Intraoperative loose flexion gap may restrict postoperative knee flexion after J-curve design posterior-stabilized total knee arthroplasty

被引:4
|
作者
Tsukada, Sachiyuki [1 ]
Kurosaka, Kenji [1 ]
Nishino, Masahiro [1 ]
Ogawa, Hiroyuki [1 ]
Hirasawa, Naoyuki [1 ]
机构
[1] Hokusuikai Kinen Hosp, Dept Orthopaed Surg, 3-2-1 Higashihara, Mito, Ibaraki 3100035, Japan
关键词
Knee; Primary arthroplasty; Soft tissue balance; Range of motion; Tensor device; JOINT GAP; RESECTION; ANGLE;
D O I
10.1007/s00590-019-02538-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionAlthough soft tissue tension during total knee arthroplasty (TKA) has been targeted to achieve equal flexion and extension gaps, such a perfect gap is not always obtained. This study was performed to investigate the impact of difference between flexion and extension gaps on postoperative knee flexion angle.Materials and methodsWe reviewed 107 consecutive TKAs using a J-curve design posterior-stabilized prosthesis. Soft tissue tension was measured intraoperatively using an offset-type tensor under 30 lb force of joint distraction with the patella reduced. All TKAs were performed in a uniform manner including the subvastus approach and without use of a pneumatic tourniquet. We assessed the association between knee flexion angle 1 year after TKA and the difference between flexion and extension gaps using Pearson's product-moment correlation and multiple regression analysis with age, sex, body mass index, diagnosis, history of diabetes mellitus, preoperative flexion angle, and gap difference as explanatory variables.ResultsThe difference between flexion and extension gaps showed a slight negative correlation with postoperative knee flexion angle in univariate analysis (r=-0.20, 95% CI, -0.38 to -0.01, p=0.04). Multiple regression analysis showed that the gap difference was an independent factor associated with postoperative knee flexion angle (beta=-0.89, 95% CI, -1.60 to -0.18, p=0.01).ConclusionsThe difference between flexion and extension gaps was negatively correlated with postoperative knee flexion angle. Looser flexion gap compared with extension gap should be avoided in J-curve design posterior-stabilized TKA.
引用
收藏
页码:147 / 151
页数:5
相关论文
共 50 条
  • [1] Intraoperative loose flexion gap may restrict postoperative knee flexion after J-curve design posterior-stabilized total knee arthroplasty
    Sachiyuki Tsukada
    Kenji Kurosaka
    Masahiro Nishino
    Hiroyuki Ogawa
    Naoyuki Hirasawa
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 147 - 151
  • [2] The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty
    Xiaojun Shi
    Bin Shen
    Pengde Kang
    Jing Yang
    Zongke Zhou
    Fuxing Pei
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2696 - 2703
  • [3] The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty
    Shi, Xiaojun
    Shen, Bin
    Kang, Pengde
    Yang, Jing
    Zhou, Zongke
    Pei, Fuxing
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (12) : 2696 - 2703
  • [4] Medial knee stability at flexion increases tibial internal rotation and knee flexion angle after posterior-stabilized total knee arthroplasty
    Kamenaga, Tomoyuki
    Takayama, Koji
    Ishida, Kazunari
    Muratsu, Hirotsugu
    Hayashi, Shinya
    Hashimoto, Shingo
    Kuroda, Yuichi
    Tsubosaka, Masanori
    Takashima, Yoshinori
    Matsushita, Takehiko
    Niikura, Takahiro
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    [J]. CLINICAL BIOMECHANICS, 2019, 68 : 16 - 22
  • [5] Evaluation of the flexion gap with a distal femoral trial component in posterior-stabilized total knee arthroplasty
    Kamei, Goki
    Ishibashi, Shigeki
    Yoshioka, Koki
    Sakurai, Satoru
    Inoue, Hiroyuki
    Mochizuki, Yu
    Ishikawa, Masakazu
    Adachi, Nobuo
    [J]. KNEE SURGERY & RELATED RESEARCH, 2022, 34 (01)
  • [6] Evaluation of the flexion gap with a distal femoral trial component in posterior-stabilized total knee arthroplasty
    Goki Kamei
    Shigeki Ishibashi
    Koki Yoshioka
    Satoru Sakurai
    Hiroyuki Inoue
    Yu Mochizuki
    Masakazu Ishikawa
    Nobuo Adachi
    [J]. Knee Surgery & Related Research, 34
  • [7] Efficacy of posterior capsular release for flexion contracture in posterior-stabilized total knee arthroplasty
    Tomofumi Kinoshita
    Kazunori Hino
    Tatsuhiko Kutsuna
    Kunihiko Watamori
    Takashi Tsuda
    Hiromasa Miura
    [J]. Journal of Experimental Orthopaedics, 8
  • [8] Efficacy of posterior capsular release for flexion contracture in posterior-stabilized total knee arthroplasty
    Kinoshita, Tomofumi
    Hino, Kazunori
    Kutsuna, Tatsuhiko
    Watamori, Kunihiko
    Tsuda, Takashi
    Miura, Hiromasa
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2021, 8 (01)
  • [9] Influence of intra-operative parameters on postoperative early recovery of active knee flexion in posterior-stabilized total knee arthroplasty
    Nagai, Kanto
    Muratsu, Hirotsugu
    Matsumoto, Tomoyuki
    Maruo, Akihiro
    Miya, Hidetoshi
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (11) : 2153 - 2157
  • [10] Influence of intra-operative parameters on postoperative early recovery of active knee flexion in posterior-stabilized total knee arthroplasty
    Kanto Nagai
    Hirotsugu Muratsu
    Tomoyuki Matsumoto
    Akihiro Maruo
    Hidetoshi Miya
    Ryosuke Kuroda
    Masahiro Kurosaka
    [J]. International Orthopaedics, 2013, 37 : 2153 - 2157