Biomolecular screening of formylpeptide receptor ligands with a sensitive, quantitative, high-throughput flow cytometry platform

被引:21
|
作者
Edwards, Bruce S. [1 ]
Young, Susan M.
Oprea, Tudor I.
Bologa, Cristian G.
Prossnitz, Eric R.
Sklar, Larry A.
机构
[1] Univ New Mexico, Hlth Sci Ctr, Dept Pathol, Ctr Canc Res, Albuquerque, NM 87131 USA
[2] Univ New Mexico, Div Biocomputing, Albuquerque, NM 87131 USA
[3] Univ New Mexico, Hlth Sci Ctr, Albuquerque, NM 87131 USA
关键词
D O I
10.1038/nprot.2006.9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The formylpeptide receptor (FPR) family of G protein - coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. Here we describe a high-throughput flow cytometry screening approach that has successfully identified multiple families of previously unknown FPR ligands. The assay detects active structures that block the binding of a fluorescent ligand to membrane FPR of intact cells, thus detecting both agonists and antagonists. It is homogeneous in that assay reagents are added in sequence and the wells are subsequently analyzed without intervening wash steps. Microplate wells are routinely processed at a rate of 40 wells per minute, requiring a volume of only 2 mu l to be sampled from each. This screening approach has recently been extended to identify a high-affinity, selective agonist for the intracellular estrogen-binding G protein coupled receptor GPR30. With the development of appropriate assay reagents, it may be generally adaptable to a wide range of receptors. The total time required for the assay ranges between 1.5 and 2.5 h. The time required for flow cytometry analysis of a 96-well plate at the end of the procedure is less than 2.5 min. By comparison, manual processing of 96 samples will typically require 40 - 50 min, and a fast commercial automated sampler processes 96-well plates in less than 15 min, requiring the aspiration of 22 mu l per sample for an analysis volume of 2 mu l.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [1] Biomolecular screening of formylpeptide receptor ligands with a sensitive, quantitative, high-throughput flow cytometry platform
    Bruce S Edwards
    Susan M Young
    Tudor I Oprea
    Cristian G Bologa
    Eric R Prossnitz
    Larry A Sklar
    Nature Protocols, 2006, 1 : 59 - 66
  • [2] High-throughput screening with HyperCyt® flow cytometry to detect small molecule formylpeptide receptor ligands
    Young, SM
    Bologa, C
    Prossnitz, ER
    Oprea, TI
    Sklar, LA
    Edwards, BS
    JOURNAL OF BIOMOLECULAR SCREENING, 2005, 10 (04) : 374 - 382
  • [3] Integration of virtual screening with high-throughput flow cytometry to identify novel small molecule formylpeptide receptor antagonists
    Edwards, BS
    Bologa, C
    Young, SM
    Balakin, KV
    Prossnitz, ER
    Savchuck, NP
    Sklar, LA
    Oprea, TI
    MOLECULAR PHARMACOLOGY, 2005, 68 (05) : 1301 - 1310
  • [4] Duplex High-Throughput Flow Cytometry Screen Identifies Two Novel Formylpeptide Receptor Family Probes
    Young, Susan M.
    Bologa, Cristian M.
    Fara, Dan
    Bryant, Bj K.
    Strouse, Juan Jacob
    Arterburn, Jeffrey B.
    Ye, Richard D.
    Oprea, Tudor I.
    Prossnitz, Eric R.
    Sklar, Larry A.
    Edwards, Bruce S.
    CYTOMETRY PART A, 2009, 75A (03) : 253 - 263
  • [5] Flow cytometry for drug discovery, receptor pharmacology and high-throughput screening
    Sklar, Larry A.
    Carter, Mark B.
    Edwards, Bruce S.
    CURRENT OPINION IN PHARMACOLOGY, 2007, 7 (05) : 527 - 534
  • [6] A Robotic Platform for Quantitative High-Throughput Screening
    Michael, Sam
    Auld, Douglas
    Klumpp, Carleen
    Jadhav, Ajit
    Zheng, Wei
    Thorne, Natasha
    Austin, Christopher P.
    Inglese, James
    Simeonov, Anton
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2008, 6 (05) : 637 - 657
  • [7] Flow cytometry for high-throughput, high-content screening
    Edwards, BS
    Oprea, T
    Prossnitz, ER
    Sklar, LA
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2004, 8 (04) : 392 - 398
  • [8] Screening with HyperCyt® high-throughput flow cytometry to detect small-molecule formyl-peptide receptor ligands
    Edwards, BS
    Young, SM
    Waller, A
    Bologa, C
    Oprea, T
    Prossnitz, ER
    Sklar, LA
    CYTOMETRY PART A, 2004, 59A (01): : 31 - 32
  • [9] High-Throughput Flow Cytometry
    Robinson, J. Paul
    Patsekin, Valery
    Rajwa, Bartek
    Davisson, V. Jo
    Li, Nianyu
    Narayanan, Padmakumar
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2011, 31 (08): : 20 - +
  • [10] A Fluorescent Hydrogel-Based Flow Cytometry High-Throughput Screening Platform for Hydrolytic Enzymes
    Pitzler, Christian
    Wirtz, Georgette
    Vojcic, Ljubica
    Hiltl, Stephanie
    Boeker, Alexander
    Martinez, Ronny
    Schwaneberg, Ulrich
    CHEMISTRY & BIOLOGY, 2014, 21 (12): : 1733 - 1742