Performance of 2D Synthetic Mammography Versus Digital Mammography in the Detection of Microcalcifications at Screening

被引:20
|
作者
Dodelzon, Katerina [1 ]
Simon, Katherine [1 ]
Dou, Eda [1 ]
Levy, Allison D. [1 ]
Michaels, Aya Y. [1 ]
Askin, Gulce [2 ]
Katzen, Janine T. [1 ]
机构
[1] Weill Cornell Med, Dept Radiol, 525 E 68th St, New York, NY 10065 USA
[2] Weill Cornell Med, Dept Healthcare Policy & Res, Div Biostat & Epidemiol, New York, NY USA
基金
美国国家卫生研究院;
关键词
diagnostic performance; digital breast tomosynthesis; full-field digital mammography; microcalcifications; synthetic mammography; SYNTHESIZED 2-DIMENSIONAL MAMMOGRAPHY; BREAST TOMOSYNTHESIS; DIAGNOSTIC-ACCURACY; IMPLEMENTATION; IMAGES;
D O I
10.2214/AJR.19.21598
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to compare the performance of 2D synthetic mammography (SM) to that of full-field digital mammography (FFDM) in the detection of microcalcifications and to evaluate radiologists' preference between the two imaging modalities for assessing calcifications. MATERIALS AND METHODS. A fully crossed, mode-balanced, paired-case (n = 160), retrospective, multireader (n = 3) performance study was implemented to compare screening mammograms acquired with digital breast tomosynthesis and both FFDM and SM between 2015 and 2017. The study cohort included 70 patients with mammograms recalled for microcalcifications (35 with malignant findings and 35 with benign findings) and was supplemented with 90 patients with mammograms with negative findings. In separate sessions, readers interpreted SM or FFDM images by recording a BI-RADS assessment and the probability of malignancy. In a final session that included 70 mammograms with microcalcifications, readers recorded their subjective assessment of microcalcification conspicuity and diagnostic confidence. RESULTS. There was no difference in diagnostic accuracy as assessed by comparing the likelihood of malignancy based on the AUC of plotted ROCs, with AUCs of 91% (95% CI, 83-97%) and 88% (95% CI, 79-95%) observed for SM and FFDM, respectively (p = 0.392), and with noninferiority of SM compared with FFDM (p = 0.011). No significant difference was observed between SM and FFDM in terms of sensitivity (77% vs 73%, respectively; p = 0.366) or negative predictive value (84% vs 82%, respectively; p = 0.598). The specificity and positive predictive value of SM were lower than those of FFDM (91% vs 98%, respectively [p = 0.034], and 87% vs 96%, respectively [p = 0.034]). All readers found calcifications to be more conspicuous on SM (p < 0.0001); however, no significant difference in subjective diagnostic confidence was seen. CONCLUSION. SM is noninferior to FFDM in the detection of microcalcifications. Despite the increased conspicuity of microcalcifications on SM, the subjective diagnostic confidence in the two modalities is comparable.
引用
收藏
页码:1436 / 1444
页数:9
相关论文
共 50 条
  • [1] Is Synthetic Mammography Comparable to Digital Mammography for Detection of Microcalcifications in Screening?
    Bae, Min Sun
    Moon, Woo Kyung
    [J]. RADIOLOGY, 2018, 289 (03) : 639 - 640
  • [2] Microcalcifications Detected at Screening Mammography: Synthetic Mammography and Digital Breast Tomosynthesis versus Digital Mammography
    Lai, Yi-Chen
    Ray, Kimberly M.
    Lee, Amie Y.
    Hayward, Jessica H.
    Freimanis, Rita I.
    Lobach, Iryna V.
    Joe, Bonnie N.
    [J]. RADIOLOGY, 2018, 289 (03) : 630 - 638
  • [3] Digital Breast Tomosynthesis and Synthetic 2D Mammography versus Digital Mammography: Evaluation in a Population-based Screening Program
    Hofvind, Solveig
    Hovda, Tone
    Holen, Asne S.
    Lee, Christoph I.
    Albertsen, Judy
    Bjorndal, Hilde
    Brandal, Siri H. B.
    Gullien, Randi
    Lomo, Jon
    Park, Daehoon
    Romundstad, Linda
    Suhrke, Pal
    Vigeland, Einar
    Skaane, Per
    [J]. RADIOLOGY, 2018, 287 (03) : 787 - 794
  • [4] Screening Mammography Performance Metrics of 2D Digital Mammography Versus Digital Breast Tomosynthesis in Women With a Personal History of Breast Cancer
    Chikarmane, Sona A.
    Cochon, Laila R.
    Khorasani, Ramin
    Sahu, Sonia
    Giess, Catherine S.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (03) : 587 - 594
  • [5] Detection and characterization of microcalcifications in digital mammography
    Guillemet, H
    Benali, H
    Kahn, E
    DiPaola, R
    [J]. DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 225 - 230
  • [6] Automatic detection of microcalcifications in digital mammography
    Tao, E
    Ornes, C
    Sklansky, J
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 1450 - 1458
  • [7] Synthetic 2D Mammography Versus Standard 2D Digital Mammography: A Diagnostic Test Accuracy Systematic Review and Meta-Analysis
    Abdullah, Peri
    Alabousi, Mostafa
    Ramadan, Sherif
    Zawawi, Ismaiel
    Zawawi, Mayar
    Bhogadi, Yasovineeth
    Freitas, Vivianne
    Patlas, Michael N.
    Alabousi, Abdullah
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (02) : 314 - 324
  • [8] A comparison of the diagnostic performance of 2D synthetic mammography versus digital breast tomosynthesis in 2500 patients
    Holt, S. D.
    Sharaiha, Y. M.
    Moalla, A.
    Williams, H. R.
    Thomas, D.
    Huws, A. M.
    [J]. CANCER RESEARCH, 2016, 76
  • [9] Interval and Consecutive Round Breast Cancer after Digital Breast Tomosynthesis and Synthetic 2D Mammography versus Standard 2D Digital Mammography in BreastScreen Norway
    Hovda, Tone
    Holen, Asne S.
    Lang, Kristina
    Albertsen, Judy Lynn
    Bjorndal, Hilde
    Brandal, Siri H. B.
    Sahlberg, Kristine Kleivi
    Skaane, Per
    Suhrke, Pal
    Hofvind, Solveig
    [J]. RADIOLOGY, 2020, 294 (02) : 256 - 264
  • [10] Accuracy of Synthetic 2D Mammography Compared With Conventional 2D Digital Mammography Obtained With 3D Tomosynthesis
    Simon, Katherine
    Dodelzon, Katerina
    Drotman, Michele
    Levy, Allison
    Arleo, Elizabeth Kagan
    Askin, Gulce
    Katzen, Janine
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (06) : 1406 - 1411