Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution

被引:28
|
作者
Blissitt, KJ [1 ]
Young, LE [1 ]
Jones, RS [1 ]
Darke, PGG [1 ]
Utting, J [1 ]
机构
[1] ROYAL LIVERPOOL UNIV HOSP, DEPT ANAESTHESIA, LIVERPOOL L69 3BX, MERSEYSIDE, ENGLAND
关键词
horse; Doppler; echocardiography; thermodilution; cardiac output;
D O I
10.1111/j.2042-3306.1997.tb01631.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Measurements of cardiac output by Doppler echocardiography were compared to simultaneous measurements by thermodilution in 9 conscious horses. In the Doppler technique, mean blood flow velocities for estimation of cardiac output were recorded from the aorta and pulmonary artery, The flow area of each vessel was calculated from the vessel diameter, measured from a 2-dimensional ultrasound image. Differences in the site and method of measuring the vessel diameter altered the estimation of cardiac output by the Doppler method, Cardiac output was modified by the i.v. infusion of 4 mu g/kg bwt/min dopamine and 4 mu g/kg bwt/min dobutamine and by the i.v. administration of 10 mu g/kg bwt detomidine and 20 mu g/kg bwt butorphanol, Doppler measurements of cardiac output correlated closely with measurement by thermodilution. Measurements from the aortic outflow correlated more closely with thermodilution, than those from the pulmonary artery (r = 0.89 and r = 0.77, respectively), Doppler measurements agreed most closely with thermodilution measurements when the mean flow velocity was recorded from the aorta and the flow area was measured from the ascending aorta using the leading edge method, There was no significant bias between the 2 techniques when Doppler flow velocities were recorded by this method and the limits of agreement were narrow (+/- 12.26 l/min). The differences between the 2 methods increased with increasing cardiac output. Doppler echocardiography is a safe noninvasive method of measuring cardiac output in horses, The agreement between Doppler echocardiography and thermodilution in this study is similar to that reported in man and is similar to that reported between thermodilution and other techniques in man.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 50 条
  • [1] Measurement of cardiac output by transoesophageal Doppler echocardiography in anaesthetized horses: Comparison with thermodilution
    Young, LE
    Blissitt, KJ
    Bartram, DH
    Clutton, RE
    Molony, V
    Jones, RS
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (06) : 773 - 780
  • [2] Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses
    Linton, RA
    Young, LE
    Marlin, DJ
    Blissitt, KJ
    Brearley, JC
    Jonas, MM
    O'Brien, TK
    Linton, NW
    Band, DM
    Hollingworth, C
    Jones, RS
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2000, 61 (07) : 731 - 737
  • [3] Measurement of cardiac output by transoesophageal echocardiography: A comparison of two Doppler methods with thermodilution
    Royse, CF
    Royse, AG
    Blake, DW
    Grigg, LE
    [J]. ANAESTHESIA AND INTENSIVE CARE, 1999, 27 (06) : 586 - 590
  • [4] Comparison of Fick and thermodilution cardiac output determinations in standing horses
    Lepiz, Mauricio Loria
    Keegan, Robert D.
    Bayly, Warwick M.
    Greene, Stephen A.
    McEwen, Margaret-Mary
    [J]. RESEARCH IN VETERINARY SCIENCE, 2008, 85 (02) : 307 - 314
  • [5] Doppler and Volumetric Echocardiographic Methods for Cardiac Output Measurement in Standing Adult Horses
    McConachie, E.
    Barton, M. H.
    Rapoport, G.
    Giguere, S.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2013, 27 (02) : 324 - 330
  • [6] DOPPLER AND VOLUMETRIC ECHOCARDIOGRAPHIC METHODS FOR CARDIAC OUTPUT MEASUREMENT IN STANDING ADULT HORSES
    McConachie, E.
    Barton, M. H.
    Rapoport, G.
    Giguere, S.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2012, 26 (03) : 727 - 727
  • [7] Agreement of Bioreactance Cardiac Output Monitoring With Thermodilution in Healthy Standing Horses
    Hopster, Klaus
    Hurcombe, Samuel D. A.
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2021, 8
  • [8] MEASUREMENT OF CARDIAC-OUTPUT - TRANSTRACHEAL DOPPLER VERSUS THERMODILUTION
    FROESE, N
    FRIESEN, R
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (07): : 931 - 934
  • [9] COMPARISON OF METHODS OF CARDIAC-OUTPUT MEASUREMENTS DETERMINED BY DYE DILUTION, PULSED DOPPLER-ECHOCARDIOGRAPHY AND THERMODILUTION IN HORSES
    MIZUNO, Y
    AIDA, H
    HARA, H
    FUJINAGA, T
    HAGIO, M
    [J]. JOURNAL OF VETERINARY MEDICAL SCIENCE, 1994, 56 (01): : 1 - 5
  • [10] SIMULTANEOUS INTRAOPERATIVE MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION AND TRANSTRACHEAL DOPPLER
    SIEGEL, LC
    FITZGERALD, DC
    ENGSTROM, RH
    [J]. ANESTHESIOLOGY, 1991, 74 (04) : 664 - 669