Surface Charge Density Determination of Single Conical Nanopores Based on Normalized Ion Current Rectification

被引:84
|
作者
Liu, Juan [1 ]
Kvetny, Maksim [1 ]
Feng, Jingyu [1 ]
Wang, Dengchao [1 ]
Wu, Baohua [1 ]
Brown, Warren [1 ]
Wang, Gangli [1 ]
机构
[1] Georgia State Univ, Dept Chem, Atlanta, GA 30302 USA
关键词
SOLID-STATE NANOPORES; TRANSPORT-PROPERTIES; GLASS; ELECTRODES; MEMBRANES; ELECTROCHEMISTRY; MOLECULES; PROTEIN; DIODES;
D O I
10.1021/la203106w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Current rectification is well known in ion transport through nanoscale pores and channel devices. The measured current is affected by both the geometry and fixed interfacial charges of the nanodevices. In this article, an interesting trend is observed in steady-state current potential measurements using single conical nanopores. A threshold low-conductivity state is observed upon the dilution of electrolyte concentration. Correspondingly, the normalized current at positive bias potentials drastically increases and contributes to different degrees of rectification. This novel trend at opposite bias polarities is employed to differentiate the ion flux affected by the fixed charges at the substrate-solution interface (surface effect), with respect to the constant asymmetric geometry (volume effect). The surface charge density (SCD) of individual naanopores, an important physical parameter that is challenging to measure experimentally and is known to vary from one nanopore to another, is directly quantified by solving Poisson and Nernst-Planck equations in the simulation of the experimental results. The flux distribution inside the nanopore and the SCD of individual nanopores are reported. The respective diffusion and migration translocations are found to vary at different positions inside the nanopore. This knowledge is believed to be important for resistive pulse sensing applications because the detection signal is determined by the perturbation of the ion current by the analytes.
引用
收藏
页码:1588 / 1595
页数:8
相关论文
共 50 条
  • [1] Ion current rectification coupled with asymmetric temperature and surface charge in ultrashort conical nanopores
    Li, Zhenquan
    Qiao, Nan
    Zhang, Zhe
    Lu, Wei
    Li, Changzheng
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 205
  • [2] Ion current rectification influenced by length and location of surface charge in fluidic unipolar conical nanopores
    Singh, Kunwar Pal
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 493 - 500
  • [3] Influences of Cone Angle and Surface Charge Density on the Ion Current Rectification Behavior of a Conical Nanopore
    Tseng, Shiojenn
    Lin, Sheng-Chang
    Lin, Chih-Yuan
    Hsu, Jyh-Ping
    JOURNAL OF PHYSICAL CHEMISTRY C, 2016, 120 (44): : 25620 - 25627
  • [4] Ion current rectification and rectification inversion in conical nanopores: a perm-selective view
    Momotenko, Dmitry
    Cortes-Salazar, Fernando
    Josserand, Jacques
    Liu, Shujuan
    Shao, Yuanhua
    Girault, Hubert H.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2011, 13 (12) : 5430 - 5440
  • [5] Aprotic Solvent Accumulation Amplifies Ion Current Rectification in Conical Nanopores
    Farrell, Emer B.
    Duleba, Dominik
    Johnson, Robert P.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2022, 126 (30): : 5689 - 5694
  • [6] Scan-Rate-Dependent Ion Current Rectification and Rectification Inversion in Charged Conical Nanopores
    Momotenko, Dmitry
    Girault, Hubert H.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (37) : 14496 - 14499
  • [7] Concentration-Gradient-Dependent Ion Current Rectification in Charged Conical Nanopores
    Cao, Liuxuan
    Guo, Wei
    Wang, Yugang
    Jiang, Lei
    LANGMUIR, 2012, 28 (04) : 2194 - 2199
  • [8] Modulation of Ionic Current Rectification in Ultrashort Conical Nanopores
    Ma, Long
    Li, Zhongwu
    Yuan, Zhishan
    Huang, Chuanzhen
    Siwy, Zuzanna S.
    Qiu, Yinghua
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 16188 - 16196
  • [9] Charge Induced Rectification in Single Nanopores
    Yang, Crystal
    Menestrina, Justin
    Hinkle, Preston
    Vlassiouk, Ivan
    Siwy, Zuzanna
    BIOPHYSICAL JOURNAL, 2016, 110 (03) : 651A - 651A
  • [10] Pressure-Dependent Ion Current Rectification in Conical-Shaped Glass Nanopores
    Lan, Wen-Jie
    Holden, Deric A.
    White, Henry S.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (34) : 13300 - 13303