Sanitary and bacteriological examinations of Lake Oswin water

被引:0
|
作者
Zmyslowska, I [1 ]
Golas, I [1 ]
机构
[1] Univ Warmia & Mazury, Dept Environm Microbiol, PL-10957 Olsztyn, Poland
来源
关键词
nature reserve; lake; water; bacteria; sanitary and bacteriological indicators;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The investigation was carried out in the "Seven Islands" nature reserve. It has been discovered that in the spring. summer and autumn the number of determined pollution degree indicator bacteria (TVC 22degreesC and TVC 37degreesC) of the water of Lake Oswin ranged from tens to thousands of CFU per I ml, depending on the research station. The sanitary state indicator bacteria (TC, FC, FS) occurred from single cells to several hundred thousand cells per 100 ml of water. In 36.5% of the lake water samples, the FC:FS ratio was determined as higher than 4.0, but it also ranged from 0.7 to 4.0. In 18% of Lake Oswin water samples it ranged front 0.043 to 0.7, and in 9% it was lower than 0.043. This proves excretal contamination with prevailing excrements of human origin.
引用
收藏
页码:351 / 356
页数:6
相关论文