Diagnostic accuracy of 3D-transvaginal ultrasound in detecting uterine cavity abnormalities in infertile patients as compared,with hysteroscopy

被引:20
|
作者
Apirakviriya, Chayanis [1 ]
Rungruxsirivorn, Tassawan [1 ]
Phupong, Vorapong [1 ]
Wisawasukmongchol, Wirach [1 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Obstet & Gynecol, 1873 Rama 4 Rd, Bangkok 10330, Thailand
关键词
Uterine cavity abnormality; 3D transvaginal ultrasound; Hysteroscopy; Infertility; IN-VITRO FERTILIZATION; TRANSVAGINAL ULTRASONOGRAPHY; OUTPATIENT HYSTEROSCOPY; ENDOMETRIAL POLYPS; WOMEN; SONOHYSTEROGRAPHY; SONOGRAPHY; MANAGEMENT; PATHOLOGY; LESIONS;
D O I
10.1016/j.ejogrb.2016.01.023
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess diagnostic accuracy of 3D transvaginal ultrasound (3D-TVS) compared with hysteroscopy in detecting uterine cavity abnormalities in infertile women. Study design: This prospective observational cross-sectional study was conducted during the July 2013 to December 2013 study period. Sixty-nine women with infertility were enrolled. In the mid to late follicular phase of each subject's menstrual cycle, 3D transvaginal ultrasound and hysteroscopy were performed on the same day in each patient. Hysteroscopy is widely considered to be the gold standard method for investigation of the uterine cavity. Uterine cavity characteristics and abnormalities were recorded. Diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios were evaluated. Results: Hysteroscopy was successfully performed in all subjects. Hysteroscopy diagnosed pathological findings in 22 of 69 cases (31.8%). There were 18 endometrial polyps, 3 submucous myomas, and 1 septate uterus. Three-dimensional transvaginal ultrasound in comparison with hysteroscopy had 84.1% diagnostic accuracy, 68.2% sensitivity, 91.5% specificity, 79% positive predictive value, and 86% negative predictive value. The positive and negative likelihood ratios were 8.01 and 0.3, respectively. 3D-TVS successfully detected every case of submucous myoma and uterine anomaly. For detection of endometrial polyps, 3D-TVS had 61.1% sensitivity, 91.5% specificity, and 83.1% diagnostic accuracy. Conclusion: 3D-TVS demonstrated 84.1% diagnostic accuracy for detecting uterine cavity abnormalities in infertile women. A significant percentage of infertile patients had evidence of uterine cavity pathology. Hysteroscopy is, therefore, recommended for accurate detection and diagnosis of uterine cavity lesion. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 20 条
  • [1] Diagnostic Accuracy of Transvaginal Sonography in the Detection of Uterine Abnormalities in Infertile Women
    Niknejadi, Maryam
    Haghighi, Hadieh
    Ahmadi, Firoozeh
    Niknejad, Fatemeh
    Chehrazi, Mohammad
    Vosough, Ahmad
    Moenian, Deena
    IRANIAN JOURNAL OF RADIOLOGY, 2012, 9 (03) : 139 - 144
  • [2] The role of diagnostic hysteroscopy in diagnosis of incomplete uterine septum/significant arcuate uterine anomaly in infertile patients in the era of transvaginal 3D ultrasound scan
    O. Abuzeid
    J. LaChance
    O. Zaghmout
    J. Corrado
    J. Hebert
    M. Ashraf
    M. I. Abuzeid
    Middle East Fertility Society Journal, 25
  • [3] COMPARATIVE STUDY OF HYSTEROSCOPY AND 3D ULTRASOUND FOR DIAGNOSING UTERINE CAVITY ABNORMALITIES
    Grigore, Mihaela
    Pristavu, Anda
    Iordache, F.
    Gafitanu, D.
    Ursulescu, Corina
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2016, 120 (04): : 866 - 873
  • [4] Diagnostic accuracy of transvaginal ultrasonography and hysterosalpingography in the detection of uterine cavity pathologies among infertile women
    Okonkwo, Ifeanyi O.
    Eleje, George U.
    Obiechina, Nworah J.
    Ugboaja, Joseph O.
    Okafor, Chisolum O.
    Mbachu, Ikechukwu I.
    Obiagwu, Hillary, I
    Okwuosa, Ayodele O.
    Onwusulu, Daniel N.
    Okeke, Chukwunwendu F.
    Ofojebe, Chukwuemeka J.
    Okafor, Chidinma C.
    Ogabido, Chukwudi A.
    Olisa, Chinedu L.
    Okafor, Chigozie G.
    ACTA RADIOLOGICA OPEN, 2024, 13 (05)
  • [5] Diagnostic accuracy of hysteroscopy, ultrasound and magnetic resonance imaging in detecting congenital uterine anomalies
    Alonso, Luis
    Carugno, Jose
    Nappi, Luigi
    MINERVA OBSTETRICS AND GYNECOLOGY, 2022, 74 (01) : 12 - 23
  • [6] The role of diagnostic hysteroscopy in diagnosis of incomplete uterine septum/significant arcuate uterine anomaly in infertile patients in the era of transvaginal 3D ultrasound scan (vol 25, 1 2020)
    Abuzeid, O.
    LaChance, J.
    Zaghmout, O.
    Corrado, J.
    Hebert, J.
    Ashraf, M.
    Abuzeid, M. I.
    MIDDLE EAST FERTILITY SOCIETY JOURNAL, 2020, 25 (01)
  • [7] Diagnostic accuracy at sonohysterography, transvaginal sonography, and hysterosalpingography in patients with uterine cavity diseases
    Soares, SR
    dos Reis, MMBB
    Camargos, AF
    FERTILITY AND STERILITY, 2000, 73 (02) : 406 - 411
  • [8] Evaluation of abnormal uterine bleeding by transvaginal 3-D hysterosonography and diagnostic hysteroscopy
    Makris, N.
    Skartados, N.
    Kalmantis, K.
    Mantzaris, G.
    Papadimitriou, A.
    Antsaklis, A.
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2007, 28 (01) : 39 - 42
  • [9] The role of diagnostic hysteroscopy in diagnosis of incomplete uterine septum in patients with recurrent pregnancy loss in the era of transvaginal 3D ultrasound scan
    Abuzeid, O.
    LaChance, J.
    Hebert, J.
    Abuzeid, M., I
    Welch, R.
    GYNECOLOGICAL SURGERY, 2019, 16 (01)
  • [10] Comparison of two-dimensional (2d) transvaginal ultrasound, three-dimensional (3d) ultrasound and hysteroscopy to diagnose in patients with abnormal uterine bleeding
    Kutlucan, H.
    Isik, G.
    Akdulum, M. Cevher
    Demirdag, E.
    Erdem, O.
    Bozkurt, N.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 270 : E29 - E29