Diagnostic value of contrast-enhanced ultrasound in solid thyroid nodules with and without enhancement

被引:58
|
作者
Wu, Qiong [1 ]
Wang, Yan [1 ]
Li, Yi [1 ]
Hu, Bing [1 ]
He, Zhi-Yan [2 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Inst Ultrasound Med, Dept Ultrasound Med, Affiliated Peoples Hosp 6, 600 Yishan Rd, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Radiol, Affiliated Peoples Hosp 1, Shanghai, Peoples R China
关键词
Thyroid nodules; Contrast-enhanced ultrasound; Conventional ultrasound; Sonographic features; QUANTITATIVE-EVALUATION; LESIONS; CEUS; DIFFERENTIATION; ULTRASONOGRAPHY; ELASTOGRAPHY; MANAGEMENT; DOPPLER; BENIGN;
D O I
10.1007/s12020-015-0850-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to investigate different enhancement patterns of solid thyroid nodules on contrast-enhanced ultrasound (CEUS) and then to evaluate the corresponding diagnostic performance in the differentiation of benign and malignant nodules with and without enhancement. 229 solid thyroid nodules in 196 patients who had undergone both conventional ultrasound and CEUS examinations were classified into enhancement and non-enhancement groups. Besides, different enhancement patterns in the enhancement group were characterised with five indicators including arrival time, mode of entrance, echo intensity, homogeneity, and washout time. Then aforementioned indicators were compared between benign and malignant nodules of different sizes (< 10 mm and > 10 mm), and diagnostic performance of significant enhancement indicators was calculated. As for the enhancement group, there were statistically significant differences of < 10 mm subgroup among three CEUS indicators including arrival time, mode of entrance, and washout time between malignant and benign thyroid nodules (p < 0.05), while all CEUS indicators showed statistically significant differences in the total group and a parts per thousand yen10 mm subgroup (p < 0.05). All the five CEUS indicators displayed better diagnostic performance with specificity (92.86, 92.14, 95.71, 90.71, and 90.71 %, respectively) and diagnostic accuracy (80.79, 79.48, 74.67, 75.11, and 81.66 %, respectively), while the sensitivity and negative predictive value of non-enhancement were 95.51 and 95.83 %, respectively, with an accuracy of 77.29 %. CEUS is a very promising diagnostic technique that could improve the diagnostic accuracy of identifying benign thyroid lesions to spare a large number of patients an unnecessary invasive procedure.
引用
下载
收藏
页码:480 / 488
页数:9
相关论文
共 50 条
  • [1] Diagnostic value of contrast-enhanced ultrasound in solid thyroid nodules with and without enhancement
    Qiong Wu
    Yan Wang
    Yi Li
    Bing Hu
    Zhi-Yan He
    Endocrine, 2016, 53 : 480 - 488
  • [2] Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification
    Jiang, Jue
    Shang, Xu
    Wang, Hua
    Xu, Yong-Bo
    Gao, Ya
    Zhou, Qi
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2015, 31 (03): : 138 - 144
  • [3] Diagnostic Accuracy of Contrast-Enhanced Ultrasound Enhancement Patterns for Thyroid Nodules
    Zhang, Yan
    Luo, Yu-kun
    Zhang, Ming-bo
    Li, Jie
    Li, Junlai
    Tang, Jie
    MEDICAL SCIENCE MONITOR, 2016, 22 : 4755 - 4764
  • [4] Diagnostic value of "absent" pattern in contrast-enhanced ultrasound for the differentiation of thyroid nodules
    Wu, Qiong
    Li, Yi
    Wang, Yan
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 63 (04) : 325 - 334
  • [5] Value of Contrast-Enhanced Ultrasound in Mummified Thyroid Nodules
    Chen, Sijie
    Tang, Kui
    Gong, Yi
    Ye, Fei
    Liao, Liyan
    Li, Xiaodu
    Zhang, Qi
    Xu, Yan
    Zhang, Rongsen
    Niu, Chengcheng
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [6] Diagnostic value of contrast-enhanced ultrasound in papillary thyroid microcarcinoma
    Chen, Hong Yan
    Liu, Wei Yan
    Zhu, Hui
    Jiang, Dao Wen
    Wang, Dong Hua
    Chen, Yongqi
    Li, Weihua
    Pan, Gaofeng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 11 (05) : 1555 - 1562
  • [7] Contrast-enhanced ultrasound in the diagnosis of solitary thyroid nodules
    Zhang Yuan
    Jiang Quan
    Zhang Yunxiao
    Chen Jian
    He Zhu
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (01) : 41 - 45
  • [8] Utility of Contrast-Enhanced Ultrasound for Evaluation of Thyroid Nodules
    Zhang, Bo
    Jiang, Yu-Xin
    Liu, Ji-Bin
    Yang, Meng
    Dai, Qing
    Zhu, Qing-Li
    Gao, Pin
    THYROID, 2010, 20 (01) : 51 - 57
  • [9] Application of contrast-enhanced ultrasound for evaluation of thyroid nodules
    Zhan, Jia
    Ding, Hong
    ULTRASONOGRAPHY, 2018, 37 (04) : 288 - 297
  • [10] Diagnostic Efficiency of Quantitative Contrast-Enhanced Ultrasound Indicators for Discriminating Benign From Malignant Solid Thyroid Nodules
    Zhou, Xiaohui
    Zhou, Ping
    Hu, Zheyu
    Tian, Shuang Ming
    Zhao, Yongfeng
    Liu, Wengang
    Jin, Qiuzi
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (02) : 425 - 437