Xenon-neon gas proportional-scintillation counters for X-rays below 2 keV: Experimental results

被引:13
|
作者
Borges, FIGM [1 ]
Santos, FP [1 ]
dos Santos, JMF [1 ]
Dias, THVT [1 ]
Rachinhas, PJBM [1 ]
Conde, CAN [1 ]
机构
[1] Univ Coimbra, Dept Phys, P-3004516 Coimbra, Portugal
关键词
noble gas detectors; soft x-rays; spectra distortion;
D O I
10.1109/TNS.2003.815117
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The energy spectra of. X-rays with energies below 2 keV measured with standard Xe filled gas proportional-scintillation counters at atmospheric pressure exhibit a distorted tail toward the low energy region, due to the loss of electrons to the detector entrance Window. In this framework, a Monte Carlo simulation study taking into account these losses has previously investigated the use of Xe-Ne mixtures as gas proportional scintillation counters (GPSC) fillings. It was shown that the addition of Ne to Xe reduces spectra distortion and improves the overall detector performance. In the present work, we present an experimental study of the performance of a GPSC for different Xe-Ne mixtures and X-ray energies in the 200 to 2000 eV energy range and compare the results with the previously obtained Monte Carlo data.
引用
收藏
页码:842 / 846
页数:5
相关论文
共 38 条
  • [1] Xenon-Neon gas proportional-scintillation counters for x rays below 2 keV: Experimental results
    Borges, FIGM
    Santos, FP
    dos Santos, JMF
    Dias, THVT
    Rachinhas, PJBM
    Conde, CAN
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 181 - 185
  • [2] The energy resolution of xenon-neon filled gas proportional-scintillation counters for x-rays below 2 keV
    Borges, FIGM
    Santos, FP
    Dias, THVT
    Rachinhas, PJBM
    Conde, CAN
    Stauffer, AD
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 294 - 297
  • [3] Xenon-neon gas proportional-scintillation counters for X-rays below 2 keV: A Monte Carlo simulation study
    Borges, FIGM
    Santos, FP
    Dias, THVT
    Rachinhas, PJBM
    Conde, CAN
    Stauffer, AD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 917 - 922
  • [4] Xenon-neon gas proportional scintillation counters: Experimental and simulation results
    Dias, THVT
    Santos, FP
    Rachinhas, PJBM
    Borges, FIGM
    dos Santos, JMF
    Conde, CAN
    Stauffer, AD
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (09) : 6303 - 6312
  • [5] The effect of electron multiplication on the electroluminescence yield of pure xenon and xenon-neon gas proportional scintillation counters: Experimental and simulation results
    Dias, THVT
    Santos, FP
    Rachinhas, PJBM
    Borges, FIGM
    dos Santos, JMF
    Stauffer, AD
    Conde, CAN
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 447 - 451
  • [6] Energy resolution of xenon proportional counters: Monte Carlo and experimental results for 5.9 keV x-rays
    Rachinhas, PJBM
    Dias, THVT
    Santos, FP
    Stauffer, AD
    Conde, CAN
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 90 - 92
  • [7] Light yield and Fano factor for X-rays in xenon gas proportional scintillation counters
    Borges, FIGM
    dosSantos, JMF
    Kubota, S
    Conde, CAN
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 613 - 616
  • [8] PROPERTIES OF GAS SCINTILLATION PROPORTIONAL-COUNTERS FOR SOFT X-RAYS
    INOUE, H
    TANAKA, Y
    TSUNEMI, H
    MATSUOKA, M
    OHASHI, T
    KOYAMA, K
    NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (02): : 295 - 300
  • [9] DETECTION OF SOFT X-RAYS WITH A XENON PROPORTIONAL SCINTILLATION-COUNTER
    POLICARPO, AJ
    ALVES, MAF
    SALETE, M
    LEITE, SCP
    DOSSANTO.MC
    NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (01): : 221 - 226
  • [10] W-value and the Fano factor for x-rays in xenon-neon gas mixtures: a Monte Carlo simulation study
    Santos, F.P.
    Dias, T.H.V.T.
    Rachinhas, P.J.B.M.
    Conde, C.A.N.
    Stauffer, A.D.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 1 : 572 - 576