Quantification of prefusion conformation for HIV vaccine using size-exclusion chromatography

被引:0
|
作者
Gollapudi, Deepika [1 ]
Shadrick, William [1 ]
Yang, Yanhong [1 ]
Gowetski, Daniel B. [1 ]
Gall, Jason [1 ]
Lei, Q. Paula [1 ]
机构
[1] NIAID, Vaccine Prod Program, VRC, NIH, 9 W Watkins Mill Rd, Gaithersburg, MD 20852 USA
基金
美国国家卫生研究院;
关键词
Trimer vaccine (T6931); Size-exclusion chromatography (SEC); Meso-scale diagnostics (MSD); Prefusion conformation; HIV; CAP256V2LS; ENVELOPE TRIMER;
D O I
10.1016/j.jchromb.2022.123296
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A closed prefusion conformation or an open (non-prefusion) conformational state of a protein vaccine candidate molecule can determine if it effectively elucidates a desired immunity. A quick and reliable method to monitor conformational state is important during vaccine development. In addition to our existing immunoassays, we have developed a unique physicochemical approach using size-exclusion chromatography to assess binding between antibody and the structurally desired antigen protein. Through the bound monoclonal antibody protein vaccine peak shift in the size-exclusion chromatography profile, this method determines the percent closed (prefusion) conformation present in a sample. Since only the closed prefusion conformation binds to the specific antibody, the population of the closed versus the open conformation of the vaccine molecule can be monitored without the need for a reference calibrator. This new method can be applied broadly to vaccine development, as well as for antibody selection during antibody drug discovery. The mAb CAP256V2LS (250 mu g/mL) specific to prefusion conformation was mixed with HIV trimer (250 mu g/mL) at 2:1 volume ratio, incubated at 37 degrees C for 30 mins and injected onto HPLC column. The percent of non-prefusion conformation was calculated based on ratio of peak area of unbound trimer and total area of control trimer sample (without mAb).
引用
收藏
页数:5
相关论文
共 50 条
  • [1] SIZE-EXCLUSION CHROMATOGRAPHY
    BARTH, HG
    BOYES, BE
    JACKSON, C
    ANALYTICAL CHEMISTRY, 1994, 66 (12) : R595 - R620
  • [2] Purification of bacteriocins using size-exclusion chromatography
    Rather, Irfan A.
    Hamad, Alshammari Fanar
    Bajpai, Vivek K.
    BANGLADESH JOURNAL OF PHARMACOLOGY, 2016, 11 (02) : 281 - 284
  • [3] Size distribution and chain conformation of six different fucoidans using size-exclusion chromatography with multiple detection
    Neupane, Sandesh
    Bittkau, Kaya Saskia
    Alban, Susanne
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1612
  • [4] Evaluation of size-exclusion chromatography and size-exclusion electrochromatography calibration curves
    Vander Heyden, Y
    Popovici, ST
    Schoenmakers, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) : 127 - 137
  • [5] AN OVERVIEW OF SIZE-EXCLUSION CHROMATOGRAPHY
    JOHNSON, JF
    PLASTICS ENGINEERING, 1983, 39 (03) : 50 - 50
  • [6] ALTERNATIVES TO SIZE-EXCLUSION CHROMATOGRAPHY
    REVILLON, A
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (14-15): : 2991 - 3023
  • [7] Size-exclusion chromatography - Foreword
    Heftmann, E
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2003, 56 (1-3): : VII - VII
  • [8] Inverse Size-Exclusion Chromatography
    Sepsey, Annamaria
    Bacskay, Ivett
    Felinger, Attila
    ADVANCES IN CHROMATOGRAPHY, VOL 55, 2018, 55 : 205 - 227
  • [9] Size and conformation of Ficoll as determined by size-exclusion chromatography followed by multiangle light scattering
    Fissell, William H.
    Hofmann, Christina L.
    Smith, Ross
    Chen, Michelle H.
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2010, 298 (01) : F205 - F208
  • [10] Longitudinal diffusion in size-exclusion chromatography: a stop-flow size-exclusion chromatography study
    Striegel, AM
    JOURNAL OF CHROMATOGRAPHY A, 2001, 932 (1-2) : 21 - 31