Correlation of bispectral index and Guedel's stages of ether anesthesia

被引:9
|
作者
Bhargava, AK [1 ]
Setlur, R [1 ]
Sreevastava, D [1 ]
机构
[1] Armed Forces Med Coll, Dept Anesthesiol & Crit Care, Pune 411040, Maharashtra, India
来源
ANESTHESIA AND ANALGESIA | 2004年 / 98卷 / 01期
关键词
D O I
10.1213/01.ANE.0000090740.32274.72
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bispectral index (BIS) analysis is a method of electroencephalograph (EEG) analysis based on the interfrequency phase relationships of the EEG, designed to quantify anesthetic hypnosis. The BIS was created after concurrent collection of EEG and clinical data from a large number of patients anesthetized with various drugs over a prolonged period and then performing a Fourier analysis followed by a bispectral calculation. The clinical stages of anesthetic depth are very well demonstrated in etherized patients. In this study, we studied the BIS changes during various stages of ether anesthesia and quantified the hypnotic depth during the surgical stage of ether anesthesia. The values for BIS under various stages and planes of ether anesthesia were recorded in 21 patients listed for short surgical procedures. During diethyl ether anesthesia, BIS initially increased and subsequently decreased. During surgical anesthesia, a BIS value of 30 was observed.
引用
下载
收藏
页码:132 / 134
页数:3
相关论文
共 50 条
  • [1] The effect of different stages of neuromuscular block on the bispectral index and the bispectral index-XP under remifentanil/propofol anesthesia
    Dahaba, AA
    Mattweber, M
    Fuchs, A
    Zenz, W
    Rehak, PH
    List, WF
    Metzler, H
    ANESTHESIA AND ANALGESIA, 2004, 99 (03): : 781 - 787
  • [2] Anesthesia awareness and the bispectral index
    Avidan, Michael S.
    Zhang, Lini
    Burnside, Beth A.
    Finkel, Kevin J.
    Searleman, Adam C.
    Selvidge, Jacqueline A.
    Saager, Leif
    Turner, Michelle S.
    Rao, Srikar
    Bottros, Michael
    Hantler, Charles
    Jacobsohn, Eric
    Evers, Alex S.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (11): : 1097 - 1108
  • [3] Correlation between bispectral index and patient state index in children under sevoflurane anesthesia
    Kim, Doyeon
    Kim, Jaeyoun
    Kim, Inho
    Gil, Nam-Su
    Shin, Young Hee
    Jeong, Ji Seon
    PEDIATRIC ANESTHESIA, 2022, 32 (06) : 740 - 746
  • [4] Monitors of the hypnotic component of anesthesia - Correlation between bispectral index and cerebral state index
    Pilge, S.
    Kreuzer, M.
    Kochs, E. F.
    Zanner, R.
    Paprotny, S.
    Schneider, G.
    MINERVA ANESTESIOLOGICA, 2012, 78 (06) : 636 - 645
  • [5] Depth of anesthesia and bispectral index monitoring
    Kissin, I
    ANESTHESIA AND ANALGESIA, 2000, 90 (05): : 1114 - 1117
  • [6] Anesthesia awareness and the bispectral index - Reply
    Avidan, Michael S.
    Searleman, Adam C.
    Evers, Alex S.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (04): : 430 - 431
  • [7] Bispectral index and propofol ± ketamine anesthesia
    Sakai, T
    Mi, WD
    Singh, H
    Kudo, T
    Matsuki, A
    STATE-OF-THE-ART TECHNOLOGY IN ANESTHESIA AND INTENSIVE CARE, 1998, 1168 : 123 - 128
  • [8] Correlation between bispectral index and blood propofol concentration during recovery from anesthesia
    Fujioka, S
    Ohno, T
    Inada, E
    Okada, K
    NEW BALANCED ANESTHESIA, 1998, 1164 : 159 - 160
  • [9] The introduction of bispectral index (BIS) in anesthesia practice
    Galante, Dario
    Melchionda, Matteo
    ANAESTHESIA PAIN & INTENSIVE CARE, 2012, 16 (03) : 230 - 231
  • [10] Correlation between Bispectral Index and EEG
    Pittalis, Angela
    Cavinato, Marianna
    Romano, Sara
    Elefante, Pierandrea
    Tinti, Giulia
    Barbi, Egidio
    Sagredini, Raffaella
    MINERVA ANESTESIOLOGICA, 2021, 87 (09) : 1056 - 1057