Development of a Material Sparing Bulk Density Test Comparable to a Standard USP Method for Use in Early Development of API's

被引:9
|
作者
Hughes, Helen [1 ]
Leane, Michael M. [1 ]
Tobyn, Michael [1 ]
Gamble, John F. [1 ]
Munoz, Santiago [2 ]
Musembi, Pauline [1 ]
机构
[1] Bristol Myers Squibb Co, Drug Prod Sci & Technol, Wirral CH46 1QW, Merseyside, England
[2] Bristol Myers Squibb Co, Global Mfg & Supply, Swords, Dublin, Ireland
来源
AAPS PHARMSCITECH | 2015年 / 16卷 / 01期
关键词
active pharmaceutical ingredient (API); bulk density; compressibility index; excipients; pharmaceuticals; COHESIVE POWDERS;
D O I
10.1208/s12249-014-0215-7
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Bulk density can be a key indicator of performance, and may influence choice of formulation route of materials in pharmaceutical development. During early development, the cost of API's can be expensive and the availability of material for powder property analysis is limited. The aim of this work was to investigate a suitable small-scale, low material requirement, bulk density test which would provide comparable data to the recommended large volume USP test. Materials with a range of morphological characteristics typically seen in the pharmaceutical industry were assessed to ensure that methods were suitably robust. It was found that the USP II "low volume" test does not give equivalent results to other tests in the USP, across the range of materials. An alternative test based on the FT4 powder rheometer at a scale of 25 mL gave results equivalent to the large volume USP I standard test. The use of smaller 10-mL methods was also found to give acceptable results for materials that were considered well-behaved but were more variable with difficult to handle materials with low bulk density.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 5 条
  • [1] Development of a Material Sparing Bulk Density Test Comparable to a Standard USP Method for Use in Early Development of API’s
    Helen Hughes
    Michael M. Leane
    Michael Tobyn
    John F. Gamble
    Santiago Munoz
    Pauline Musembi
    AAPS PharmSciTech, 2015, 16 : 165 - 170
  • [2] Development of a Standard Test Method for Assessing Mechanical Penetration of Personal Protective Equipment Material to Test Soils by Simulating Actual Use
    Schwerin, Matthew R.
    Lucas, Anne D.
    Woods, Terry O.
    JOURNAL OF TESTING AND EVALUATION, 2022, 50 (01) : 275 - 283
  • [3] THE USE OF MOIRE INTERFEROMETRY AS AN AID TO STANDARD TEST-METHOD DEVELOPMENT FOR TEXTILE COMPOSITE-MATERIALS
    IFJU, PG
    MASTERS, JE
    JACKSON, WC
    COMPOSITES SCIENCE AND TECHNOLOGY, 1995, 53 (02) : 155 - 163
  • [4] Holistic Metabolomic Laboratory-Developed Test (LDT): Development and Use for the Diagnosis of Early-Stage Parkinson's Disease
    Lokhov, Petr G.
    Maslov, Dmitry L.
    Lichtenberg, Steven
    Trifonova, Oxana P.
    Balashova, Elena E.
    METABOLITES, 2021, 11 (01) : 1 - 16
  • [5] DEVELOPMENT OF EARLY POSTISCHEMIC INJURY IN THE LIVER AS EVALUATED BY A DOUBLE STAINING METHOD COMBINING AN INTRAVITAL DYE EXCLUSION TEST AND ALIZARIN RED-S
    JENNISCHE, E
    ACTA PATHOLOGICA MICROBIOLOGICA ET IMMUNOLOGICA SCANDINAVICA SECTION A-PATHOLOGY, 1985, 93 (06): : 359 - 365