Objective: Endovascular coil embolization has become an effective treatment modality for most intracranial aneurysms. However, complex aneurysms including large and giant aneurysms, fusiform shaped aneurysms, wide necked aneurysm, or small aneurysm that are unsuitable for coil embolization are still deterrent to be treated. Flow diversion is a novel concept that is applied in the treatment of these complex intracranial aneurysms. Method: We review the results and important features of 25 aneurysms in 24 patients who underwent endovascular treatment by using the pipeline flow-diverter embolization device. Result: At 6 month follow-up, all aneurysms (100%) showed total occlusion in our series. Only one patient who had giant vertebrobasilar aneurysm experienced major complication related to endovascular treatment. Discussion: We suggest that parent artery reconstruction via flow diversion with the PED is a valid and safe treatment modality.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [1] Flow-diverter Embolization for Tandem Intracranial Aneurysms: A Single Center Experience
    Cerejo, Russell
    John, Seby
    Bauer, Andrew
    Bain, Mark
    Masaryk, Thomas
    Hussain, Muhammad S.
    Toth, Gabor
    STROKE, 2017, 48
  • [2] Treatment of Intracranial Aneurysms Using the Pipeline Flow-Diverter Embolization Device: A Single-Center Experience with Long-Term Follow-Up Results
    Saatci, I.
    Yavuz, K.
    Ozer, C.
    Geyik, S.
    Cekirge, H. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (08) : 1436 - 1446
  • [3] Treatment of intracranial aneurysms with pipeline embolization device: a single-center experience
    Liang, Wenbao
    Yin, Jiaqi
    Lu, Chenyu
    Yang, Jianbo
    Ma, Xiaoqiang
    Zhang, Xin
    Turhon, Mirzat
    Yang, Xinling
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (04) : 2916 - 2926
  • [4] Pipeline Flow-Diverter Stent for Endovascular Treatment of Intracranial Aneurysms: Preliminary Experience in 20 Patients with 27 Aneurysms
    Lubicz, Boris
    Collignon, Laurent
    Raphaeli, Gai
    De Witte, Olivier
    WORLD NEUROSURGERY, 2011, 76 (1-2) : 114 - 119
  • [5] Flow-diverter stent to manage intracranial aneurysms: A single center experience
    Feng, Shao-Wei
    Luo, Chao-Bao
    Lee, Chien-Hui
    Chang, Feng-Chi
    Lin, Chung-Jung
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (03) : 358 - 363
  • [6] Endovascular treatment of intracranial aneurysms with flow-diverter stents: preliminary single-centre experience
    Malatesta, Emanuele
    Nuzzi, Nunzio Paolo
    Divenuto, Ignazio
    Fossaceca, Rita
    Lombardi, Mariangela
    Cerini, Paolo
    Guzzardi, Giuseppe
    Stecco, Alessandro
    Andreula, Cosma
    Carriero, Alessandro
    RADIOLOGIA MEDICA, 2013, 118 (06): : 971 - 983
  • [7] Endovascular Treatment of Ruptured Intracranial Aneurysms with Pipeline™ Flow-Diverter Stent: Pros and Cons
    Lylyk, Pedro
    Pabon, Boris
    Ferrario, Angel
    Scrivano, Esteban
    Lundquist, Javier
    Ceratto, Rosana
    Nella, Rodolfo
    JOURNAL OF NEUROSURGERY, 2010, 113 (02) : A433 - A434
  • [8] Silk flow diverter in the treatment of complex intracranial aneurysms: a single-center experience with 60 patients
    Ido Strauss
    Shimon Maimon
    Acta Neurochirurgica, 2016, 158 : 247 - 254
  • [9] Silk flow diverter in the treatment of complex intracranial aneurysms: a single-center experience with 60 patients
    Strauss, Ido
    Maimon, Shimon
    ACTA NEUROCHIRURGICA, 2016, 158 (02) : 247 - 254
  • [10] The Silk flow-diverter stent for endovascular treatment of intracranial aneurysms
    Alghamdi, Faisal
    Morais, Ricardo
    Scillia, Pietro
    Lubicz, Boris
    EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (06) : 753 - 762