Design and development of a suitable adsorbent to capture theophylline for non-invasive therapeutic drug monitoring with exhaled breath

被引:3
|
作者
Yamamoto, A. [1 ]
Hioki, S. [1 ]
Tanada, C. [1 ]
Miwa, T.
Inoue, Y. [1 ]
Yamamoto, R. [1 ]
Matsushima, M. [2 ]
Kawabe, T. [2 ]
机构
[1] Chubu Univ, Coll Biosci & Biotechnol, Kasugai, Aichi 4878501, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Pathophysiol Lab Sci, Higashi Ku, Nagoya, Aichi 4618673, Japan
基金
日本学术振兴会;
关键词
FEASIBILITY; BIOMARKERS; PARTICLES; PROPOFOL; URINE; ABUSE; RAT; AIR;
D O I
10.1039/c4ay02243b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The possibility of using exhaled breath as a substitute for blood/plasma in areas of therapeutic drug monitoring was investigated. Theophylline was used as a model chemical of non-volatile drugs and the adsorbents suitable for drug capture from exhaled breath were studied. Two macro-porous adsorbents with different monomer compositions were prepared by suspension copolymerization. The capture properties of the synthesized adsorbents and two conventional gas adsorbents packed in a cartridge were evaluated by both aerosol generation and rat expiration. The efficiency of drug capture did not improve by decreasing the pore size and by increasing the specific surface area. A hydrophilic region was found to be necessary for holding the aerosol particles on the adsorbent surface, but a hydrophobic region is also necessary for the adsorption of theophylline. The materials were applied to the intravenous bolus experiment of rats. The amount of theophylline collected from exhaled breath was in the range of 0-0.02 ng min(-1), and it varied similarly to the concentration in blood, which was in the range of 0-37 mu g mL(-1).
引用
收藏
页码:423 / 427
页数:5
相关论文
共 50 条
  • [1] Non-invasive exhaled breath diagnostic and monitoring technologies
    Ma, Pengze
    Li, Jiaqi
    Chen, Yongxing
    Zhou Montano, Baiyang Antonio
    Luo, Huijian
    Zhang, Di
    Zheng, Huadan
    Liu, Yihua
    Lin, Haoyang
    Zhu, Wenguo
    Zhang, Guanfeng
    Mao, Hua
    Yu, Jianhui
    Chen, Zhe
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1475 - 1488
  • [2] Therapeutic drug monitoring of antibiotics in exhaled breath
    Drager, S.
    Yin, Z.
    Muller, S. L.
    Richard, M.
    Osthoff, M.
    Sinues, P.
    SWISS MEDICAL WEEKLY, 2024, 154 : 75S - 76S
  • [3] A Review of Biosensors for Non-Invasive Diabetes Monitoring and Screening in Human Exhaled Breath
    Usman, Fahad
    Dennis, J. O.
    Ahmed, A. Y.
    Meriaudeau, Fabrice
    Ayodele, O. B.
    Rabih, Almur A. S.
    IEEE ACCESS, 2019, 7 : 5963 - 5974
  • [4] Non-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol)
    Karyakin, Arkady A.
    Nikulina, Svetlana V.
    Vokhmyanina, Darya V.
    Karyakina, Elena E.
    Anaev, Eldar K. H.
    Chuchalin, Alexander G.
    ELECTROCHEMISTRY COMMUNICATIONS, 2017, 83 : 81 - 84
  • [5] Non-invasive diagnosis and monitoring of Cystic Fibrosis by mass spectrometry of the exhaled breath
    Gramacho, S.
    Pineiro, M.
    Pais, A. A. C. C.
    d'A Rocha Gonsalves, A. M.
    Gamboa, F.
    Robalo Cordeiro, C.
    TECHNOLOGY AND MEDICAL SCIENCES - TMSI 2010, 2011, : 209 - 214
  • [6] Development of a non-invasive exhaled breath test for the diagnosis of head and neck cancer
    Dharmawardana, Nuwan
    Goddard, Thomas
    Woods, Charmaine
    Watson, David, I
    Ooi, Eng H.
    Yazbeck, Roger
    BRITISH JOURNAL OF CANCER, 2020, 123 (12) : 1775 - 1781
  • [7] Development of a non-invasive exhaled breath test for the diagnosis of head and neck cancer
    Nuwan Dharmawardana
    Thomas Goddard
    Charmaine Woods
    David I. Watson
    Eng H. Ooi
    Roger Yazbeck
    British Journal of Cancer, 2020, 123 : 1775 - 1781
  • [8] Non-invasive biomarker sampling and analysis of the exhaled breath proteome
    Bloemen, Karolien
    Hooyberghs, Jef
    Desager, Kristine
    Witters, Erwin
    Schoeters, Greet
    PROTEOMICS CLINICAL APPLICATIONS, 2009, 3 (04) : 498 - 504
  • [9] Non-Invasive Measurement of Plasma Triglycerides from Exhaled Breath
    Minh, Timothy D. C.
    Oliver, Stacy R.
    Blake, Donald R.
    Carson, Matthew K.
    Meinardi, Simone
    Galassetti, Pietro R.
    DIABETES, 2010, 59 : A291 - A292
  • [10] Porous materials applied to biomarker sensing in exhaled breath for monitoring and detecting non-invasive pathologies
    Andre, Laurie
    Desbois, Nicolas
    Gros, Claude P.
    Brandes, Stephane
    DALTON TRANSACTIONS, 2020, 49 (43) : 15161 - 15170