Virus removal of new and aged UF membranes at full-scale in a wastewater reclamation plant

被引:0
|
作者
Reeve, Petra [1 ]
Regel, Rudi [1 ]
Dreyfus, Jennifer [2 ]
Monis, Paul [1 ]
Lau, Melody [1 ]
King, Brendon [1 ]
van den Akker, Ben [1 ]
机构
[1] South Australian Water Corp, Adelaide, SA 5000, Australia
[2] Allwater JV, Adelaide, SA 5000, Australia
关键词
ULTRAFILTRATION MEMBRANES; PHI-X174; BACTERIOPHAGE; MICROBIAL INDICATORS; INTEGRITY; PERFORMANCE; MS2;
D O I
10.1039/c6ew00197a
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ultrafiltration (UF) membrane technology is widely used in water recycling schemes as a physical barrier for the removal of human pathogens. Assessing the consequence of long-term operation (membrane ageing) as well operational extremes on pathogen removal performance is crucial for assessing health risks of human exposure to recycled water. In this study, challenge testing with MS2 bacteriophage (MS2) was undertaken to validate the integrity of full-scale UF membranes used for virus removal in a wastewater recycling plant (WRP). Validation was performed on new (6 months old) and aged (6 years old) membrane units. The impact of a hazardous event-in the form of a short-lived, high turbidity spike-was also assessed since this event affected the hydraulic throughput of exposed membrane units. Validation of the new membranes demonstrated a mean virus log removal value (LRV) of 3.0log(10) (SD = 0.6), with 5th and 95th percentile values ranging between 2.3 and 3.9 log(10) units. Re-validation of the membranes exposed to the hazardous event as well as those that were aged demonstrated that the virus LRV was comparable and had reduced by 1.0log(10) units, measuring 2.0log(10) (SD = 0.2), however the LRV performance was more stable, where the 5th and 95th percentile values ranged between only 1.7 and 2.2 log(10) units. Very little research has previously examined the consequence of membrane ageing or hazardous events on the LRV performance of full-scale UF systems, and thus the findings presented here will facilitate improvements in risk management, in the design of installations and in the operation of UF membrane systems.
引用
收藏
页码:1014 / 1021
页数:8
相关论文
共 50 条
  • [1] Characterization of fouled ultrafiltration membranes from a full-scale wastewater reclamation plant in iron and steel industry
    P.-H. Lin
    Y.-C. Su
    C.-L. Chen
    I.-Y. Tsao
    [J]. International Journal of Environmental Science and Technology, 2023, 20 : 11501 - 11512
  • [2] Characterization of fouled ultrafiltration membranes from a full-scale wastewater reclamation plant in iron and steel industry
    Lin, P. -h.
    Su, Y. -c.
    Chen, C. -l.
    Tsao, I. -y.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2023, 20 (10) : 11501 - 11512
  • [3] Fouling characteristics of reverse osmosis membranes at different positions of a full-scale plant for municipal wastewater reclamation
    Tang, Fang
    Hu, Hong-Ying
    Sun, Li-Juan
    Sun, Ying-Xue
    Shi, Na
    Crittenden, John C.
    [J]. WATER RESEARCH, 2016, 90 : 329 - 336
  • [4] Parameter Identification of an Ultrafiltration Model for Organics Removal in a Full-Scale Wastewater Reclamation Plant with Sparse and Incomplete Monitoring Data
    Sun, Fu
    Zeng, Siyu
    Huang, Yunqing
    He, Miao
    [J]. PLOS ONE, 2016, 11 (08):
  • [5] Effects of chemical cleaning on RO membrane inorganic, organic and microbial foulant removal in a full-scale plant for municipal wastewater reclamation
    Yu, Tong
    Meng, Lu
    Zhao, Qing-Bo
    Shi, Ye
    Hu, Hong-Ying
    Lu, Yun
    [J]. WATER RESEARCH, 2017, 113 : 1 - 10
  • [6] Demonstration of a full-scale plant using an UASB followed by a ceramic MBR for the reclamation of industrial wastewater
    Niwa, Terutake
    Hatamoto, Masashi
    Yamashita, Takuya
    Noguchi, Hiroshi
    Takase, Osamu
    Kekre, Kiran A.
    Ang, Wui Seng
    Tao, Guihe
    Seah, Harry
    Yamaguchi, Takashi
    [J]. BIORESOURCE TECHNOLOGY, 2016, 218 : 1 - 8
  • [7] Optimization of a full-scale Unitank wastewater treatment plant for biological phosphorus removal
    Zhou, Zhen
    Xing, Can
    Wu, Zhichao
    Tong, Fei
    Wang, Junru
    [J]. ENVIRONMENTAL TECHNOLOGY, 2014, 35 (06) : 766 - 772
  • [8] Biological Phosphorus Removal Characteristics in a Full-scale Unitank Wastewater Treatment Plant
    Zhou, Zhen
    Shao, Wenrui
    Xing, Can
    Li, Zheng
    Guan, Pengqiong
    Zhou, Tao
    Wei, Zichao
    [J]. PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 1696 - 1700
  • [9] Fouling of reverse osmosis membrane for municipal wastewater reclamation: Autopsy results from a full-scale plant
    Tang, Fang
    Hu, Hong-Ying
    Sun, Li-Juan
    Wu, Qian-Yuan
    Jiang, Yan-Mei
    Guan, Yun-Tao
    Huang, Jing-Jing
    [J]. DESALINATION, 2014, 349 : 73 - 79
  • [10] Intensified nitrogen removal by endogenous denitrification in a full-scale municipal wastewater treatment plant
    Li, Jia
    Wang, Yayi
    Liu, Jie
    Peng, Yongzhen
    Zhang, Liang
    Lin, Jia