Automated cerebrospinal fluid cytology

被引:0
|
作者
Heller, Tanja [2 ]
Nagel, Ingelore [1 ]
Ehrlich, Bettina [2 ]
Baehr, Mathias [1 ]
Strik, Herwig [1 ]
机构
[1] Univ Gottingen, Dept Neurol, D-37075 Gottingen, Germany
[2] Univ Gottingen, Dept Clin Chem, D-37075 Gottingen, Germany
来源
关键词
Abbott CELL-DYN Sapphire; cell count; cell differentiation; cytology; cerebrospinal fluid; cytometer;
D O I
暂无
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
OBJECTIVE: To evaluate the Abbott CELL-DYN Sapphire cytometer for cerebrospinal fluid (CSF) cell count and differentiation. METHODS: One hundred three analyses of CSF cells by the CELL-DYN Sapphire were compared with routine cell count and microscopic differentiation and correlation coefficients calculated. RESULTS: The total cell count of both methods correlated well. The detection of erythrocytes was good (0.898), and a higher content of erythrocytes > 100/mu L had little effect on total leukocyte count. The correlation between both methods was best with higher leukocyte counts > 25/mu L (r = 0.987), whereas at cell counts < 25/mu L, the correlation was considerably less precise (r = 0.613). For the differentiation of cells, lymphocytes and neutrophils showed moderate correlation. The results for monocytes and eosinophils did not correlate. CONCLUSION: The results for the total cell count in this study are comparable with those achieved with the Bayer Advia 120. While the Abbott CELL-DYN Sapphire yielded slightly better results for erythrocytes and total cell count with a higher erythrocyte content, the Advia 120 achieved slightly better results of lymphocyte and neutrophil count in a previous study.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [1] Automated cerebrospinal fluid cytology - Limitations and reasonable applications
    Strik, H
    Luthe, H
    Nagel, I
    Ehrlich, B
    Bahr, M
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 2005, 27 (03): : 167 - 173
  • [3] The cytology of the cerebrospinal fluid
    Rotstadt, J
    ZEITSCHRIFT FUR DIE GESAMTE NEUROLOGIE UND PSYCHIATRIE, 1916, 31 : 228 - 274
  • [4] CYTOLOGY OF CEREBROSPINAL-FLUID
    SHAH, NT
    AMERICAN JOURNAL OF MEDICAL TECHNOLOGY, 1982, 48 (10): : 829 - 831
  • [5] CEREBROSPINAL-FLUID CYTOLOGY
    ZELE, J
    ZDRAVSTVENI VESTNIK, 1977, 46 (03): : 195 - 199
  • [6] Examples of cerebrospinal fluid cytology
    Prater, R
    Bender, H
    Shell, L
    PROGRESS IN VETERINARY NEUROLOGY, 1996, 7 (04): : 133 - &
  • [7] Pitfalls in cerebrospinal fluid cytology
    Ranchère-Vince, D
    Vielh, P
    ANNALES DE PATHOLOGIE, 1999, 19 (05) : 450 - 456
  • [8] CYTOCENTRIFUGE AND CEREBROSPINAL-FLUID CYTOLOGY
    HANSEN, HH
    BENDER, RA
    SHELTON, BJ
    ACTA CYTOLOGICA, 1974, 18 (03) : 259 - 262
  • [9] CYTOLOGY OF EQUINE CEREBROSPINAL-FLUID
    BEECH, J
    VETERINARY PATHOLOGY, 1983, 20 (05) : 553 - 562
  • [10] VALUE OF CEREBROSPINAL-FLUID CYTOLOGY
    JAMESON, B
    ACTA CYTOLOGICA, 1972, 16 (04) : 388 - &