of 53.4 mu, showed 7.6dB for magnetic field at 10MHz. In low frequency below 10MHz, the permeability had dominant influence on the magnetic field shielding in the near-field region. As the frequency increases, the SE is mainly affected by the conductivity of hybrid pastes.
引用
收藏
页码:733 / 739
页数:7
相关论文
共 34 条
  • [1] Optimized CdTe sensors for measurement of electric and magnetic fields in the near-field region
    Cecelja, F
    Balachandran, W
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (03) : 483 - 487
  • [2] An Effective Source Reconstruction Method of EMI Sources in Shielding Based on Phaseless Near-Field Scanning
    Song, Tian-Hao
    Wei, Xing-Chang
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [3] Comparative Study of Electric and Magnetic Losses in Shielding Materials for Far-Field and Near-Field Electromagnetic Interference Suppression
    Qi, Zhi-Yang
    Tang, Liu
    Yi, Da
    Tang, Ming-Chun
    2021 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON ADVANCED MATERIALS AND PROCESSES FOR RF AND THZ APPLICATIONS (IMWS-AMP), 2021, : 284 - 286
  • [4] Homogenization of Metal Grid Reinforced Composites for Near-Field Low Frequency Magnetic Shielding
    Al Achkar, Ghida
    Pichon, Lionel
    Bensetti, Mohamed
    Daniel, Laurent
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 99 : 153 - 163
  • [5] Homogenization of metal grid reinforced composites for near-field low frequency magnetic shielding
    Achkar G.A.
    Pichon L.
    Bensetti M.
    Daniel L.
    Progress In Electromagnetics Research M, 2021, 99 : 153 - 163
  • [6] Simultaneous Measurement of Electric and Magnetic Fields With a Dual Probe for Efficient Near-Field Scanning
    Shao, Weiheng
    Fang, Wenxiao
    Huang, Yun
    Li, Guangwei
    Wang, Lei
    He, Zhiyuan
    Shao, E.
    Guo, Yuandong
    En, Yunfei
    Yao, Bin
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2019, 67 (04) : 2859 - 2864
  • [7] Closed-Form Expressions of Electric and Magnetic Near-Fields for the Calibration of Near-Field Probes
    Boyer, A.
    Nolhier, N.
    Caignet, F.
    Dhia, S. Ben
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [8] Near-field microwave magnetic nanoscopy of superconducting radio frequency cavity materials
    Tai, Tamin
    Ghamsari, Behnood G.
    Bieler, Thomas R.
    Tan, Teng
    Xi, X. X.
    Anlage, Steven M.
    APPLIED PHYSICS LETTERS, 2014, 104 (23)
  • [9] Optimized CdTe sensors for measurement of electric and magnetic fields in the near field region
    Cecelja, Franjo
    Balachandran, W.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1999, 1 : 279 - 284
  • [10] Optimised CdTe sensors for measurement of electric and magnetic fields in the near field region
    Cecelja, F
    Balachandran, W
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 279 - 284