Long-path measurement of atmospheric NO2 with an obstruction flashlight and a charge-coupled-device spectrometer

被引:22
|
作者
Yoshii, Y [1 ]
Kuze, H [1 ]
Takeuchi, N [1 ]
机构
[1] Chiba Univ, Ctr Environm Remote Sensing, Inage Ku, Chiba 2638522, Japan
关键词
D O I
10.1364/AO.42.004362
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel method of differential optical absorption spectroscopy (DOAS) is proposed and demonstrated to monitor the concentration of atmospheric pollutant gas. In contrast to conventional DOAS measurements with continuous light sources, the present method relies on white flashlights such as aviation obstruction lights that are generally installed on tall constructions. A simple detection system is devised by means of a telescope and a compact CCD spectrometer. A path length of 5.5 km allows us to measure atmospheric NO2 concentration with a detection limit of approximately 1 part per billion. We also discuss the possibility of deriving the aerosol optical thickness through the horizontal atmosphere from this pulsed DOAS measurement. (C) 2003 Optical Society of America.
引用
收藏
页码:4362 / 4368
页数:7
相关论文
共 47 条
  • [1] Measurement of regional distribution of atmospheric NO2 and aerosol particles with flashlight long-path optical monitoring
    Fuqi, S
    Kuze, H
    Yoshii, Y
    Nemoto, M
    Takeuchi, N
    Kimura, T
    Umekawa, T
    Yoshida, T
    Hioki, T
    Tsutsui, T
    Kawasaki, M
    ATMOSPHERIC ENVIRONMENT, 2005, 39 (27) : 4959 - 4968
  • [2] MEASUREMENT OF CHANNEL POTENTIAL IN CHARGE-COUPLED-DEVICE STRUCTURES
    TAYLOR, GW
    TASCH, AF
    SOLID-STATE ELECTRONICS, 1977, 20 (05) : 473 - 474
  • [3] INTENSIFIED CHARGE-COUPLED-DEVICE CAMERAS FOR A SPATIALLY RESOLVING EXTREME ULTRAVIOLET SPECTROMETER
    CONTENT, D
    PERRY, M
    WROBLEWSKI, D
    MOOS, HW
    OPTICAL ENGINEERING, 1987, 26 (08) : 806 - 812
  • [4] Long-path supercontinuum absorption spectroscopy for measurement of atmospheric constituents
    Brown, David M.
    Shi, Kebin
    Liu, Zhiwen
    Philbrick, C. Russell
    OPTICS EXPRESS, 2008, 16 (12) : 8457 - 8471
  • [5] LONG-PATH FTIR MEASUREMENT OF ATMOSPHERIC TRACE GAS CONCENTRATIONS
    GOSZ, JR
    DAHM, CN
    RISSER, PG
    ECOLOGY, 1988, 69 (05) : 1326 - 1330
  • [6] LONG SLIT CHARGE-COUPLED-DEVICE OBSERVATIONS OF ACTIVE AND NORMAL GALAXIES
    CARONE, TE
    MORRIS, SL
    LEACH, RW
    OPTICAL ENGINEERING, 1987, 26 (10) : 1043 - 1047
  • [7] HIGH-PRECISION MEASUREMENT OF PIXEL POSITIONS IN A CHARGE-COUPLED-DEVICE
    SHAKLAN, S
    SHARMAN, MC
    PRAVDO, SH
    APPLIED OPTICS, 1995, 34 (29): : 6672 - 6681
  • [8] Measurement of atmospheric oxygen using long-path supercontinuum absorption spectroscopy
    Brown, David M.
    Brown, Andrea M.
    Edwards, Perry S.
    Liu, Zhiwen
    Philbrick, C. Russell
    JOURNAL OF APPLIED REMOTE SENSING, 2014, 8
  • [9] A long-path DOAS system using LED with stabilized spectrum as optical source for measuring atmospheric NO2
    Ling, Liu-Yi
    Lin, Pan-Pan
    Huang, You-Rui
    Xie, Pin-Hua
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2015, 26 (09): : 1712 - 1718
  • [10] The Detection of Atmospheric HONO and NO2 with Fiber Coupling Long-Path Differential Optical Absorption Spectroscopy System
    Duan Jun
    Qin Min
    Lu Xue
    Fang Wu
    Ling Liu-yi
    Wang Dan
    Shen Lan-lan
    Xie Pin-hua
    Liu Wen-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (07) : 2001 - 2005