Novel real-time method using the stopped-flow for evaluating bisphenol A degradation kinetics by molecular ozone and radical mechanisms

被引:1
|
作者
Flores-Payan, V. [1 ]
Leon-Becerril, E. [1 ]
Lopez-Lopez, A. [1 ]
Vallejo-Rodriguez, R. [1 ]
机构
[1] Ctr Invest & Asistencia Tecnol & Diseno Estado Ja, Environm Technol Dept, Av Normalistas 800, Guadalajara 44270, Jalisco, Mexico
关键词
Bisphenol A; HO-probe; Ozone; pCBA; Second-order rate constants; Stopped-flow; RATE CONSTANTS; INORGANIC-COMPOUNDS; OZONATION; WATER; OXIDATION; PHARMACEUTICALS; STEROIDS;
D O I
10.1080/00986445.2017.1344652
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A novel real-time method was developed to evaluate the bisphenol A degradation kinetics by molecular ozone and radical pathway using the stopped-flow technique. The second-order kinetics was determined under pseudo-first-order conditions for the molecular pathway by the absolute rate constant method and for the radical pathway by the R-ct concept involving the hydroxyl radical and ozone ratio. Bisphenol A degradation by ozone was performed and evaluated at a pH ranging from 2 to 10. At pH<4 (molecular pathway), the second-order rate constant value was 1.12x10(4)M(-1)s(-1) and for the radical pathway at pH>10, the constant was 3.43x10(9)M(-1)s(-1). To validate the method, ciprofloxacin degradation kinetics was determined at pH 8 by radical pathway, in 4.55x10(9)M(-1)s(-1). The method permits the determination of kinetic parameters for the design of chemical reactors; avoiding the generation of undesirable reactions and by-products in the degradation of emerging compounds.
引用
收藏
页码:1113 / 1121
页数:9
相关论文
共 50 条
  • [1] Quantitative and convenient real-time reaction monitoring using stopped-flow benchtop NMR
    Maschmeyer, Tristan
    Yunker, Lars P. E.
    Hein, Jason E.
    REACTION CHEMISTRY & ENGINEERING, 2022, 7 (05): : 1061 - 1072
  • [2] REAL-TIME KINETICS OF GENE-TRANSCRIPTION - MULTICOLOR TIME-RESOLVED AND STOPPED-FLOW FLUORESCENCE STUDIES
    BEECHEM, JM
    BIOPHYSICAL JOURNAL, 1994, 66 (02) : A233 - A233
  • [3] Real-time assay of immobilized tannase with a stopped-flow conductometric device
    Chang, Fu-Shiang
    Chen, Po-Chung
    Chen, Richie L. C.
    Lu, Fu-Ming
    Cheng, Tzong-Jih
    BIOELECTROCHEMISTRY, 2006, 69 (01) : 113 - 116
  • [4] An intermediate state of the triphenylamine cation radical revealed using an electron-transfer stopped-flow method
    Oyama, M
    Higuchi, T
    Okazaki, S
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2002, 5 (02) : E1 - E3
  • [5] DETERMINATION OF LOW CONCENTRATIONS OF PROTEIN BY THE BIURET METHOD USING THE STOPPED-FLOW TIME DIFFERENCE ANALYSIS TECHNIQUE
    KANAYA, K
    HIROMI, K
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1987, 51 (07): : 1885 - 1892
  • [6] Millisecond Time-Scale Folding and Unfolding of DNA Hairpins Using Rapid-Mixing Stopped-Flow Kinetics
    Nayak, Rajesh K.
    Peersen, Olve B.
    Hall, Kathleen B.
    Van Orden, Alan
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (05) : 2453 - 2456
  • [7] Real-time refolding studies of 6-F-19-tryptophan labeled Escherichia coli dihydrofolate reductase using stopped-flow NMR spectroscopy
    Hoeltzli, SD
    Frieden, C
    BIOCHEMISTRY, 1996, 35 (51) : 16843 - 16851
  • [8] Kinetics of CO2 Absorption into a Novel 1-Diethylamino-2-propanol Solvent Using Stopped-Flow Technique
    Liu, Helei
    Liang, Zhiwu
    Sema, Teerawat
    Rongwong, Wichitpan
    Li, Chen
    Na, Yanqing
    Idem, Raphael
    Tontiwachwuthikul, Paitoon
    Idem, Raphael
    Tontiwachwuthikul, Paitoon
    AICHE JOURNAL, 2014, 60 (10) : 3502 - 3510
  • [9] Sensitive and Real-Time Method for Evaluating Corneal Barrier Considering Tear Flow
    Nakamura, Tadahiro
    Teshima, Mugen
    Kitahara, Takashi
    Sasaki, Hitoshi
    Uematsu, Masafumi
    Kitaoka, Takashi
    Nakashima, Mikiro
    Nishida, Koyo
    Nakamura, Junzo
    Higuchi, Shun
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2010, 33 (01) : 107 - 110
  • [10] The adsorption-desorption kinetics of dodecyl sulfate ions to and from polystyrene latex using the electric conductivity stopped-flow method
    Miyamoto, S
    NIPPON KAGAKU KAISHI, 1998, (03) : 167 - 173