An experimental investigation on frosting characteristics of a microchannel outdoor heat exchanger in an air conditioning heat pump system for electric vehicles

被引:13
|
作者
Li Kang [1 ,2 ]
Luo Shuxian [1 ]
Yu Jun [1 ]
Tang Qitian [3 ]
Su Lin [1 ,2 ]
Fang Yidong [1 ,2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Key Lab Multiphase Flow & Heat Transfer Shanghai, Shanghai, Peoples R China
[3] SAIC Motor Commercial Vehicle Tech Ctr, Shanghai, Peoples R China
关键词
electric vehicles; frosting characteristics; microchannel heat exchanger; system performance; DEFROSTING PERFORMANCE; MASS-TRANSFER; FIN; SURFACES; GROWTH; MECHANISM; BEHAVIOR; MODEL;
D O I
10.1002/er.5519
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To increase the driving range of electric vehicles in cold climate, air conditioning heat pump (ACHP) system is supposed to be the most effective solution. Working near 0 degrees C with high humidity, the microchannel outdoor heat exchanger (OHX) in system would experience badly frosting process, like traditional residential heat pump system. It would lead to a significant reduction of system performance without defrosting in time. In this article, experimental investigation has been implemented on the frosting process of ACHP system of electric vehicles which is with a microchannel OHX. The phenomenon of frosting distribution was observed, the frosted part on surface shows uneven with various flows paths. The typical frosting characteristics of an outdoor microchannel heat exchanger were also obtained. In a self-designed three-heat exchanger ACHP system, the inlet and outlet refrigerant temperature of OHX as well as the outlet air temperature of system decrease with increasing frosting coverage rate. The frosting phenomenon was analyzed with variation of ambient temperature and humidity. System influence by frosting was also studied with under different ambient conditions. When OHX begins to frost, the heating capacity reduction of system under different ambient conditions were both increased but the differences in the coefficient of performance (COP) variations under different ambient conditions were small as frosting progressed.
引用
收藏
页码:7807 / 7819
页数:13
相关论文
共 50 条
  • [1] An experimental investigation on the frosting and defrosting process of an outdoor heat exchanger in an air conditioning heat pump system for electric vehicles
    Li, Kang
    Xia, Dingyu
    Luo, Shuxian
    Zhao, Yugang
    Tu, Ran
    Zhou, Xuejin
    Zhang, Huiqi
    Su, Lin
    [J]. APPLIED THERMAL ENGINEERING, 2022, 201
  • [2] Experimental investigation on frosting performance of a microchannel heat exchanger in heat pump system for electric vehicles
    Liu, Ni
    Li, Dongming
    He, Jianfeng
    Li, Kang
    Tian, Yafen
    Zhang, Hua
    [J]. APPLIED THERMAL ENGINEERING, 2024, 249
  • [3] Investigation on heat transfer characteristics of outside heat exchanger in an air conditioning heat pump system for electric vehicles
    Yu, Jun
    Su, Lin
    Li, Kang
    Liu, Mingkang
    Zhang, Hua
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 170
  • [4] Investigation on reverse cycle defrosting strategy of an outdoor heat exchanger in air conditioning heat pump system for electric vehicles
    Li, Kang
    Xia, Dingyu
    Bao, Jiaqian
    Luo, Shuxian
    Zhang, Hua
    Liu, Ni
    Su, Lin
    Sheng, Lei
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [5] An investigation on dehumidification and heat transfer characteristics of a minichannel heat exchanger for heat pump system of electric vehicles
    Yu, Jun
    Su, Lin
    Li, Kang
    Fang, Yidong
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (13) : 18294 - 18311
  • [6] THE EXPERIMENTAL RESEARCH OF MICROCHANNEL HEAT EXCHANGER ON PACKAGED AIR CONDITIONING SYSTEM
    Wang Ying
    Zhang Ziqi
    Chen Jiang-ping
    Ge Fang-gen
    Wang Feng
    Li Feng
    [J]. 11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 600 - 606
  • [7] Advances on air conditioning and heat pump system in electric vehicles - A review
    Qi, Zhaogang
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 38 : 754 - 764
  • [8] Experimental investigation of the surface temperature and water retention effects on the frosting performance of a compact microchannel heat exchanger for heat pump systems
    Moallem, Ehsan
    Padhmanabhan, Sankar
    Cremaschi, Lorenzo
    Fisher, Daniel E.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (01): : 171 - 186
  • [9] An experimental and theoretical investigation of refrigerant charge on a secondary loop air-conditioning heat pump system in electric vehicles
    Li, Kang
    Xu, Dan
    Lan, Jiao
    Su, Lin
    Fang, Yidong
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (08) : 3381 - 3398
  • [10] Modeling of a Reversible Air Conditioning-Heat Pump System for Electric Vehicles
    Feng, Lili
    Hrnjak, Predrag
    [J]. SAE INTERNATIONAL JOURNAL OF PASSENGER CARS-MECHANICAL SYSTEMS, 2016, 9 (01): : 68 - +