GPU-based Monte Carlo ray tracing simulation considering refraction for central receiver system

被引:6
|
作者
Lin, Xiaoxia [1 ]
He, Caitou [2 ]
Huang, Wenjun [3 ]
Zhao, Yuhong [3 ]
Feng, Jieqing [1 ]
机构
[1] Zhejiang Univ, State Key Lab CAD &CG, Hangzhou 310058, Peoples R China
[2] Wenzhou Univ, Coll Comp Sci & Artificial Intelligence, Wenzhou 325035, Peoples R China
[3] Zhejiang Univ, Inst Ind Proc Control, Coll Control Sci & Engn, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Central receiver system; Monte Carlo ray-tracing; Flux density distribution simulation; Refraction; GPU; FLUX-DENSITY; SOLAR; MODEL; DISTRIBUTIONS; SUNSHAPE;
D O I
10.1016/j.renene.2022.04.151
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The heliostat in the central receiver system usually adopts silvered-glass reflectors, where a glass layer covers a specular reflection layer. Previous flux density distribution simulation methods ignored the refraction effects caused by the glass layer. This paper proposes a more accurate Monte Carlo ray-tracing simulation method considering refraction and total internal reflection (TIR) effects caused by the ray transmission in the glass layer. The proposed simulation method is fully designed and implemented on a graphics processing unit (GPU), which enables the algorithm performance to remain effective even when the simulation is more consistent with the real situation. Experiments and simulations reveal that refraction has non-negligible effects on the simulation results. Compared with the classical Monte Carlo ray-tracing simulation method that only considers the ray's reflection, refraction reduces the maximum radiative flux and total energy by up to 80% and 50%, respectively. Refraction also causes the flux spot reflected on the receiver panel to spread greatly. In several extreme cases, the ray is trapped in the glass due to TIR.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:367 / 382
页数:16
相关论文
共 50 条
  • [1] Simulation of Spectral Reflectances in Human Skin Tissue Using Ray Tracing and GPU-Based Monte Carlo Method
    Funamizu, Hideki
    Maeda, Takaaki
    Sasaki, Shoko
    Nishidate, Izumi
    Aizu, Yoshihisa
    OPTICAL REVIEW, 2014, 21 (03) : 359 - 363
  • [2] Simulation of spectral reflectances in human skin tissue using ray tracing and GPU-based Monte Carlo method
    Hideki Funamizu
    Takaaki Maeda
    Shoko Sasaki
    Izumi Nishidate
    Yoshihisa Aizu
    Optical Review, 2014, 21 : 359 - 363
  • [3] GPU-Based Monte Carlo Simulation for the Gibbs Ensemble
    Hailat, Eyad
    Rushaidat, Kamel
    Schwiebert, Loren
    Mick, Jason R.
    Potoff, Jeffery J.
    HIGH PERFORMANCE COMPUTING SYMPOSIUM 2013 (HPC 2013) - 2013 SPRING SIMULATION MULTI-CONFERENCE (SPRINGSIM'13), 2013, 45 (06): : 75 - 82
  • [4] GPU-BASED ACCELERATION FOR MONTE CARLO RAY-TRACING OF COMPLEX 3D SCENE
    Li, Yuguang
    Dai, Xu
    Zhao, Feng
    Shang, Hong
    2012 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2012, : 4240 - 4243
  • [5] GPU-based nonlinear ray tracing
    Weiskopf, D
    Schafhitzel, T
    Ertl, T
    COMPUTER GRAPHICS FORUM, 2004, 23 (03) : 625 - 633
  • [6] Expanding a GPU-Based Monte Carlo Simulation Package for Proton Therapy
    Zhong, Y.
    Cheng, X.
    Hu, K.
    Xiong, Z.
    Shao, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E167 - E168
  • [7] GPU-based fast Monte Carlo simulation for radiotherapy dose calculation
    Jia, Xun
    Gu, Xuejun
    Graves, Yan Jiang
    Folkerts, Michael
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22): : 7017 - 7031
  • [8] gPET: a GPU-based, accurate and efficient Monte Carlo simulation tool for PET
    Lai, Youfang
    Zhong, Yuncheng
    Chalise, Ananta
    Shao, Yiping
    Jin, Mingwu
    Jia, Xun
    Chi, Yujie
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (24):
  • [9] A dynamic accuracy estimation for GPU-based monte carlo simulation in tissue optics
    Cai F.
    Lu W.
    Lu, Wen (wen_lu@yeah.net), 2017, Optical Society of Korea (01) : 551 - 555
  • [10] A GPU-based direct Monte Carlo simulation of time dependence in nuclear reactors
    Molnar, Balazs
    Tolnai, Gabor
    Legrady, David