Speciation of Mn(II) and Mn(VII) by on-line spectrophotornetric sequential injection analysis

被引:28
|
作者
van Staden, JF [1 ]
Mulaudzi, LV [1 ]
Stefan, RI [1 ]
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
关键词
speciation; Mn(II); Mn(VII); on-line; sequential injection analysis; 4-(2-pyridylazo) resorcinol;
D O I
10.1016/S0003-2670(03)00883-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line sequential injection analysis system with spectrophotometric detection using 4-(2-pyridylazo) resorcinol as reagent is proposed for the speciation of Mn(II) and Mn(VII). The sampling frequency is 30 determinations per hour. The linear range for Mn(II) is 0.020-0.500 mg/l with a detection limit of 0.005 mg/l and for total Mn 0.025-0.550 mg/l with a detection limit of 0.008 mg/l. The % RSD is 0.27 and 0.34 for Mn(II) and Mn(VII), respectively (n = 10). Chemical masking of Fe and Al was achieved by on-line addition of a 0.1 mol/l NaF solution. The proposed system yielded results that compare very well with standard methods. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 50 条
  • [1] Determination of Mn(II) and Mn(VII) by chemiluminescence analysis
    Lu, Xiaohu
    Lu, Minggang
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 1992, 12 (05): : 121 - 122
  • [2] On-line speciation of bromine and bromide using sequential injection analysis with spectrophotometric detection
    J. F. van Staden
    L. V. Mulaudzi
    R. I. Stefan
    Analytical and Bioanalytical Chemistry, 2003, 375 : 1074 - 1082
  • [3] On-line speciation of bromine and bromide using sequential injection analysis with spectrophotometric detection
    van Staden, JF
    Mulaudzi, LV
    Stefan, RI
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (08) : 1074 - 1082
  • [4] On-line speciation analysis of inorganic arsenic in complex environmental aqueous samples by pervaporation sequential injection analysis
    Boonjob, Warunya
    Miro, Manuel
    Kolev, Spas D.
    TALANTA, 2013, 117 : 8 - 13
  • [5] On-line dyebath monitoring by sequential injection analysis
    Draper, Sara L.
    Beck, Keith R.
    Smith, Brent
    AATCC Magazine, 2001, 1 (01): : 24 - 28
  • [6] On-line dyebath monitoring by sequential injection analysis
    Draper, SL
    Beck, KR
    Smith, B
    AATCC REVIEW, 2001, 1 (01) : 24 - 28
  • [7] Development of a sequential injection analysis device and its application for the determination of Mn(II) in water
    Lai, Zhiwei
    Lin, Fangyuan
    Qiu, Linghang
    Wang, Yiru
    Chen, Xi
    Hu, Hao
    TALANTA, 2020, 211
  • [8] Speciation of Mn(II), Mn(VII) and total manganese in water and food samples by coprecipitation-atomic absorption spectrometry combination
    Citak, Demirhan
    Tuzen, Mustafa
    Soylak, Mustafa
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 173 (1-3) : 773 - 777
  • [9] On-line monitoring of glucose and penicillin by sequential injection analysis
    Min, RW
    Nielsen, J
    Villadsen, J
    ANALYTICA CHIMICA ACTA, 1996, 320 (2-3) : 199 - 205
  • [10] On-line monitoring of lipolytic activity by sequential injection analysis
    Cos, O
    Montesinos, JL
    Lafuente, J
    Solà, C
    Valero, F
    BIOTECHNOLOGY LETTERS, 2000, 22 (22) : 1783 - 1788