Deformable image registration and interobserver variation in contour propagation for radiation therapy planning

被引:16
|
作者
Riegel, Adam C. [1 ,2 ]
Antone, Jeffrey G. [1 ]
Zhang, Honglai [1 ,2 ]
Jain, Prachi [1 ]
Raince, Jagdeep [1 ]
Rea, Anthony [1 ]
Bergamo, Angelo M. [1 ]
Kapur, Ajay [1 ,2 ]
Potters, Louis [1 ,2 ]
机构
[1] Northwell Hlth, Dept Radiat Med, Lake Success, NY USA
[2] Hofstra Northwell Sch Med, Hempstead, NY USA
来源
关键词
interobserver variation; deformable image registration; B-spline; contour propagation; BEAM COMPUTED-TOMOGRAPHY; IMRT TREATMENT PLANS; NECK-CANCER; PROSTATE-CANCER; SETUP UNCERTAINTIES; ADAPTIVE RADIOTHERAPY; TARGET DEFINITION; HEAD; MARGIN; VALIDATION;
D O I
10.1120/jacmp.v17i3.6110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Deformable image registration (DIR) and interobserver variation inevitably introduce uncertainty into the treatment planning process. The purpose of the current work was to measure deformable image registration (DIR) errors and interobserver variability for regions of interest (ROIs) in the head and neck and pelvic regions. Measured uncertainties were combined to examine planning margin adequacy for contours propagated for adaptive therapy and to assess the trade-off of DIR and interobserver uncertainty in atlas-based automatic segmentation. Two experienced dosimetrists retrospectively contoured brainstem, spinal cord, anterior oral cavity, larynx, right and left parotids, optic nerves, and eyes on the planning CT (CT1) and attenuation-correction CT of diagnostic PET/CT (CT2) for 30 patients who received radiation therapy for head and neck cancer. Two senior radiation oncology residents retrospectively contoured prostate, bladder, and rectum on the postseed-implant CT (CT1) and planning CT (CT2) for 20 patients who received radiation therapy for prostate cancer. Interobserver variation was measured by calculating mean Hausdorff distances between the two observers' contours. CT2 was deformably registered to CT1 via commercially available multipass B-spline DIR. CT2 contours were propagated and compared with CT1 contours via mean Hausdorff distances. These values were summed in quadrature with interobserver variation for margin analysis and compared with interobserver variation for statistical significance using two-tailed t-tests for independent samples (alpha = 0.05). Combined uncertainty ranged from 1.5-5.8 mm for head and neck structures and 3.1-3.7 mm for pelvic structures. Conventional 5 mm margins may not be adequate to cover this additional uncertainty. DIR uncertainty was significantly less than interobserver variation for four head and neck and one pelvic ROI. DIR uncertainty was not significantly different than interobserver variation for four head and neck and one pelvic ROI. DIR uncertainty was significantly greater than interobserver variation for two head and neck and one pelvic ROI. The introduction of DIR errors may offset any reduction in interobserver variation by using atlas-based automatic segmentation.
引用
收藏
页码:347 / 357
页数:11
相关论文
共 50 条
  • [1] Deformable image registration of CT images for automatic contour propagation in radiation therapy
    Wu, Qian
    Cao, Ruifen
    Pei, Xi
    Jia, Jing
    Hu, Liqin
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S1037 - S1044
  • [2] Therapy: Deformable Image Registration, Contour Propagation, and Dose Mapping
    Brock, K.
    Svensson, S.
    Mlyn, M.
    Fox, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3672 - 3673
  • [3] Evaluation of RayStation Hybrid Deformable Image Registration for Accurate Contour Propagation in Adaptive Planning
    Rong, Y.
    Rao, S.
    Daly, M.
    Wright, C.
    Benedict, S.
    Yamamoto, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3419 - 3419
  • [4] Deformable image registration in radiation therapy
    Dowling, Jason A.
    O'Connor, Laura M.
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 257 - 259
  • [5] DEFORMABLE IMAGE REGISTRATION FOR RADIATION THERAPY
    Sarrut, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S47 - S47
  • [7] Accuracy of deformable image registration for contour propagation in adaptive lung radiotherapy
    Nicholas Hardcastle
    Wouter van Elmpt
    Dirk De Ruysscher
    Karl Bzdusek
    Wolfgang A Tomé
    [J]. Radiation Oncology, 8
  • [8] Accuracy of deformable image registration for contour propagation in adaptive lung radiotherapy
    Hardcastle, Nicholas
    van Elmpt, Wouter
    De Ruysscher, Dirk
    Bzdusek, Karl
    Tome, Wolfgang A.
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [9] Deformable Image Registration, Contour Propagation and Dose Mapping: 101 and 201
    Kessler, M.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] ACCURACY OF DEFORMABLE IMAGE REGISTRATION FOR CONTOUR PROPAGATION IN ADAPTIVE LUNG RADIOTHERAPY
    Hardcastle, N.
    van Elmpt, W.
    Oechsner, M.
    Guckenberger, M.
    De Ruysscher, D.
    Bzdusek, K.
    Tome, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S479 - S479