Evaporator air-side fouling: Effect on performance of room air conditioners and impact on indoor air quality

被引:29
|
作者
Ali, Ahmed Hamza H. [1 ]
Ismail, Ibrahim M. [2 ]
机构
[1] Assiut Univ, Dept Engn Mech, Assiut, Egypt
[2] Assiut Univ, Fac Engn, Assiut, Egypt
来源
HVAC&R RESEARCH | 2008年 / 14卷 / 02期
关键词
D O I
10.1080/10789669.2008.10391004
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigated experimentally the effects of real fouling material at the air side of the evaporator's heat exchanger coil on the performance of room air-conditioner units as well as the impact of some fouling material compositions on indoor air quality. At the end of the experiments, examination of the biological contents of the fouling material on the coil was performed; it was found that the coil frontal face had heavy colonies of Aspergillus fungi of different species. This result is important to fill in the knowledge gaps between biological deposition, colonization, and occupant problems of staying in an environment with a fouled evaporator coil. The results of the effect of such fouling materials on the unit performance show that the unit coefficient of performance at the standard air face velocity of 1.53 m/s for a clean evaporator coil was 2.82. It decreased to 1.89 (67%) after injection of 100 g of fouling materials, dropped to 1.79 (63.4%) after injection of 200 g of fouling materials, and fell to 1.23 (43.6%) after injection of 300 g of fouling materials. However, these results demonstrate that the predominant effect of fouling is to cause significant degradation in a room air conditioner's coefficient of performance.
引用
收藏
页码:209 / 219
页数:11
相关论文
共 50 条
  • [1] The impact of evaporator fouling and filtration on the performance of packaged air conditioners
    Yang, Li
    Braun, James E.
    Groll, Eckhard A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (03): : 506 - 514
  • [2] An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners
    Ahn, YC
    Cho, JM
    Shin, HS
    Hwang, YJ
    Lee, CG
    Lee, JK
    Lee, HU
    Kang, TW
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 20 (05) : 873 - 877
  • [3] Characteristics of air-side particulate fouling materials in finned-tube heat exchangers of air conditioners
    Ahn, YC
    Lee, JK
    [J]. PARTICULATE SCIENCE AND TECHNOLOGY, 2005, 23 (03) : 297 - 307
  • [4] An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners
    Ahn, Young Chull
    Kim, Gil Tae
    Hwang, Yu Jin
    Cheong, Seong Ir
    Lee, Jae-Keun
    [J]. PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 139 - +
  • [5] An experimental study of the air-side particulate fouling in fin-and-tube heat exchangers of air conditioners
    Young-Chull Ahn
    Jae-Min Cho
    Hee-Soo Shin
    Yu-Jin Hwang
    Chang-Gun Lee
    Jae-Keun Lee
    Hyun-Uk Lee
    Tae-Wook Kang
    [J]. Korean Journal of Chemical Engineering, 2003, 20 : 873 - 877
  • [6] Synergistic Impact on Indoor Air Quality: The Combined Use of Air Conditioners, Air Purifiers, and Fresh Air Systems
    Jia, Lizhi
    Ge, Jufeng
    Wang, Zhiqiang
    Jin, Wufeng
    Wang, Congcong
    Dong, Zhanwei
    Wang, Cheng
    Wang, Ren
    [J]. BUILDINGS, 2024, 14 (06)
  • [7] Effect of inlet humidity condition on the air-side performance of an inclined brazed aluminum evaporator
    Kim, MH
    Song, SM
    Bullard, CW
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (05): : 611 - 620
  • [8] Experimental Evaluation of Air-Side Particulate Fouling Performance of Heat Exchangers
    Sun, Yigang
    Zhang, Yuanhui
    Barker, Douglas
    Ford, Steve
    Johnson, Mark
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 1116 - 1130
  • [9] Air-side particulate fouling of heat exchangers in air conditioner evaporators used
    Ahn, YC
    Lee, JK
    Cho, JM
    Shin, HS
    Kang, TW
    Ha, SC
    Lee, HU
    Ahn, SP
    Youn, DH
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 916 - 923
  • [10] Numerical simulation of indoor air environment in bedrooms with room air-conditioners
    College of Civil Engineering, Hunan Univ., Changsha 410082, China
    [J]. Hunan Daxue Xuebao, 2006, 3 (27-32):