Effect of pulse delay time on a pre-ablation dual-pulse LIBS plasma

被引:130
|
作者
Stratis, DN [1 ]
Eland, KL [1 ]
Angel, SM [1 ]
机构
[1] Univ S Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
关键词
LIBS; LIPS; dual-pulse LIBS; pre-ablation spark; laser-induced breakdown spectroscopy; laser ablation; plasma temperature; plasma imaging; laser-induced plasma; time-resolved imaging; LCTF;
D O I
10.1366/0003702011953649
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we investigate the effect of dual-pulse timing on material ablation, plasma temperature, and plasma size for pre-ablation spark dual-pulse laser-induced breakdown spectroscopy (LIBS). Although the plasma temperature increases for dual-pulse excitation, the signal enhancement is most easily attributed to increased sample ablation. Plasma images show that the magnitude of the enhancement can be affected by the collection optic and by the collection geometry. Enhancements calculated using the total integrated intensity of the plasma are comparable to those measured using fiber-optic collection.
引用
收藏
页码:1297 / 1303
页数:7
相关论文
共 50 条
  • [1] Dual-pulse LIBS using a pre-ablation spark for enhanced ablation and emission
    Stratis, DN
    Eland, KL
    Angel, SM
    APPLIED SPECTROSCOPY, 2000, 54 (09) : 1270 - 1274
  • [2] Enhancement of aluminum, titanium, and iron in glass using pre-ablation spark dual-pulse LIBS
    Stratis, DN
    Eland, KL
    Angel, SM
    APPLIED SPECTROSCOPY, 2000, 54 (12) : 1719 - 1726
  • [3] Dynamic effects of a pre-ablation spark in the orthogonal dual-pulse laser induced breakdown spectroscopy
    Choi, Sung-Chul
    Oh, Myoung-Kyu
    Lee, Yonghoon
    Nam, Sungmo
    Ko, Do-Kyeong
    Lee, Jongmin
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (05) : 427 - 435
  • [4] Direct Measurements of Sample Heating by a Laser-Induced Air Plasma in Pre-Ablation Spark Dual-Pulse Laser-Induced Breakdown Spectroscopy (LIBS)
    Register, Janna
    Scaffidi, Jonathan
    Angel, S. Michael
    APPLIED SPECTROSCOPY, 2012, 66 (08) : 869 - 874
  • [5] Investigation on Emission Spectra of Reheating and Pre-ablation Dual-Pulse Laser-Induced Breakdown Spectroscopy
    Wang Qi
    Wang Jing-ge
    Liang Yun-xian
    Chen Xing-long
    Wu Bian
    Ni Zhi-bo
    Dong Feng-zhong
    2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2011, 8201
  • [6] Emission enhancement mechanisms in dual-pulse LIBS
    Scaffidi, J
    Angel, SM
    Cremers, DA
    ANALYTICAL CHEMISTRY, 2006, 78 (01) : 24 - 32
  • [7] Optimization of the Time Delay in the UWB Dual-Pulse Receiver
    Wang, Shuyi
    Chen, Yunfei
    Leeson, Mark
    Beaulieu, Norman C.
    2011 IEEE INTERNATIONAL CONFERENCE ON ULTRA-WIDEBAND (ICUWB), 2011, : 445 - 449
  • [8] Optimization of the time delay in the UWB dual-pulse receiver
    School of Engineering, University of Warwick, Coventry, CV4 7AL, United Kingdom
    不详
    Proc. - IEEE Int. Conf. Ultra-Wideband, 2011, (445-449):
  • [9] Pre-ablation laser parameter effects on the spectral enhancement of 1064 nm/1064 nm dual-pulse laser induced breakdown spectroscopy
    Song, Chao
    Gao, Xun
    Shao, Yan
    OPTIK, 2016, 127 (08): : 3979 - 3983
  • [10] Dual-pulse LIBS: why are two lasers better than one?
    Stratis, DN
    Eland, KL
    Angel, SM
    ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES II, 1999, 3853 : 385 - 392