Background: Near-infrared spectroscopy of the thenar eminence (NIRSth) is a non-invasive bedside method for assessing tissue oxygenation. The vascular occlusion test (VOT) with a pressure cuff can be used to provide a dynamic assessment of the tissue oxygenation response to ischaemia. VOT has been applied to assess the microcirculation by NIRSth in critically ill patients. The optimal mode of performing such VOT, however, remains controversial. Design, participants and setting: Prospective observational study among a cohort of 11 healthy volunteers in a tertiary intensive care department. Intervention: Measurement of NIRS-derived parameters using 1-, 2- and 3-minute VOTs or VOT to 40% tissue oxygen saturation (StO(2)). Main outcome measure: Changes in StO(2) and tissue haemoglobin index (THI) over time, and relative change from baseline for StO(2) and THI. Results: Mean baseline StO(2) was 80% (SD, 5%) and mean THI was 13.7 (SD, 1.9). The lowest StO(2) at the end of the VOT was 39% (SD, 13%) and 39% (SD, 2%) in the 3-minute and the 40% StO(2) VOTs, respectively. The duration of the 40% StO(2) VOT ranged from 1:35 to 8:21 minutes (median, 3:29 min). There was a difference between the StO(2) curves for the 3-minute and 40% StO(2) VOT (P = 0.005) but not the THI curves. Reported pain score was a median of 3.5 (IQR, 2.5-5.5) and 4 (IQR 2-4) for the 3-minute and 40% StO(2) VOTs, respectively. Conclusions: The 3-minute VOT and the 40% StO(2) appear equivalent. However, the 3-minute VOT carries a degree of decreased patient discomfort and shorter overall duration of execution. Crit Care Resusc 2012; 14: 142-147
引用
收藏
页码:142 / 147
页数:6
相关论文
共 50 条
  • [1] Near-infrared spectroscopy of the thenar eminence to estimate forearm blood flow
    Woinarski, Nicholas C. Z.
    Suzuki, Satoshi
    Lipcsey, Miklos
    Lumsden, Natalie
    Chin-Dusting, Jaye
    Schneider, Antoine G.
    Bailey, Michael
    Bellomo, Rinaldo
    [J]. CRITICAL CARE AND RESUSCITATION, 2013, 15 (04) : 323 - 326
  • [2] Near infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care
    Miklos Lipcsey
    Nicholas CZ Woinarski
    Rinaldo Bellomo
    [J]. Annals of Intensive Care, 2
  • [3] Near infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care
    Lipcsey, Miklos
    Woinarski, Nicholas C. Z.
    Bellomo, Rinaldo
    [J]. ANNALS OF INTENSIVE CARE, 2012, 2
  • [4] The relationship between hyperlactatemia and microcirculation in the thenar eminence as measured using near-infrared spectroscopy in patients with sepsis
    Soga, Taketomo
    Sakatani, Kaoru
    Yagi, Tsukasa
    Kawamorita, Tsuyoshi
    Yoshino, Atsuo
    [J]. EMERGENCY MEDICINE JOURNAL, 2014, 31 (08) : 654 - 658
  • [5] Peripheral vasoconstriction influences thenar oxygen saturation as measured by near-infrared spectroscopy
    Lima, Alexandre
    van Genderen, Michel Egide
    Klijn, Eva
    Bakker, Jan
    van Bommel, Jasper
    [J]. INTENSIVE CARE MEDICINE, 2012, 38 (04) : 606 - 611
  • [6] Peripheral vasoconstriction influences thenar oxygen saturation as measured by near-infrared spectroscopy
    Alexandre Lima
    Michel Egide van Genderen
    Eva Klijn
    Jan Bakker
    Jasper van Bommel
    [J]. Intensive Care Medicine, 2012, 38 : 606 - 611
  • [7] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    [J]. ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [8] USE OF NEAR-INFRARED REFLECTANCE SPECTROSCOPY IN FORAGE TESTING
    JONES, GM
    WADE, NS
    BAKER, JP
    RANCK, EM
    [J]. JOURNAL OF DAIRY SCIENCE, 1987, 70 (05) : 1086 - 1091
  • [9] FORAGE TESTING USING NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    BROWN, WF
    MOORE, JE
    KUNKLE, WE
    CHAMBLISS, CG
    PORTIER, KM
    [J]. JOURNAL OF ANIMAL SCIENCE, 1990, 68 (05) : 1416 - 1427
  • [10] A new near-infrared spectrometer developed for dynamic spectroscopy
    Li Gang
    Liu Yu-liang
    Lin Ling
    Li Xiao-xia
    Wang Yan
    [J]. FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2006, 6047